An image registration based ultrasound probe calibration

被引:1
|
作者
Li, Xin [1 ]
Kumar, Dinesh [1 ]
Sarkar, Saradwata [1 ]
Narayanan, Ram [1 ]
机构
[1] Eigen, Grass Valley, CA 95945 USA
来源
关键词
Image Registration; Ultrasound Probe Calibration;
D O I
10.1117/12.911461
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Reconstructed 3D ultrasound of prostate gland finds application in several medical areas such as image guided biopsy, therapy planning and dose delivery [1]. In our application, we use an end-fire probe rotated about its axis to acquire a sequence of rotational slices to reconstruct 3D TRUS (Transrectal Ultrasound) image. The image acquisition system consists of an ultrasound transducer situated on a cradle directly attached to a rotational sensor. However, due to system tolerances, axis of probe does not align exactly with the designed axis of rotation resulting in artifacts in the 3D reconstructed ultrasound volume. We present a rigid registration based automatic probe calibration approach. The method uses a sequence of phantom images, each pair acquired at angular separation of 180 degrees and registers corresponding image pairs to compute the deviation from designed axis. A modified shadow removal algorithm is applied for preprocessing. An attribute vector is constructed from image intensity and a speckle-insensitive information-theoretic feature. We compare registration between the presented method and expert-corrected images in 16 prostate phantom scans. Images were acquired at multiple resolutions, and different misalignment settings from two ultrasound machines. Screenshots from 3D reconstruction are shown before and after misalignment correction. Registration parameters from automatic and manual correction were found to be in good agreement. Average absolute differences of translation and rotation between automatic and manual methods were 0.27 mm and 0.65 degree, respectively. The registration parameters also showed lower variability for automatic registration (pooled standard deviation sigma(translation) = 0.50 mm, sigma(rotation) = 0.52 degree) compared to the manual approach (pooled standard deviation sigma(translation) = 0.62 mm, sigma(rotation) = 0.78 degree).
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Ultrasound calibration using intensity-based image registration: For application in cardiac catheterization procedures
    Ma, Y. L.
    Rhode, K. S.
    Gao, G.
    King, A. P.
    Chinchapatnam, P.
    Schaeffter, T.
    Hawkes, D. J.
    Razavi, R.
    Penney, G. P.
    MEDICAL IMAGING 2008: VISUALIZATION, IMAGE-GUIDED PROCEDURES, AND MODELING, PTS 1 AND 2, 2008, 6918
  • [2] An image registration approach to automated calibration for freehand 3D ultrasound
    Blackall, JM
    Rueckert, D
    Maurer, CR
    Penney, GP
    Hill, DLG
    Hawkes, DJ
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2000, 2000, 1935 : 462 - 471
  • [3] Automatic 3D ultrasound calibration for image guided therapy using intramodality image registration
    Schlosser, Jeffrey
    Kirmizibayrak, Can
    Shamdasani, Vijay
    Metz, Steve
    Hristov, Dimitre
    PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (21): : 7481 - 7496
  • [4] Robot-assisted ultrasound probe calibration for image-guided interventions
    Paralikar, Atharva
    Mantripragada, Pavan
    Nguyen, Trong
    Arjoune, Youness
    Shekhar, Raj
    Monfaredi, Reza
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2025,
  • [5] A fast and accurate method of ultrasound probe calibration for image-guided surgery
    Welch, JN
    Bax, M
    Mori, K
    Krummel, T
    Shahidi, R
    Maurer, CR
    CARS 2002: COMPUTER ASSISTED RADIOLOGY AND SURGERY, PROCEEDINGS, 2002, : 1078 - 1078
  • [6] A method for ultrasound probe calibration based on arbitrary wire phantom
    Shen, Chunxu
    Lyu, Liushuai
    Wang, Guangzhi
    Wu, Jian
    COGENT ENGINEERING, 2019, 6 (01):
  • [7] Calibration and Registration for Inspection Robot with Contact Probe
    Chen, Yuqing
    Huang, Jin
    Xu, Huipu
    Ma, Zi
    MANUFACTURING SCIENCE AND ENGINEERING, PTS 1-5, 2010, 97-101 : 4319 - 4323
  • [8] Quantitative Assessments for Ultrasound Probe Calibration
    Chen, Elvis C. S.
    Ma, Burton
    Peters, Terry M.
    MEDICAL IMAGE COMPUTING AND COMPUTER ASSISTED INTERVENTION - MICCAI 2021, PT IV, 2021, 12904 : 363 - 372
  • [9] 4D Ultrasound Calibration for Radiotherapy Guidance Using Automatic Intramodality Image Registration
    Schlosser, J.
    Kirmizibayrak, C.
    Shamdasani, V.
    Metz, S.
    Hristov, D.
    MEDICAL PHYSICS, 2012, 39 (06) : 3617 - 3617
  • [10] Bone registration using a robotic ultrasound probe
    Torres, Pedro M. B.
    Goncalves, Paulo J. S.
    Martins, Jorge M. M.
    COMPUTATIONAL VISION AND MEDICAL IMAGE PROCESSING: VIPIMAGE 2011, 2012, : 79 - 83