Improvement of non-contact measurement of propagation characteristics in tissues using pass-through airborne ultrasound

被引:0
|
作者
Hirata, Shinnosuke [1 ]
Terashima, Koichi [1 ]
Hachiya, Hiroyuki [1 ]
机构
[1] Tokyo Inst Technol, Dept Syst & Control Engn, Meguro Ku, Tokyo 1528550, Japan
关键词
WAVE-PROPAGATION; BONE; MODEL;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Measurement and evaluation of ultrasonic propagation characteristics in cancellous bone is one of the diagnosis methods of osteoporosis. Non-contact measurement of propagation characteristics in a heel using airborne ultrasound which passed through the heel has been proposed. The pass-through ultrasound is extremely attenuated due to large reflections at boundaries between air and heel surfaces. In the proposed method, therefore, the signal-to-noise ratio of the pass-through ultrasound is greatly improved by pulse compression using an higher-order M-sequence. Furthermore, the pass-through ultrasound also inflects at the boundaries. Therefore, the direction of the ultrasonic beam varies depending on the shape of the heel. In this paper, a method for reception of the pass-through ultrasound by considering inflections at the boundaries is described.
引用
收藏
页数:2
相关论文
共 50 条
  • [41] Non-contact strip speed measurement using electrostatic sensors
    Yan, Yong
    Xie, Zizhuo
    Krabicka, Jan
    Shao, Jiaqing
    2010 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE I2MTC 2010, PROCEEDINGS, 2010,
  • [42] An automated non-contact wall temperature measurement using thermoreflectance
    Shedd, TA
    Anderson, BW
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2005, 16 (12) : 2483 - 2488
  • [43] Non-contact measurement of respiratory cycles using a microphone array
    Miwa M.
    Uchida M.
    Artificial Life and Robotics, 2018, 23 (2) : 255 - 260
  • [44] NON-CONTACT METHOD FOR LENGTH MEASUREMENT USING DOPPLER EFFECT
    ZERVOS, P
    PTB-MITTEILUNGEN, 1978, 88 (03): : 193 - 197
  • [45] Non-contact measurement of ocular microtremor using laser speckle
    Kenny, E.
    Coakley, D.
    Boyle, G.
    BIOPHOTONICS: PHOTONIC SOLUTIONS FOR BETTER HEALTH CARE II, 2010, 7715
  • [46] Non-contact Measurement of Permittivity and Thickness Using Planar Resonators
    2015 IEEE MTT-S INTERNATIONAL MICROWAVE SYMPOSIUM (IMS), 2015,
  • [47] NON-CONTACT PULSE RATE MEASUREMENT USING FACIAL VIDEOS
    Ruba, M.
    Jeyakumar, Vijay
    Gurucharan, M. K.
    Kousika, V
    Viveka, S.
    PROCEEDINGS OF 2020 IEEE INTERNATIONAL CONFERENCE ON ADVANCES AND DEVELOPMENTS IN ELECTRICAL AND ELECTRONICS ENGINEERING (ICADEE), 2020, : 180 - 185
  • [48] New Approach for Non-Contact Measurement Using Vision Probe
    Costa, P. B.
    Baldner, F. O.
    Gomes, J. F. S.
    Barros, W. S.
    Leta, F. R.
    3RD INTERNATIONAL CONGRESS ON MECHANICAL METROLOGY (CIMMEC2014), 2015, 648
  • [49] Sleep/wake measurement using a non-contact biomotion sensor
    de Chazal, Philip
    Fox, Niall
    O'Hare, Emer
    Heneghan, Conor
    Zaffaroni, Alberto
    Boyle, Patricia
    Smith, Stephanie
    O'Connell, Caroline
    McNicholas, Walter T.
    JOURNAL OF SLEEP RESEARCH, 2011, 20 (02) : 356 - 366
  • [50] Non-contact fast Mueller matrix measurement system for investigation of bio-tissues
    Fricke, Dierk
    Becker, Alexander
    Juette, Lennart
    Wollweber, Merve
    Glasmacher, Birgit
    Roth, Bernhard
    PHOTONICS IN DERMATOLOGY AND PLASTIC SURGERY 2020, 2020, 11211