Experimental and numerical analysis of solar-absorbing metallic facade panel with embedded heat-pipe-array

被引:11
|
作者
Liu, Wenjie [1 ,2 ]
Chow, Tin-Tai [1 ,2 ]
机构
[1] City Univ Hong Kong, Div Bldg Sci & Technol, Hong Kong, Peoples R China
[2] City Univ Hong Kong, Shenzhen Res Inst, Hong Kong, Peoples R China
关键词
Solar-absorbing facade; Heat-pipe technology; Curtain wall; Solar energy utilization; Sustainable building; SEASON PERFORMANCE; ENERGY-CONSUMPTION; HOT-WATER; OPTIMIZATION; APPLICABILITY; COLLECTOR;
D O I
10.1016/j.apenergy.2020.114736
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The integrative performance of advanced building facade is important for sustainable building development. This paper introduces two solar-absorbing curtain-wall panels with embedded straight-heat-pipe and heat-pipe-ring respectively. Taking advantage of the high thermal conductance of heat pipe, the proposed solar-absorbing aluminum panels can preheat cold water, like for the domestic hot water supply. They also reduce the solar transmission to the indoor space. In hot summer, the dual effect leads to considerable energy saving in both the hot-water and the air-conditioning systems. Comparing with the water-tubing collector panel, the heat-pipe type has wider application by eliminating the water-freezing problem. The conceptual design, prototype construction and computer-model development of these two panels are discussed in this paper. Measurements were taken with the two prototypes installed at an outdoor environmental chamber. Dynamic simulation models were then developed through the control volume finite difference method, and validated with the measured data. The simulation models can be used in advanced building simulation tools for transient thermal performance analysis. Further numerical analysis with these models showed that comparatively, the innovative heat-pipe-ring is the more promising design because of the effective increase in solar absorbing surface area. In the studied warm climate scenarios from summer to winter and from sunny to cloudy conditions, the water heat gain efficiency was estimated from 62.5% to 94.9% in all cases with the glazed panel. The estimated room heat gain/loss as well as the electricity saving performance are also attractive.
引用
收藏
页数:13
相关论文
共 50 条
  • [31] Experimental study of the thermal characteristics of a heat storage wall with micro-heat pipe array (MHPA) and PCM in solar greenhouse
    Guan, Yong
    Meng, Qi
    Ji, Tianxu
    Hu, Wanling
    Li, Wenlong
    Liu, Tianming
    ENERGY, 2023, 264
  • [32] NUMERICAL AND EXPERIMENTAL ANALYSIS OF HEAT AND MASS TRANSFER FOR A PASSIVE SOLAR GREENHOUSE
    Zhang Linhua
    Liu Shan
    Chang Lina
    Zhang Feng
    PROCEEDINGS OF THE FIRST INTERNATIONAL CONFERENCE ON SUSTAINABLE URBANIZATION (ICSU 2010), 2010, : 764 - 771
  • [33] Numerical and experimental Analysis of Solar Injera Baking with a PCM Heat Storage
    Tesfay, Asfafaw H.
    Kahsay, Mulu B.
    Nydal, Ole J.
    MOMONA ETHIOPIAN JOURNAL OF SCIENCE, 2019, 11 (01): : 1 - 13
  • [34] Numerical and Experimental Study on Energy Performance of Photovoltaic-Heat Pipe Solar Collector in Northern China
    Chen, Hongbing
    Chen, Xilin
    Chu, Sai
    Zhang, Lei
    Xiong, Yaxuan
    INTERNATIONAL JOURNAL OF PHOTOENERGY, 2015, 2015
  • [35] Experimental and numerical study on a novel low temperature facade solar thermal collector to decrease the heating demands: A south-north pipe-embedded closed-water-loop system
    Ibrahim, Mohamad
    Wurtz, Etienne
    Anger, Jocelyn
    Ibrahim, Oussama
    SOLAR ENERGY, 2017, 147 : 22 - 36
  • [36] Theoretical and experimental analysis of the thermal performance of a heat-pipe evacuated solar tube
    He, ZN
    HEAT TRANSFER SCIENCE AND TECHNOLOGY 2000, 2000, : 849 - 854
  • [37] An Experimental Analysis of Pipe Inspection using Solar Panel Receiver for Visible Light Communication and Energy Harvesting
    Zhao, Wen
    Kamezaki, Mitsuhiro
    Yamaguchi, Kaoru
    Konno, Minoru
    Onuki, Akihiko
    Sugano, Shigeki
    2020 IEEE/ASME INTERNATIONAL CONFERENCE ON ADVANCED INTELLIGENT MECHATRONICS (AIM), 2020, : 1848 - 1853
  • [38] Numerical analysis of solar ventilated facade integrated thermoelectric energy harvesting panel for simultaneous building thermal insulation and power generation
    Huang, Xiao-Yan
    He, Jian-Wei
    Huang, Ying-Xi
    Cai, Yang
    Wang, Wei-Wei
    Zhao, Fu-Yun
    JOURNAL OF BUILDING ENGINEERING, 2023, 76
  • [39] Performance analysis on a solar concentrating thermoelectric generator using the micro-channel heat pipe array
    Li, Guiqiang
    Zhang, Gan
    He, Wei
    Ji, Jie
    Lv, Song
    Chen, Xiao
    Chen, Hongbing
    ENERGY CONVERSION AND MANAGEMENT, 2016, 112 : 191 - 198
  • [40] Experimental and numerical analysis of a novel air-to-air heat recovery unit based on flat micro-heat pipe array technology for a laboratory animal house
    Wang, Mi
    Fan, Hongming
    Li, Jiatong
    SCIENCE AND TECHNOLOGY FOR THE BUILT ENVIRONMENT, 2022, 28 (03) : 391 - 402