Ultra-Highly Sensitive DNA Detection with Conducting Polymer-Modified Electrodes: Mechanism, Manufacture and Prospects for Rapid e-PCR

被引:1
|
作者
Zhu, Bicheng [1 ,2 ]
Kerr-Philips, Thomas [1 ]
Al Ghaus, Zahraa [1 ]
Chan, Eddie Wai Chi [1 ,2 ]
Barker, David [1 ,2 ]
Evans, Clive W. [1 ,2 ,3 ]
Williams, David E. [1 ,2 ]
Travas-Sejdic, Jadranka [1 ,2 ]
机构
[1] Univ Auckland, Polymer Biointerface Ctr, Sch Chem Sci, Auckland 1010, New Zealand
[2] Victoria Univ Wellington, MacDiarmid Inst Adv Mat & Nanotechnol, Laby Bldg Kelburn Campus, Wellington 6012, New Zealand
[3] Univ Auckland, Sch Biol Sci, Auckland 1010, New Zealand
关键词
LABEL-FREE; ELECTROCHEMICAL IMPEDANCE; CHARGE-TRANSFER; REAL-TIME; BIOSENSOR; SENSOR; HYBRIDIZATION; PROBE; OLIGONUCLEOTIDES; IMMUNOSENSOR;
D O I
10.1149/1945-7111/ac5ced
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
At low copy number, sequence detection by polymerase chain reaction (PCR) requires up to 30 cycles (amplification 10(9)) to produce a reliably detectable concentration of fluorescently-labelled amplicons. The cycle number and hence detection time is determined by the analytical sensitivity of the detector. Hybridisation of complementary DNA strands to oligonucleotide-modified conducting polymer electrodes yields an increase in the charge transfer resistance for the ferri-ferrocyanide redox couple. We demonstrate sensors using screen-printed carbon electrodes modified with a conducting polymer formed from a monomer pre-functionalised with complementary oligonucleotide, with pM sensitivity for short sequences and aM for bacterial lysate, with a response time-scale of 5 min. The response is due to the variation of electrical resistance within the polymer film. We develop a mechanism based on repulsion from the solution interface of dopant anions by the charge associated with surface-bound DNA. With results for >160 single-use sensors, we formulate a response model based on percolation within a random resistor network and highlight challenges for large-scale manufacture of such sensors. Such sensors used for label-free electrochemical detection for PCR (e-PCR) would decrease the required cycle number from 30 to less than 10 and would offer a much simplified instrument construction. (C) 2022 The Electrochemical Society ("ECS"). Published on behalf of ECS by IOP Publishing Limited.
引用
收藏
页数:13
相关论文
共 1 条
  • [1] Highly sensitive amperometric enzyme biosensor for detection of superoxide based on conducting polymer/CNT modified electrodes and superoxide dismutase
    Braik, Mourad
    Barsan, Madalina M.
    Dridi, Cherif
    Ben Ali, Mounir
    Brett, Christopher M. A.
    SENSORS AND ACTUATORS B-CHEMICAL, 2016, 236 : 574 - 582