Validated Stability Indicating LC Method for Carprofen: Characterization of Degradation Products by MS

被引:5
|
作者
Tele, Shahaji S. [1 ,2 ]
Gadkari, Tushar V. [2 ]
Patil, Shivajirao R. [1 ]
Kolekar, Govind B. [1 ]
机构
[1] Shivaji Univ, Dept Chem, Kolhapur 416004, MS, India
[2] Sai Advantium Pharma Ltd, Pune 411057, Maharashtra, India
关键词
PHOTOLYSIS; NSAIDS;
D O I
10.1093/chrsci/49.6.434
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A simple, sensitive, and selective stability indicating highperformance liquid chromatographic method has been developed and validated for quantitative analysis of carprofen (CPF) in presence of its degradation products. All degradation products in acid hydrolysis and photolysis were separated, identified by mass spectroscopic method and probable structures were elucidated. The forced degradation studies were performed on a bulk sample of CPF by using various methods like 0.1 M hydrochloric acid, 0.1 M sodium hydroxide, 0.33% hydrogen peroxide (H2O2), heating at 60°C and exposure to UV light at 254 nm. A 5 μm particle octa desyl silane (ODS) column (150 mm x 4.6 mm) was used with acetonitrile-ammonium acetate (100 mM, pH-6.7) 40:60 (v/v) as a mobile phase at flow rate of 1.2 mL/min. Column oven temperature was maintained at 30°C and quantitation was achieved at 239 nm on the basis of peak area. The linear range and correlation coefficient (r2) was found 0.5-60 μg/mL and 0.9999 respectively. The limit of detection (LOD) and limit of quantitation (LOQ) were obtained 0.066 μg/mL and 0.20 μg/mL respectively. The proposed method was found to be suitable and accurate for quantitative analysis, stability study and characterisation of degradation product of CPF.
引用
收藏
页码:434 / 438
页数:5
相关论文
共 50 条
  • [31] A stability-indicating LC-MS/MS method for zidovudine: Identification, characterization and toxicity prediction of two major acid degradation products
    Devrukhakar, Prashant S.
    Shankar, M. Shiva
    Shankar, G.
    Srinivas, R.
    JOURNAL OF PHARMACEUTICAL ANALYSIS, 2017, 7 (04) : 231 - 236
  • [32] ESI-MSn and LC-ESI-MS studies to characterize forced degradation products of bosentan and a validated stability-indicating LC-UV method
    Bansal, Gulshan
    Singh, Ranjit
    Saini, Balraj
    Bansal, Yogita
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2013, 72 : 186 - 197
  • [33] Development of a stability-indicating HPLC method for Lasmiditan and its process related impurities with characterization of degradation products by LC-MS/MS
    Reddy, Cherukula Srinivasa
    Babu, Chilakabattina Naga Narasimha
    Tatavarti, Bhagya Kumar
    Vijaya, Nalleboyina
    Anna, Venkateswara Rao
    JOURNAL OF CHEMICAL METROLOGY, 2023, 17 (01): : 79 - 92
  • [34] LC-MS/MS characterization of forced degradation products of ambrisentan: development and validation of a stability-indicating RP-HPLC method
    Ramisetti, Nageswara Rao
    Kuntamukkala, Ramakrishna
    NEW JOURNAL OF CHEMISTRY, 2014, 38 (07) : 3050 - 3061
  • [35] Study of forced degradation behavior of enalapril maleate by LC and LC-MS and development of a validated stability-indicating assay method
    Bhardwaj, Sunny Piyush
    Singh, Saranjit
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2008, 46 (01) : 113 - 120
  • [36] Development of Validated Stability Indicating Method for Estimation of Vandetanib and Characterization of its Degradants by LC-ESI-MS
    Salode, Vikrant Liladhar
    Game, Madhuri Deorao
    Salode, Gouri Vikrant
    Gadge, Sonali Suresh
    INDIAN JOURNAL OF PHARMACEUTICAL EDUCATION AND RESEARCH, 2022, 56 (01) : 232 - 239
  • [37] Stability indicating LC-MS/MS method and validation of Selexipag impurities and identification of its force degradation products
    Shah, Pranavkumar
    Hadiyal, Sanjay
    Dhaduk, Bhavin
    RESULTS IN CHEMISTRY, 2023, 6
  • [38] Degradation kinetics study of cabozantinib by a novel stability-indicating LC method and identification of its major degradation products by LC/TOF-MS and LC-MS/MS
    Wu, Chunyong
    Xu, Xue
    Feng, Chao
    Shi, Yuanyuan
    Liu, Wenyuan
    Zhu, Xiaoyun
    Zhang, Junying
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2014, 98 : 356 - 363
  • [39] A Validated Stability-Indicating LC Method for Zonisamide
    Dnyandeo B. Pathare
    Ashok S. Jadhav
    Murlidhar S. Shingare
    Chromatographia, 2007, 66 : 945 - 947
  • [40] Development of a Validated Stability Indicating LC Method for Lamotrigine
    Srinivasulu, Polisetty
    Mukkanti, Khagga
    Reguri, Buchi Reddy
    Srinivas, Koduri S. V.
    CHROMATOGRAPHIA, 2009, 70 (1-2) : 271 - 276