Free-Breathing 3D T1-Weighted Gradient-Echo Sequence With Radial Data Sampling in Abdominal MRI: Preliminary Observations

被引:69
|
作者
Azevedo, Rafael M. [1 ]
de Campos, Rafael O. P. [1 ]
Ramalho, Miguel [1 ]
Heredia, Vasco [1 ]
Dale, Brian M. [2 ]
Semelka, Richard C. [1 ]
机构
[1] Univ N Carolina, Dept Radiol, Chapel Hill, NC 27599 USA
[2] Siemens Healthcare, Cary, NC USA
关键词
3D gradient-echo sequence; abdominal MRI; free breathing; radial acquisition; uncooperative patient; K-SPACE; HEPATOCELLULAR-CARCINOMA; LIVER; RECONSTRUCTION; ABDOMEN;
D O I
10.2214/AJR.10.5881
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The purposes of this study were to evaluate the feasibility of a free-breathing 3D gradient-recalled echo sequence with radial data sampling (radial 3D GRE) in abdominal MRI compared with a standard 3D GRE volumetric interpolated breath-hold examination (VIBE) sequence for imaging of cooperative patients and to perform a preliminary assessment in imaging of noncooperative patients. MATERIALS AND METHODS. Fifty-five consecutively registered patients who underwent unenhanced and contrast-enhanced abdominal MRI with the free-breathing radial 3D GRE technique constituted the study population. Two readers independently and blindly evaluated the images. RESULTS. Overall image quality with the contrast-enhanced radial 3D GRE sequence was lower than but rated at least nearly as good as that with the 3D GRE VIBE sequence (p < 0.0001). Higher scores were recorded for 3D GRE VIBE images with respect to pixel graininess, streaking artifact, and sharpness (p = 0.0009 to p < 0.0001). Except for sharpness of vessels on unenhanced images, results for the radial 3D GRE sequence did not differ significantly in the comparison of cooperative and noncooperative patients (p = 0.004). For imaging of noncooperative patients, radial 3D GRE images of children had higher ratings for shading (unenhanced, p = 0.0004; contrast-enhanced, p < 0.0001) and streaking artifacts on contrast-enhanced images (p = 0.0017) than did those of adults. Overall image quality was higher for pediatric patients. In lesion analysis, use of the 3D GRE VIBE sequence was associated with significantly greater detectability, confidence, and conspicuity than was use of the radial 3D GRE sequence (p = 0.00026-0.011). CONCLUSION. A free-breathing radial 3D GRE sequence is feasible for abdominal MRI and may find application in imaging of patients who are unable to suspend respiration, especially children.
引用
收藏
页码:650 / 657
页数:8
相关论文
共 50 条
  • [21] Evaluation of a free-breathing respiratory-triggered (Navigator) 3-D T1-weighted (T1W) gradient recalled echo sequence (LAVA) for detection of enhancement in cystic and solid renal masses
    Wendy Tu
    Abdulrahman Alzahrani
    Stephen Currin
    Cindy Walsh
    Sabarish Narayanasamy
    Matthew D. F. McInnes
    Nicola Schieda
    European Radiology, 2019, 29 : 2507 - 2517
  • [22] Evaluation of Fetal Thyroid with 3D Gradient Echo T1-weighted MR Imaging
    Fujii, Shinya
    Nagaishi, Junichi
    Mukuda, Naoko
    Kaneda, Sachi
    Inoue, Chie
    Fukunaga, Takeru
    Ogawa, Toshihide
    MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2017, 16 (03) : 203 - 208
  • [23] Evaluation of a free-breathing respiratory-triggered (Navigator) 3-D T1-weighted (T1W) gradient recalled echo sequence (LAVA) for detection of enhancement in cystic and solid renal masses
    Tu, Wendy
    Alzahrani, Abdulrahman
    Currin, Stephen
    Walsh, Cindy
    Narayanasamy, Sabarish
    McInnes, Matthew D. F.
    Schieda, Nicola
    EUROPEAN RADIOLOGY, 2019, 29 (05) : 2507 - 2517
  • [24] OPTIMIZATION OF 3-DIMENSIONAL T1-WEIGHTED GRADIENT-ECHO IMAGING OF THE CERVICAL-SPINE
    ROSS, JS
    TKACH, JA
    DILLINGER, J
    RUGGIERI, PM
    MASARYK, TJ
    MODIC, MT
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1992, 2 (03): : 359 - 364
  • [25] Magnetic resonance imaging of the brain with gadopentetate dimeglumine-DTPA: Comparison of T1-weighted spin-echo and 3D gradient-echo sequences
    Li, DB
    Haacke, EM
    Tarr, RW
    Venkatesan, R
    Lin, WL
    Wielopolski, P
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1996, 6 (03): : 415 - 424
  • [26] MR imaging of coronary arteries: noncontrast free-breathing whole heart acquisition with ultrafast 3D balanced gradient-echo technique
    Auger, F.
    Willoteaux, S.
    Lions, C.
    Negaiwi, Z.
    Gengler, L.
    Midulla, M.
    Akkari, K.
    Beregi, J. P.
    JOURNAL DE RADIOLOGIE, 2010, 91 (01): : 78 - 81
  • [27] Detection of structural lesions of the sacroiliac joints in patients with spondyloarthritis: A comparison of T1-weighted 3D spoiled gradient echo MRI and MRI-based synthetic CT versus T1-weighted turbo spin echo MRI
    Krabbe, Simon
    Moller, Jakob M.
    Hadsbjerg, Anna E. F.
    Ewald, Anne
    Hangaard, Stine
    Pedersen, Susanne J.
    Ostergaard, Mikkel
    SKELETAL RADIOLOGY, 2024, 53 (11) : 2459 - 2468
  • [28] Short echo-time 3D radial gradient-echo MRI using concurrent dephasing and excitation
    Park, Jang-Yeon
    Moeller, Steen
    Goerke, Ute
    Auerbach, Edward
    Chamberlain, Ryan
    Ellermann, Jutta
    Garwood, Michael
    MAGNETIC RESONANCE IN MEDICINE, 2012, 67 (02) : 428 - 436
  • [29] Fat-Suppressed 3D T1-Weighted Gradient-Echo Imaging of the Cartilage With a Volumetric Interpolated Breath-Hold Examination
    Zheng, Zhuo-Zhao
    Shan, Han
    Li, Xuan
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 194 (05) : W414 - W419
  • [30] Reconstruction of undersampled radial free-breathing 3D abdominal MRI using stacked convolutional auto-encoders
    Lv, Jun
    Chen, Kun
    Yang, Ming
    Zhang, Jue
    Wang, Xiaoying
    MEDICAL PHYSICS, 2018, 45 (05) : 2023 - 2032