A rapid approach for quantitative magnetization transfer imaging in thigh muscles using the pulsed saturation method

被引:22
|
作者
Li, Ke [1 ,2 ]
Dortch, Richard D. [1 ,2 ,3 ]
Kroop, Susan F. [4 ]
Huston, Joseph W. [4 ]
Gochberg, Daniel F. [1 ,2 ,5 ]
Park, Jane H. [1 ,2 ,6 ]
Damon, Bruce M. [1 ,2 ,3 ,6 ]
机构
[1] Vanderbilt Univ, Inst Imaging Sci, Nashville, TN 37232 USA
[2] Vanderbilt Univ, Dept Radiol & Radiol Sci, Nashville, TN 37232 USA
[3] Vanderbilt Univ, Dept Biomed Engn, Nashville, TN 37232 USA
[4] Vanderbilt Univ, Dept Rheumatol, Nashville, TN 37232 USA
[5] Vanderbilt Univ, Dept Phys & Astron, Nashville, TN 37232 USA
[6] Vanderbilt Univ, Dept Mol Physiol & Biophys, Nashville, TN 37232 USA
关键词
Inflammatory myopathies; Polymyositis; Muscle disease; Quantitative magnetization transfer; MRI; Biomarker; PARAMETRIC MRI CHARACTERIZATION; IN-VIVO MT; SKELETAL-MUSCLE; HUMAN BRAIN; INVERSION-RECOVERY; MYELIN CONTENT; SPINAL-CORD; RELAXATION; SEQUENCES; EXCHANGE;
D O I
10.1016/j.mri.2015.03.003
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Quantitative magnetization transfer (qMT) imaging in skeletal muscle may be confounded by intramuscular adipose components, low signal-to-noise ratios (SNRs), and voluntary and involuntary motion artifacts. Collectively, these issues could create bias and error in parameter fitting. In this study, technical considerations related to these factors were systematically investigated, and solutions were proposed. First, numerical simulations indicate that the presence of an additional fat component significantly underestimates the pool size ratio (F). Therefore, fat-signal suppression (or water-selective excitation) is recommended for qMT imaging of skeletal muscle. Second, to minimize the effect of motion and muscle contraction artifacts in datasets collected with a conventional 14-point sampling scheme, a rapid two-parameter model was adapted from previous studies in the brain and spinal cord. The consecutive pair of sampling points with highest accuracy and precision for estimating F was determined with numerical simulations. Its performance with respect to SNR and incorrect parameter assumptions was systematically evaluated. QMT data fitting was performed in healthy control subjects and polymyositis patients, using both the two- and five-parameter models. The experimental results were consistent with the predictions from the numerical simulations. These data support the use of the two-parameter modeling approach for qMT imaging of skeletal muscle as a means to reduce total imaging time and/or permit additional signal averaging. (C) 2015 Elsevier Inc. All rights reserved.
引用
收藏
页码:709 / 717
页数:9
相关论文
共 50 条
  • [21] Uniform magnetization transfer in chemical exchange saturation transfer magnetic resonance imaging
    Jae-Seung Lee
    Prodromos Parasoglou
    Ding Xia
    Alexej Jerschow
    Ravinder R. Regatte
    Scientific Reports, 3
  • [22] Quantitative imaging of magnetization transfer exchange and relaxation properties in vivo using MRI
    Sled, JG
    Pike, GB
    MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (05) : 923 - 931
  • [23] Reliable Assessment of Swine Renal Fibrosis Using Quantitative Magnetization Transfer Imaging
    Jiang, Kai
    Ferguson, Christopher M.
    Grimm, Roger C.
    Zhu, Xiangyang
    Glockner, James F.
    Lerman, Lilach O.
    INVESTIGATIVE RADIOLOGY, 2022, 57 (05) : 334 - 342
  • [24] Quantitative magnetization transfer imaging of rodent glioma using selective inversion recovery
    Xu, Junzhong
    Li, Ke
    Zu, Zhongliang
    Li, Xia
    Gochberg, Daniel F.
    Gore, John C.
    NMR IN BIOMEDICINE, 2014, 27 (03) : 253 - 260
  • [25] Rapid and quantitative chemical exchange saturation transfer (CEST) imaging with magnetic resonance fingerprinting (MRF)
    Cohen, Ouri
    Huang, Shuning
    McMahon, Michael T.
    Rosen, Matthew S.
    Farrar, Christian T.
    MAGNETIC RESONANCE IN MEDICINE, 2018, 80 (06) : 2449 - 2463
  • [26] Estimation of magnetization transfer rates from PACE experiments with pulsed RF saturation
    Ropele, S
    Stollberger, R
    Hartung, HP
    Fazekas, F
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2000, 12 (05) : 749 - 756
  • [27] Quantitative magnetization transfer imaging of the human locus coeruleus
    Trujillo, Paula
    Petersen, Kalen J.
    Cronin, Matthew J.
    Lin, Ya-Chen
    Kang, Hakmook
    Donahue, Manus J.
    Smith, Seth A.
    Claassen, Daniel O.
    NEUROIMAGE, 2019, 200 : 191 - 198
  • [28] Pulsed magnetization transfer contrast for MR imaging with application to breast
    Santyr, GE
    Kelcz, F
    Schneider, E
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1996, 6 (01): : 203 - 212
  • [29] Rapid whole-brain quantitative magnetization transfer imaging using 3D selective inversion recovery sequences
    Cronin, Matthew J.
    Xu, Junzhong
    Bagnato, Francesca
    Gochberg, Daniel F.
    Gore, John C.
    Dortch, Richard D.
    MAGNETIC RESONANCE IMAGING, 2020, 68 : 66 - 74
  • [30] Erratum: Uniform magnetization transfer in chemical exchange saturation transfer magnetic resonance imaging
    Jae-Seung Lee
    Prodromos Parasoglou
    Ding Xia
    Alexej Jerschow
    Ravinder R. Regatte
    Scientific Reports, 3