Retention parameters in chromatography (IUPAC recommendations 2001)

被引:61
|
作者
Domínguez, JAG
Díez-Masa, JC
Davankov, VA
机构
[1] CSIC, Inst Phys Chem Rocasolano, Madrid 28006, Spain
[2] CSIC, Inst Organ Chem, Madrid 28006, Spain
[3] Russian Acad Sci, AN Nesmeyanov Organoelement Cpds Inst, Moscow 119991, Russia
关键词
D O I
10.1351/pac200173060969
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The paper presents a revision of terms in the IUPAC "Nomenclature for Chromatography", Pure and Applied Chemistry, 65, 819-872, 1993. The terms revised pertain to hold-up volumes in gas, liquid, and supercritical-fluid chromatography, as well as to basic retention parameters, especially in gas chromatography. A number of related and derived definitions are described, including definitions of the terms "chromatographic process" and "chromatographic phase system". A number of the original terms were found to be misleading or superfluous, including such terms as corrected retention time, net retention time, total retention volume (time), and specific retention volume at 0 degreesC, and their use is strongly discouraged. In Part A, the concept of the hold-up volume in chromatography is discussed. The paper also compares methods described in the literature to determine the hold-up volume. In Part B, retention parameters in gas chromatography are discussed with the aim of (i) emphasizing the physical meaning of the terms and (ii) specifying the temperatures and pressures for the terms for gas volumes and flow rates. The appendix presents revised recommendations for the terminology of some items, as well as those that are not recommended.
引用
收藏
页码:969 / 992
页数:24
相关论文
共 50 条
  • [41] Numbering of fullerenes - (IUPAC Recommendations 2005)
    Cozzi, F
    Powell, WH
    Thilgen, C
    PURE AND APPLIED CHEMISTRY, 2005, 77 (05) : 843 - 923
  • [42] IUPAC RECOMMENDATIONS ON NOMENCLATURE AND SYMBOLS - SYNOPSIS
    BUC, RP
    CHEMIA ANALITYCZNA, 1993, 38 (04): : 553 - 553
  • [43] Compendium of chemical terminology (IUPAC recommendations)
    Aran Redo, Vicente J.
    PANACEA-BOLETIN DE MEDICINA Y TRADUCCION, 2005, 6 (21-22): : 429 - 430
  • [44] Guidelines for the representation of pulse sequences for solution-state nuclear magnetic resonance spectrometry - (IUPAC recommendations 2001)
    Davies, AN
    Lambert, J
    Lancashire, RJ
    Lampen, P
    Conover, W
    Frey, M
    Grzonka, M
    Williams, E
    Meinhart, D
    PURE AND APPLIED CHEMISTRY, 2001, 73 (11) : 1749 - 1764
  • [45] Extension of ThermoML: The IUPAC standard for thermodynamic data communications (IUPAC Recommendations 2011)
    Frenkel, Michael
    Chirico, Robert D.
    Diky, Vladimir
    Brown, Paul L.
    Dymond, John H.
    Goldberg, Robert N.
    Goodwin, Anthony R. H.
    Heerklotz, Heiko
    Koenigsberger, Erich
    Ladbury, John E.
    Marsh, Kenneth N.
    Remeta, David P.
    Stein, Stephen E.
    Wakeham, William A.
    Williams, Peter A.
    PURE AND APPLIED CHEMISTRY, 2011, 83 (10) : 1937 - 1969
  • [46] Definitions of basic terms relating to low-molar-mass and polymer liquid crystals -: (IUPAC recommendations 2001)
    Barón, M
    PURE AND APPLIED CHEMISTRY, 2001, 73 (05) : 845 - 895
  • [47] Accuracy of retention model parameters obtained from retention data in liquid chromatography
    Brau, Tyler
    Pirok, Bob
    Rutan, Sarah
    Stoll, Dwight
    JOURNAL OF SEPARATION SCIENCE, 2022, 45 (17) : 3241 - 3255
  • [48] On the interrelation between the Henry constant and retention parameters in chromatography
    Larin, A. V.
    COLLOID JOURNAL, 2011, 73 (06) : 856 - 858
  • [49] On the interrelation between the Henry constant and retention parameters in chromatography
    A. V. Larin
    Colloid Journal, 2011, 73 : 856 - 858