Measurement of Cs-135/Cs-137 isotope ratio by quadrupole mass analyzer

被引:0
|
作者
Nakamura, S [1 ]
Harada, H [1 ]
Katoh, T [1 ]
机构
[1] Power Reactor & Nucl Fuel Dev Corp, Tokai, Ibaraki, Japan
关键词
D O I
暂无
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
In order to measure the neutron capture cross section of Cs-135, a quadrupole mass analyzer was developed. With 0.3 mu g of CsCl sample containing Cs-135 and Cs-137 isotopes, the isotope ratio of Cs-135/Cs-137 has been measured with an accuracy of the 3% total error.
引用
收藏
页码:1341 / 1343
页数:3
相关论文
共 50 条