A preliminary study of few-view image reconstruction of sparse objects in cone-beam micro-CT

被引:0
|
作者
Han, Xiao [1 ]
Bian, Junguo [1 ]
Eaker, Diane R. [2 ]
Sidky, Emil Y. [1 ]
Ritman, Erik L. [2 ]
Pan, Xiaochuan [1 ]
机构
[1] Univ Chicago, Dept Radiol, Chicago, IL 60637 USA
[2] Mayo Clin Coll Med, Dept Physiol & Biomed Engn, Rochester, MN 55905 USA
关键词
few-view image reconstruction; micro-CT; COMPUTED-TOMOGRAPHY;
D O I
10.1117/12.845320
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Micro-CT enables convenient visualization and quantitative analysis of small animals and biological data from hundreds of view angles. This prolonged imaging process limits system throughput and may cause potential radiation damage to the imaged objects. It is therefore desirable to have a technique which can generate volume images with satisfactory quality, but from a smaller amount of projection data. On the other hand, many objects subject to the micro-CT scans have sparse spatial distribution, and this sparcity could be exploited and incorporated as prior knowledge in innovative design of algorithms that are capable of reconstructing images from few-view projection data. In this work we applied a new iterative algorithm based upon constrained total-variation minimization to reconstructing images from as few as five projections. Preliminary results suggest that the algorithm can yield potentially useful images from substantially less projection data than required by existing algorithms. This has practical implications of reducing scanning time and minimizing radiation damage to the imaged objects.
引用
收藏
页数:4
相关论文
共 50 条
  • [21] Simulation of mechanical misalignments in a cone-beam micro-CT system
    Vidal-Migallon, I.
    Abella, M.
    Sisniega, A.
    Vaquero, J. J.
    Desco, M.
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 4273 - 4275
  • [22] Effect of the data constraint on few-view, fan-beam CT image reconstruction by TV minimization
    Sidky, Emil Y.
    Kao, Chien-Min
    Pan, Xiaochuan
    2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 2296 - 2298
  • [23] Cone-Beam CT Reconstruction with Deformed Prior Image
    Zhang, H.
    Ouyang, L.
    Huang, J.
    Ma, J.
    Chen, W.
    Wang, J.
    MEDICAL PHYSICS, 2014, 41 (06) : 527 - 527
  • [24] Cone-Beam CT Image Reconstruction with Spherical Harmonics
    Shimomura, T.
    Haga, A.
    MEDICAL PHYSICS, 2020, 47 (06) : E391 - E392
  • [25] A case of true concrescence diagnosed with cone-beam CT and in vivo micro-CT
    Ono, Masamichi
    Shimizu, Osamu
    Ueda, Koichiro
    Hashimoto, Junko
    Shiratsuchi, Hiroshi
    Yonehara, Yoshiyuki
    Honda, Kazuya
    ORAL RADIOLOGY, 2010, 26 (02) : 106 - 109
  • [26] An Improved Helical Cone-beam CT Image Reconstruction
    Gao, Yang
    Ma, Jianhua
    Chen, Wufan
    2009 3RD INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOMEDICAL ENGINEERING, VOLS 1-11, 2009, : 2178 - 2182
  • [27] A case of true concrescence diagnosed with cone-beam CT and in vivo micro-CT
    Masamichi Ono
    Osamu Shimizu
    Koichiro Ueda
    Junko Hashimoto
    Hiroshi Shiratsuchi
    Yoshiyuki Yonehara
    Kazuya Honda
    Oral Radiology, 2010, 26 : 106 - 109
  • [28] Comparison of fan-beam, cone-beam and spiral scan reconstruction for x-ray micro-CT
    Sasov, A
    MEDICAL IMAGING 2001: PHYSICS OF MEDICAL IMAGING, 2001, 4320 : 711 - 718
  • [29] A few-view reweighted sparsity hunting (FRESH) method for CT image reconstruction
    Chang, Ming
    Li, Liang
    Chen, Zhiqiang
    Xiao, Yongshun
    Zhang, Li
    Wang, Ge
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2013, 21 (02) : 161 - 176
  • [30] Comparison of fan-beam, cone-beam and spiral scan reconstruction in X-ray micro-CT
    Sasov, A
    DEVELOPMENTS IN X-RAY TOMOGRAPHY III, 2002, 4503 : 124 - 131