Determining how to identify and manage indoor-air problems may appear straightforward. Instrumentation is nowadays capable of detecting pollutant concentrations at levels far below those considered to be a health hazard. Sophisticated, computer-controlled "smart" building systems are also available that enable parameters within large, multi-zone buildings to be set and maintained at required levels and that control other variables related to operating the buildings in response to outdoor climate. Buildings can also be designed so that indoor-air problems are prevented initially. Nevertheless, the frequency of media headlines on the consequences of indoor-air and indoor-environment problems indicates that much is still to be done in identifying and managing indoor-air deficiencies. This paper explores the causes behind indoor-air problems, particularly when measurements do not identify any problems and everything has been done properly. On the basis of the given illustrations, options for ensuring good air quality in complex and ever-changing indoor environments are discussed in this paper.
引用
收藏
页码:5 / 9
页数:5
相关论文
共 50 条
  • [11] CONCENTRATIONS OF TETRACHLOROETHYLENE IN INDOOR-AIR AND FOOD IN APARTMENTS IN THE VICINITY OF DRY CLEANING SHOPS
    REINHARD, K
    DULSON, W
    EXNER, M
    ZENTRALBLATT FUR HYGIENE UND UMWELTMEDIZIN, 1989, 189 (02): : 111 - 116
  • [12] A framework to interpret passively sampled indoor-air VOC concentrations in health studies
    Schlink, Uwe
    Roeder, Stefan
    Kohajda, Tibor
    Wissenbach, Dirk K.
    Franck, Ulrich
    Lehmann, Irina
    BUILDING AND ENVIRONMENT, 2016, 105 : 198 - 209
  • [13] Managing indoor air quality
    Mansdorf, Z
    ADVANCES IN FILTRATION AND SEPARATION TECHNOLOGY, VOLS 13A AND 13B, 1999: ADVANCING FILTRATION AND SEPARATION SOLUTIONS FOR THE MILLENNIUM, 1999, : 703 - 703
  • [14] Indoor-Air Quality Implications of 222RN from Lunar Regolith
    Levy, Francois
    Fardal, John Patrick
    LUNAR SETTLEMENTS, 2010, : 277 - 290
  • [15] Putting out fires: An examination of the determinants of state clean indoor-air laws
    Gallet, Craig A.
    Hoover, Gary A.
    Lee, Junsoo
    SOUTHERN ECONOMIC JOURNAL, 2006, 73 (01) : 112 - 124
  • [16] Determining the ventilation and aerosol deposition rates from routine indoor-air measurements
    Christos H. Halios
    Costas G. Helmis
    Katerina Deligianni
    Sterios Vratolis
    Konstantinos Eleftheriadis
    Environmental Monitoring and Assessment, 2014, 186 : 151 - 163
  • [17] Interventions for mitigating indoor-air pollution in Nigeria: a cost-benefit analysis
    Isihak, Salisu
    Akpan, Uduak
    Adeleye, Monsuru
    INTERNATIONAL JOURNAL OF ENERGY SECTOR MANAGEMENT, 2012, 6 (03) : 417 - 429
  • [18] A multivariable nonlinear MPC control strategy for thermal comfort and indoor-air quality
    del Mar Castilla, Maria
    Alvarez, Jose D.
    Normey-Rico, Julio E.
    Rodriguez, Francisco
    Berenguel, Manuel
    39TH ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY (IECON 2013), 2013, : 7908 - 7913
  • [19] Optimal control of indoor-air cooling in buildings using a reduced order model
    Ben Ayed, S.
    Kim, D.
    Borggaard, J. T.
    Cliff, E. M.
    ENERGY, 2016, 116 : 1191 - 1204
  • [20] Determining the ventilation and aerosol deposition rates from routine indoor-air measurements
    Halios, Christos H.
    Helmis, Costas G.
    Deligianni, Katerina
    Vratolis, Sterios
    Eleftheriadis, Konstantinos
    ENVIRONMENTAL MONITORING AND ASSESSMENT, 2014, 186 (01) : 151 - 163