Performance Evaluation of a Magnetically Actuated Capsule Microrobotic System for Medical Applications

被引:28
|
作者
Fu, Qiang [1 ,2 ]
Zhang, Songyuan [3 ]
Guo, Shuxiang [4 ,5 ]
Guo, Jian [1 ,2 ]
机构
[1] Tianjin Univ Technol, Tianjin Key Lab Control Theory & Applicat Complic, Binshui Xidao 391, Tianjin 300384, Peoples R China
[2] Tianjin Univ Technol, Sch Elect & Elect Engn, Biomed Robot Lab, Binshui Xidao 391, Tianjin 300384, Peoples R China
[3] Harbin Inst Technol, State Key Lab Robot & Syst, Harbin 150001, Heilongjiang, Peoples R China
[4] Beijing Inst Technol, Inst Adv Biomed Engn Syst, Key Lab Convergence Med Engn Syst & Healthcare Te, Minist Ind & Informat Technol,Sch Life Sci, Beijing 100081, Peoples R China
[5] Kagawa Univ, Fac Engn, Takamatsu, Kagawa 7610396, Japan
来源
MICROMACHINES | 2018年 / 9卷 / 12期
关键词
magnetic actuated capsule microrobotic system; magnetically actuated hybrid microrobot; rotational magnetic field plane; magnetic field changing frequency; DESIGN; ROBOT;
D O I
10.3390/mi9120641
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The paper aims to propose a magnetic actuated capsule microrobotic system, which is composed of a magnetically actuated microrobot with a screw jet mechanism, a driving system, and a positioning system. The magnetically actuated microrobot embedded an O-ring magnet as an actuator has potential for achieving a particular task, such as medical diagnose or drug delivery. The driving system composes of a three axes Helmholtz coils to generate a rotational magnetic field for controlling the magnetically actuated microrobot to realize the basic motion in pipe, e.g., forward/backward motion and upward/downward motion. The positioning system is used to detect the pose of the magnetically actuated microrobot in pipe. We will discuss the shape of the Helmholtz coils and the magnetic field around the O-ring magnet to obtain an optimal performance of the magnetically actuated microrobot. The experimental result indicated that the microrobot with screw jet motion has a flexible movement in pipe by adjusting the rotational magnetic field plane and the magnetic field changing frequency.
引用
收藏
页数:16
相关论文
共 50 条
  • [41] Magnetically actuated hydrogel-based capsule microrobots for intravascular targeted drug delivery
    Qiao, Shishuai
    Ouyang, Hangkong
    Zheng, Xiaoguang
    Qi, Chongwen
    Ma, Li
    JOURNAL OF MATERIALS CHEMISTRY B, 2023, 11 (26) : 6095 - 6105
  • [42] A new class of magnetically actuated pumps and valves for microfluidic applications
    Hamilton, Joshua K.
    Bryan, Matthew T.
    Gilbert, Andrew D.
    Ogrin, Feodor Y.
    Myers, Thomas O.
    SCIENTIFIC REPORTS, 2018, 8
  • [43] Magnetically actuated micro-manipulators for biological and biomedical applications
    Cao, J.
    Samad, I.
    Coombs, T. A.
    2008 3RD IEEE INTERNATIONAL CONFERENCE ON NANO/MICRO ENGINEERED AND MOLECULAR SYSTEMS, VOLS 1-3, 2008, : 708 - 711
  • [44] Magnetically Actuated Droplet Manipulation and Its Potential Biomedical Applications
    Huang, Guoyou
    Li, Moxiao
    Yang, Qingzhen
    Li, Yuhui
    Liu, Hao
    Yang, Hui
    Xu, Feng
    ACS APPLIED MATERIALS & INTERFACES, 2017, 9 (02) : 1155 - 1166
  • [45] A new class of magnetically actuated pumps and valves for microfluidic applications
    Joshua K. Hamilton
    Matthew T. Bryan
    Andrew D. Gilbert
    Feodor Y. Ogrin
    Thomas O. Myers
    Scientific Reports, 8
  • [46] Recent Advances in Magnetically Actuated Droplet Manipulation for Biomedical Applications
    Li, Jiaqi
    Su, Kaixin
    Liu, Hailan
    Zou, Yuan
    MAGNETOCHEMISTRY, 2024, 10 (04)
  • [47] Movement Characteristics Evaluation of the Spherical Robot Actuated by the Magnetic Field for Medical Applications
    Guo, Shuxiang
    Liang, Nan
    Guo, Jian
    Liu, Pengyu
    Wang, Lili
    Sun, Gang
    2016 IEEE INTERNATIONAL CONFERENCE ON MECHATRONICS AND AUTOMATION, 2016, : 448 - 453
  • [48] Robustness Evaluation of Internal Model Principle-based Controller in a Magnetically Actuated Surgical System
    Leong, F.
    Mohammadi, A.
    Tan, Y.
    Thiruchelvam, D.
    Valdastri, P.
    Oetomo, D.
    2018 AUSTRALIAN & NEW ZEALAND CONTROL CONFERENCE (ANZCC), 2018, : 257 - 262
  • [49] Evaluation of the performance of the video capsule system for screening of the stomach
    Adler, S
    Fireman, T
    GASTROINTESTINAL ENDOSCOPY, 2003, 57 (05) : AB167 - AB167
  • [50] Magnetically actuated artificial cilia for optimum mixing performance in microfluidics
    Chen, Chia-Yuan
    Chen, Chia-Yun
    Lin, Cheng-Yi
    Hu, Ya-Ting
    LAB ON A CHIP, 2013, 13 (14) : 2834 - 2839