Infrared Sensor Detection and Actuator Treatment Applied during Hemodialysis

被引:4
|
作者
Liou, Jian-Chiun [1 ]
Hsiao, Yu-Cheng [2 ]
Yang, Cheng-Fu [3 ]
机构
[1] Taipei Med Univ, Sch Biomed Engn, Taipei 11031, Taiwan
[2] Taipei Med Univ, Grad Inst Biomed Optomechatron, Taipei 11031, Taiwan
[3] Natl Univ Kaohsiung, Dept Chem & Mat Engn, Kaohsiung 811, Taiwan
关键词
near-infrared light; sensor; far-infrared radiation; actuator; physiologically;
D O I
10.3390/s20092521
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Infrared thermography can be applied in different medical systems, for example it can be used to catch the images of living blood vessels. Far infrared rays can be used in a heating machine, which can be applied in the clinical hemodialysis patients. Infrared electronically sensitized images, which are generated by near-infrared Charge-coupled Device (CCD), are used to detect blood vessels, and used as a long-wavelength external stimulating therapeutic tissue repair system. When an infrared sensor detection and actuator treatment is applied during hemodialysis, a missing needle can be detected, and far infrared rays have a therapeutic effect on blood vessels. Because a far-infrared actuated light source can improve blood circulation, it is currently used to prevent fistula embolism in hemodialysis (HD) patients and reduce vascular occlusion after hemodialysis. Sensors used for sudden changes in heart rate variability (HRV) are used as predictive and evaluation indicators for our new method. Far-infrared actuated radiation can increase sympathetic nerve activity and regulation of parasympathetic and sympathetic nerves. We performed baseline measurements of the low-frequency/high-frequency ratio of autonomic nerve activity before hemodialysis (low frequency (LF), high frequency (HF), LF/HF, before HD) and after hemodialysis (LF/HF, after-HD). Based on data from the HRV continuity tracking report, 35 patients with autonomic nerve activation were treated and evaluated. We have demonstrated that the resulting near-infrared (NIR) sensor imaging and far-infrared actuator illumination can be used for the detection and treatment of hemodialysis patients.
引用
收藏
页数:17
相关论文
共 50 条
  • [31] Dynamic Neural Network for Detection and Identification Actuator and Sensor Faults
    Dhaou, O.
    Sidhom, L.
    Abdelkrim, A.
    2018 INTERNATIONAL CONFERENCE ON ADVANCED SYSTEMS AND ELECTRICAL TECHNOLOGIES (IC_ASET), 2017, : 107 - 112
  • [32] Actuator and Sensor Fault Detection and Diagnosis for Unmanned Quadrotor Helicopters
    Zhong, Yujiang
    Zhang, Youmin
    Zhang, Wei
    Zhan, Hao
    IFAC PAPERSONLINE, 2018, 51 (24): : 998 - 1003
  • [33] A Decentralized Damage Detection System for Wireless Sensor and Actuator Networks
    Santos, Igor L.
    Pirmez, Luci
    Carmo, Luiz R.
    Pires, Paulo F.
    Delicato, Flavia C.
    Khan, Samee U.
    Zomaya, Albert Y.
    IEEE TRANSACTIONS ON COMPUTERS, 2016, 65 (05) : 1363 - 1376
  • [34] Detection and diagnosis of sensor and actuator failures using IMM estimator
    Zhang, YM
    Li, XR
    IEEE TRANSACTIONS ON AEROSPACE AND ELECTRONIC SYSTEMS, 1998, 34 (04) : 1293 - 1313
  • [35] Infrared hyperspectral imaging sensor for gas detection
    Hinnrichs, M
    IMAGING SPECTROMETRY VI, 2000, 4132 : 344 - 355
  • [36] Flexible Optoelectronic Organic Sensor for Infrared Detection
    Guedes, Andre F. S.
    Tartari, Simone
    INFRARED TECHNOLOGY AND APPLICATIONS XLVII, 2021, 11741
  • [37] Engineering Platform for Sensor and Actuator Concepts During Cockpit Development
    Budaker, Bernhard
    Geiger, Markus
    Seel, Albert
    Fernandes, Keane
    Husfeldt, Daniel
    Schueller, Simeon
    2019 IEEE INTERNATIONAL CONFERENCE ON CONSUMER ELECTRONICS (ICCE), 2019,
  • [38] COHERENT DETECTION APPLIED TO OPTICAL AND INFRARED ASTRONOMY - INTRODUCTION
    VANBUEREN, HG
    SPACE SCIENCE REVIEWS, 1975, 17 (05) : 621 - 628
  • [39] Detection of hypotension during hemodialysis using the ECG
    Solem, K
    Nilsson, A
    Sörnmo, L
    COMPUTERS IN CARDIOLOGY 2004, VOL 31, 2004, 31 : 717 - 720
  • [40] Infrared flash thermography applied to the external defect detection on HTR fuel particles during the manufacturing process
    Hermosilla-Lara, S.
    Piriou, M.
    Levesque, P.
    REVIEW OF PROGRESS IN QUANTITATIVE NONDESTRUCTIVE EVALUATION, VOL 27A AND 27B, 2008, 975 : 1659 - +