An image registration based ultrasound probe calibration

被引:1
|
作者
Li, Xin [1 ]
Kumar, Dinesh [1 ]
Sarkar, Saradwata [1 ]
Narayanan, Ram [1 ]
机构
[1] Eigen, Grass Valley, CA 95945 USA
来源
关键词
Image Registration; Ultrasound Probe Calibration;
D O I
10.1117/12.911461
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Reconstructed 3D ultrasound of prostate gland finds application in several medical areas such as image guided biopsy, therapy planning and dose delivery [1]. In our application, we use an end-fire probe rotated about its axis to acquire a sequence of rotational slices to reconstruct 3D TRUS (Transrectal Ultrasound) image. The image acquisition system consists of an ultrasound transducer situated on a cradle directly attached to a rotational sensor. However, due to system tolerances, axis of probe does not align exactly with the designed axis of rotation resulting in artifacts in the 3D reconstructed ultrasound volume. We present a rigid registration based automatic probe calibration approach. The method uses a sequence of phantom images, each pair acquired at angular separation of 180 degrees and registers corresponding image pairs to compute the deviation from designed axis. A modified shadow removal algorithm is applied for preprocessing. An attribute vector is constructed from image intensity and a speckle-insensitive information-theoretic feature. We compare registration between the presented method and expert-corrected images in 16 prostate phantom scans. Images were acquired at multiple resolutions, and different misalignment settings from two ultrasound machines. Screenshots from 3D reconstruction are shown before and after misalignment correction. Registration parameters from automatic and manual correction were found to be in good agreement. Average absolute differences of translation and rotation between automatic and manual methods were 0.27 mm and 0.65 degree, respectively. The registration parameters also showed lower variability for automatic registration (pooled standard deviation sigma(translation) = 0.50 mm, sigma(rotation) = 0.52 degree) compared to the manual approach (pooled standard deviation sigma(translation) = 0.62 mm, sigma(rotation) = 0.78 degree).
引用
收藏
页数:8
相关论文
共 50 条
  • [21] REGISTRATION OF ULTRASOUND IMAGE SEQUENCES FOR PERFUSION ANALYSIS
    Harabis, Vratislav
    Kolar, Radim
    Jirik, Radovan
    19TH EUROPEAN SIGNAL PROCESSING CONFERENCE (EUSIPCO-2011), 2011, : 1015 - 1019
  • [22] Image-enhanced endoscopy calibration and image registration accuracy testing
    Bax, MR
    Khadem, R
    Johnson, JA
    Wilkinson, EP
    Shahidi, R
    MEDICAL IMAGING 2002: VISUALIZATION, IMAGE-GUIDED PROCEDURES, AND DISPLAY, 2002, 4681 : 119 - 126
  • [23] A novel ultrasound probe calibration method for multimodal image guidance of needle placement in cervical cancer brachytherapy
    Pu, Gang
    Jiang, Shan
    Yang, Zhiyong
    Hu, Yuanjing
    Liu, Ziqi
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2022, 100 : 81 - 89
  • [24] A Literature Survey of Ultrasound and Computed Tomography-Based Cardiac Image Registration
    Ming, Chieng Thion
    Omar, Zaid
    Mahmood, Nasrul Humaimi
    Kadiman, Suhaini
    JURNAL TEKNOLOGI, 2015, 74 (06): : 93 - 101
  • [25] Geometry Based Transperineal Ultrasound Probe Positioning for Image Guided Radiotherapy
    Camps, S.
    Verhaegen, F.
    de With, P.
    Fontanarosa, D.
    MEDICAL PHYSICS, 2016, 43 (06) : 3671 - 3671
  • [26] A novel ultrasound probe calibration method for multimodal image guidance of needle placement in cervical cancer brachytherapy
    Pu, Gang
    Jiang, Shan
    Yang, Zhiyong
    Hu, Yuanjing
    Liu, Ziqi
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2022, 100 : 81 - 89
  • [27] Deep Learning-Based Fetal Development Ultrasound Image Segmentation and Registration
    Zhou, Yang
    Cao, Chuang
    TRAITEMENT DU SIGNAL, 2023, 40 (01) : 343 - 349
  • [28] System architecture for intraoperative ultrasound registration in image-based medical navigation
    Dekomien, Claudia
    Roeschies, Benjamin
    Winter, Susanne
    BIOMEDICAL ENGINEERING-BIOMEDIZINISCHE TECHNIK, 2012, 57 (04): : 229 - 237
  • [29] Image-based registration of ultrasound and magnetic resonance images: A preliminary study
    Pagoulatos, N
    Haynor, DR
    Kim, Y
    MEDICAL IMAGING 2000: IMAGE DISPLAY AND VISUALIZATION, 2000, 3976 : 156 - 164
  • [30] Image-based Co-Registration of Angiography and Intravascular Ultrasound Images
    Wang, Peng
    Ecabert, Olivier
    Chen, Terrence
    Wels, Michael
    Rieber, Johannes
    Ostermeier, Martin
    Comaniciu, Dorin
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2013, 32 (12) : 2238 - 2249