Quantitative Evaluation of Real-Time Shear-Wave Elastography under Deep Learning in Children with Chronic Kidney Disease

被引:1
|
作者
Zhang, Jie [1 ]
Duan, Cuirong [2 ]
Duan, Xingxing [1 ]
Hu, Yuan [1 ]
Liu, Jinqiao [1 ]
Chen, Wenjuan [1 ]
机构
[1] Hunan Childrens Hosp, Dept Ultrasound, Changsha 410007, Hunan, Peoples R China
[2] Hunan Childrens Hosp, Dept Renal Rheumatol, Changsha 410007, Hunan, Peoples R China
关键词
Elastic moduli;
D O I
10.1155/2022/6051695
中图分类号
TP31 [计算机软件];
学科分类号
081202 ; 0835 ;
摘要
Objective. This research was to study the application value of real-time shear wave elastography (SWE) quantitative evaluation based on deep learning (DL) in the diagnosis of chronic kidney disease (CKD) in children. Methods. 60 children with pathological diagnoses of CKD were selected as a CKD group. During the same period, 45 healthy children for physical examination were selected as the control group. The application value of real-time shear-wave elastography based on DL in the evaluation of CKD in children was explored by comparing the differences between the two groups. Results. It was found that the elastic modulus values of the middle and lower parenchyma of the left kidney and right kidney in the case group were (22.02 +/- 10.98) kPa and (21.99 +/- 11.87) kPa, respectively, which were substantially higher compared with (4.61 +/- 0.47) kPa and (4.50 +/- 0.59) kPa in the control group. Young's modulus (YM) of the middle and lower parenchyma of the left kidney in patients with CKD stages 3 to 5 was 13.27 +/- 0.83, 24.21 +/- 5.69, and 31.67 +/- 3.82, respectively, and that of the right kidney was 17.26 +/- 0.98, 26.76 +/- 7.22, and 32.37 +/- 4.27, respectively, and the difference was significant (P < 0.05). In patients with moderate and severe CKD, the YM values of the middle and lower parenchyma of the left kidney were 17.27 +/- 0.83, 27.93 +/- 6.49, and those of the right kidney were 17.26 +/- 0.98, 29.56 +/- 6.49, respectively, and the difference was statistically significant ( P < 0.05).,e serum creatinine (Scr) of the CKD group was substantially higher than that of the control group, and the estimated glomerular filtration rate (eGFR) level of the former was lower than that of the latter. However, there was no statistical difference between the YM values of the middle and lower parts of the left and right kidneys of the CKD group and the control group. Conclusion. The DL-based SWE is a new noninvasive, real-time, and quantitative detection method, which can effectively evaluate the stiffness of the kidney and help to better detect the progress of CKD as a clinical reference.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Diagnostic value of real-time shear wave elastography in children with chronic kidney disease
    Liu, Qin
    Wang, Zhengrong
    [J]. CLINICAL HEMORHEOLOGY AND MICROCIRCULATION, 2021, 77 (03) : 287 - 293
  • [2] Viscoelasticity in Achilles Tendonopathy: Quantitative Assessment by Using Real-time Shear-Wave Elastography
    Aubry, Sebastien
    Nueffer, Jean-Philippe
    Tanter, Mickael
    Becce, Fabio
    Vidal, Chrystelle
    Michel, Fabrice
    [J]. RADIOLOGY, 2015, 274 (03) : 821 - 829
  • [3] Prostate Cancer: Diagnostic Performance of Real-time Shear-Wave Elastography
    Correas, Jean-Michel
    Tissier, Anne-Marie
    Khairoune, Ahmed
    Vassiliu, Viorel
    Mejean, Arnaud
    Helenon, Olivier
    Memo, Richard
    Barr, Richard G.
    [J]. RADIOLOGY, 2015, 275 (01) : 280 - 289
  • [4] Viscoelasticity in trapezius myofascial pain syndrome: quantitative assessment using Real-Time Shear-Wave Elastography
    Hao, Chang-Juan
    Xiao, Wen-Li
    Zhang, Quan-Bin
    Tan, Xiao-Mei
    [J]. ANNALS OF MEDICINE, 2023, 55 (02)
  • [5] Determination of Normal Hepatic Elasticity by Using Real-time Shear-wave Elastography
    Suh, Chong Hyun
    Kim, So Yeon
    Kim, Kyoung Won
    Lim, Young-Suk
    Lee, So Jung
    Lee, Moon-Gyu
    Lee, JungBok
    Lee, Sung-Gyu
    Yu, Eunsil
    [J]. RADIOLOGY, 2014, 271 (03) : 895 - 900
  • [6] Shear wave elastography evaluation of cats with chronic kidney disease
    Appleby, Ryan B.
    Vaden, Shelly L.
    Monteith, Gabrielle
    Seiler, Gabriela S.
    [J]. VETERINARY RADIOLOGY & ULTRASOUND, 2023, 64 (02) : 330 - 336
  • [7] Association of renal elasticity evaluated by real-time shear wave elastography with renal fibrosis in patients with chronic kidney disease
    Chen, Ziman
    Wang, Yingli
    Ying, Michael Tin Cheung
    Su, Zhongzhen
    Han, Xinyang
    Gunda, Simon Takadiyi
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2024, 97 (1154): : 392 - 398
  • [8] Reproducibility of real-time shear wave elastography in the evaluation of liver elasticity
    Ferraioli, Giovanna
    Tinelli, Carmine
    Zicchetti, Mabel
    Above, Elisabetta
    Poma, Gianluigi
    Di Gregorio, Marta
    Filice, Carlo
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (11) : 3102 - 3106
  • [9] Deep learning based classification of breast tumors with shear-wave elastography
    Zhang, Qi
    Xiao, Yang
    Dai, Wei
    Suo, Jingfeng
    Wang, Congzhi
    Shi, Jun
    Zheng, Hairong
    [J]. ULTRASONICS, 2016, 72 : 150 - 157
  • [10] Transvaginal Real-time Shear Wave Elastography in the Diagnosis of Cervical Disease
    Liu, Chun
    Li, Ting Ting
    Hu, Ziyue
    Li, Yuan
    Cheng, Xueqing
    Zhu, Yi
    Lu, Man
    [J]. JOURNAL OF ULTRASOUND IN MEDICINE, 2019, 38 (12) : 3173 - 3181