Temperature analysis of 3D-printed biomaterials during unipolar and bipolar radiofrequency ablation procedure

被引:5
|
作者
Cappello, Ida Anna [1 ]
Candelari, Mara [1 ]
Pannone, Luigi [1 ]
Monaco, Cinzia [1 ]
Bori, Edoardo [2 ]
Talevi, Giacomo [1 ]
Ramak, Robbert [1 ]
La Meir, Mark [3 ]
Gharaviri, Ali [1 ]
Chierchia, Gian Battista [1 ]
Innocenti, Bernardo [2 ]
de Asmundis, Carlo [1 ]
机构
[1] Vrije Univ Brussel, Universitair Ziekenhuis Brussel, Heart Rhythm Management Ctr, Postgrad Program Cardiac Electrophysiol & Pacing,E, Brussels, Belgium
[2] Univ Libre Bruxelles, BEAMS Dept Bio Electro & Mech Syst, Brussels, Belgium
[3] Vrije Univ Brussel, Universitair Ziekenhuis Brussel, Cardiac Surg Dept, Brussels, Belgium
来源
关键词
biomaterial tests; thermal test; radiofrequency ablation; 3D surgical guide; arrhythmias treatment;
D O I
10.3389/fcvm.2022.978333
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BackgroundDue to their mechanical properties, the MED625FLX and TPU95A could be appropriate candidates for cardiac 3D surgical guide use during radiofrequency ablation (RFA) treatment. MethodsRFA aims to destroy the heart tissue, which cause arrhythmias, by applying a radiofrequency (RF) energy at critical temperature above +50.0 degrees C, where the thermal damage is considered not reversible. This study aims to analyze the biomaterials thermal properties with different thicknesses, by testing the response to bipolar and unipolar RFA on porcine muscle samples (PMS), expressed in temperature. For the materials evaluation, the tissue temperature during RFA applications was recorded, firstly without (control) and after with the biomaterials in position. The biomaterials were considered suitable for the RFA treatment if: (1) the PMS temperatures with the samples were not statistically different compared with the control; (2) the temperatures never reached the threshold; (3) no geometrical changes after RFA were observed. ResultsBased on these criteria, none of the tested biomaterials resulted appropriate for unipolar RFA and the TPU95A failed almost all thermal tests also with the bipolar RFA. The 1.0 mm MED625FLX was modified by bipolar RFA in shape, losing its function. Instead, the 2.5 mm MED625FLX was considered suitable for bipolar RFA catheter use only. ConclusionsThe 2.5 mm MED625FLX could be used, in the design of surgical guides for RFA bipolar catheter only, because of mechanical, geometrical, and thermal properties. None of biomaterials tested are appropriate for unipolar ablation catheter because of temperature concerns. Further investigations for clinical use are eagerly awaited.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] ARRHYTHMIAS DURING UNIPOLAR AND BIPOLAR RADIOFREQUENCY CATHETER ABLATION IN THE CANINE VENTRICLE
    FRANKLIN, JO
    OEFF, M
    LANGBERG, JJ
    HERRE, JM
    GRIFFIN, JC
    CHIN, MC
    SCHEINMAN, MM
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1988, 11 (04): : 489 - 489
  • [2] Editorial: 3D-printed biomaterials in osteochondral repair
    Zhou, Changchun
    Li, Lan
    Jia, Xiaofeng
    Zhang, Lei
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2022, 10
  • [3] 3D-Printed Biomaterials for Guided Tissue Regeneration
    Zhang, Ben
    Song, Jie
    SMALL METHODS, 2018, 2 (09):
  • [4] 3D-printed biomaterials with regional auxetic properties
    Warner, John J.
    Gillies, Allison R.
    Hwang, Henry H.
    Zhang, Hong
    Lieber, Richard L.
    Chen, Shaochen
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2017, 76 : 145 - 152
  • [5] Cardiac Radiofrequency Ablation Simulation Using a 3D-Printed Bi-Atrial Thermochromic Model
    Wang, Shu
    Saija, Carlo
    Choo, Justin
    Ou, Zhanchong
    Birsoan, Maria
    Germanos, Sarah
    Rothwell, Joshua
    Vakili, Behrad
    Kotadia, Irum
    Xu, Zhouyang
    Rolet, Adrian
    Namour, Adriana
    Yang, Woo Suk
    Williams, Steven E.
    Rhode, Kawal
    APPLIED SCIENCES-BASEL, 2022, 12 (13):
  • [6] BIOMATERIALS New 3D-printed muscle is the strong, sensitive type
    Harwitz, Emily
    CHEMICAL & ENGINEERING NEWS, 2021, 99 (27) : 11 - 11
  • [7] Evaluating 3D-Printed Biomaterials as Scaffolds for Vascularized Bone Tissue Engineering
    Wang, Martha O.
    Vorwald, Charlotte E.
    Dreher, Maureen L.
    Mott, Eric J.
    Cheng, Ming-Huei
    Cinar, Ali
    Mehdizadeh, Hamidreza
    Somo, Sami
    Dean, David
    Brey, Eric M.
    Fisher, John P.
    ADVANCED MATERIALS, 2015, 27 (01) : 138 - 144
  • [8] Performance and Limitations of 3D-Printed Bipolar Plates in Fuel Cells
    Gould, Benjamin D.
    Rodgers, Joseph A.
    Schuette, Michael
    Bethune, Keith
    Louis, Shaquille
    Rocheleau, Richard
    Swider-Lyons, Karen
    ECS JOURNAL OF SOLID STATE SCIENCE AND TECHNOLOGY, 2015, 4 (04) : P3063 - P3068
  • [9] A 3D-printed surgical guide for ischemic scar targeting and ablation
    Candelari, Mara
    Cappello, Ida Anna
    Pannone, Luigi
    Monaco, Cinzia
    Talevi, Giacomo
    Bori, Edoardo
    Ramak, Robbert
    La Meir, Mark
    Gharaviri, Ali
    Chierchia, Gian Battista
    Innocenti, Bernardo
    de Asmundis, Carlo
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2022, 9
  • [10] Stochastic or deterministic: Duality of fatigue behaviour of 3D-printed meta-biomaterials
    Zhang, Jieming S.
    Liu, Huifang
    Tang, Yuanbo T.
    Deng, Yun
    Kuek, Nicole
    Lui, Andrew
    Grant, Patrick S.
    Alabort, Enrique
    Reed, Roger C.
    Cocks, Alan C. F.
    MATERIALS & DESIGN, 2024, 245