Peripheral and Low Doses Measurement for Three Stereotactic Radiotherapy Techniques

被引:0
|
作者
Ammar, H. [1 ]
机构
[1] Childrens Canc Hosp Egypt 57357, Radiotherapy, Cairo, Egypt
关键词
D O I
暂无
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
PD-125
引用
收藏
页码:S90 / S91
页数:2
相关论文
共 50 条
  • [1] Measurement of the peripheral doses for linac stereotactic radiotherapy
    Majali, M
    Novotny, J
    Novotny, J
    RADIATION PROTECTION DOSIMETRY, 2003, 106 (03) : 247 - 252
  • [2] Are three doses of stereotactic ablative radiotherapy (SABR) more effective than 30 doses of conventional radiotherapy?
    Simeonova, Anna O.
    Fleckenstein, Katharina
    Wertz, Hansjorg
    Frauenfeld, Anian
    Boda-Heggemann, Judit
    Lohr, Frank
    Wenz, Frederik
    TRANSLATIONAL LUNG CANCER RESEARCH, 2012, 1 (01) : 45 - 53
  • [3] DOSIMETRIC COMPARISON OF THREE TECHNIQUES FOR SPINE STEREOTACTIC BODY RADIOTHERAPY
    Aljabab, Saif
    Vellayappan, Balamurugan
    Vandervoort, Eric
    Bahm, Jamie
    Zohr, Robert
    Sinclair, John
    Szanto, Janos
    Malone, Shawn
    RADIOTHERAPY AND ONCOLOGY, 2016, 120 : S93 - S93
  • [4] Doses to organs at risk for conformational and stereotactic radiotherapy: Bladder
    Duverge, L.
    Castelli, J.
    Lizee, T.
    de Crevoisier, R.
    Azria, D.
    CANCER RADIOTHERAPIE, 2017, 21 (6-7): : 597 - 603
  • [5] Extracranial doses in stereotactic and conventional radiotherapy for pituitary adenomas
    Ram, Thomas Samuel
    Ravindran, Paul B.
    Viswanathan, Faith R.
    Viswanathan, Perungulam Narayan
    Pavamani, Simon P.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2006, 7 (02): : 96 - 100
  • [6] CHARACTERISATION OF PERIPHERAL DOSES FROM STEREOTACTIC PHOTON FIELDS
    Taylor, M.
    McDermott, L.
    Johnston, P.
    Ackerly, T.
    Kron, T.
    Franich, R.
    RADIOTHERAPY AND ONCOLOGY, 2009, 92 : S94 - S94
  • [7] Uncertainties in the measurement of relative doses in radiotherapy
    Bulinski, Krzysztof
    Kuszewski, Tomasz
    Wnuk, Katarzyna
    Braziewicz, Janusz
    Slosarek, Krzysztof
    POLISH JOURNAL OF MEDICAL PHYSICS AND ENGINEERING, 2021, 27 (01): : 1 - 9
  • [9] Low and medium doses of hypofractionated stereotactic radiotherapy could be suboptimal for early-stage lung cancer
    Maranzano, Ernesto
    Draghini, Lorena
    Rossi, Romina
    Casale, Michelina
    Trippa, Fabio
    JOURNAL OF RADIOSURGERY AND SBRT, 2013, 2 (03): : 243 - 250
  • [10] Stereotactic body radiotherapy (SBRT) for peripheral lung tumors. A comparison of two VMAT delivery techniques
    Penedo Cobos, J.
    Garcia Castejon, M. A.
    Perez Casas, A. M.
    Gomez Tejedor, S.
    Rincon Perez, M.
    Prieto Munoz, I.
    Luna Tirado, J.
    Olivera Vegas, J.
    Vara Cantos, J.
    RADIOTHERAPY AND ONCOLOGY, 2015, 115 : S773 - S773