Evaluation of a Novel Light Scattering Methodology for the Detection of Pathogenic Bacteria in Urine

被引:3
|
作者
Davaro, Elizabeth [1 ]
Tomaras, Andrew P. [2 ]
Chamberland, Robin R. [1 ]
Isbella, T. Scott [1 ]
机构
[1] St Louis Univ, Sch Med, Dept Pathol, Div Clin Pathol, St Louis, MO 63104 USA
[2] BacterioScan Inc, St Louis, MO USA
来源
关键词
TRACT-INFECTIONS;
D O I
10.1093/jalm/jfz013
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: Urine culture, the gold standard for detecting and identifying bacteria in urine, is one of the highest volume tests in many microbiology laboratories. The inability to accurately predict which patients would benefit from culture leads not only to monopolization of laboratory resources, but also to unnecessary antimicrobial exposure as patients receive empirical treatment for suspected or presumed urinary tract infections (UTI) while awaiting culture results. A common approach to decrease unnecessary urine culture is screening samples using urinalysis (UA) parameters to determine those that should proceed to culture (reflex). In this study, we compared the performance of a novel uropathogen detection method to urinalysis for purposes of UTI screening. Methods: Urine specimens submitted for culture (n = 194) were evaluated by urinalysis and a novel light scattering device (BacterioScan 216Dx UTI System) capable of detecting the presence of bacteria in urine. Sensitivity and specificity for prediction of a positive urine culture by UA and 216Dx were determined relative to urine culture results. A positive urine culture was defined as growth in culture of one or two uropathogens at concentrations of >= 50,000 CFU/mL. Results: 194 urine samples were evaluated by UA, 216Dx, and urine culture. The 216Dx demonstrated a 100% [95%CI: 88.43%-100.0%] sensitivity and 81.71% [95%CI: 74.93%-87.30%] specificity for the detection of bacteriuria, vs UA with a sensitivity of 86.67% [95%CI 69.28%-96.24%] and specificity of 71.95% [95%CI: 64.41%-78.68%] when compared to urine culture (diagnostic reference method). Conclusions: BacterioScan allows for an alternative method of screening with satisfactory sensitivity and improved specificity that may facilitate a reduction of unnecessary cultures. Additional studies are required to determine if a concomitant decrease in inappropriate antibiotic use can be realized with the 216Dx technology.
引用
收藏
页码:370 / 376
页数:7
相关论文
共 50 条
  • [31] Electrochemical biosensors for the detection of pathogenic bacteria in food
    Riu, Jordi
    Giussani, Barbara
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2020, 126
  • [32] Rapid Detection of Pathogenic Bacteria by the Naked Eye
    Kandasamy, Karthikeyan
    Jannatin, Miftakhul
    Chen, Yu-Chie
    BIOSENSORS-BASEL, 2021, 11 (09):
  • [33] Application of Flow Cytometry to the Detection of Pathogenic Bacteria
    Kennedy, Deirdre
    Wilkinson, Martin G.
    CURRENT ISSUES IN MOLECULAR BIOLOGY, 2017, 23 : 21 - 38
  • [34] Rapid detection techniques of waterborne pathogenic bacteria
    Wen, Yi
    Zhu, Gang-Hui
    Gao, Zhi-Yun
    Wu, Yue-Ying
    Wu, Shun-Ze
    Diqiu Kexue - Zhongguo Dizhi Daxue Xuebao/Earth Science - Journal of China University of Geosciences, 2013, 38 (SUPPL.2): : 29 - 36
  • [35] Multimodal Plasmonic Nanosensor for the Detection of Pathogenic Bacteria
    Tay, Li-Lin
    Hulse, John
    Ryan, Shannon
    Tanha, Jamshid
    Fraser, Jeff
    Wu, Xiaohua
    BIOSENSING II, 2009, 7397
  • [36] Application of Fluorescence Nanomaterials in Pathogenic Bacteria Detection
    Zhao, Dan
    Wang, Changtao
    Su, Lei
    Zhang, Xueji
    PROGRESS IN CHEMISTRY, 2021, 33 (09) : 1482 - 1495
  • [37] Recent advances in dual recognition based surface enhanced Raman scattering for pathogenic bacteria detection: A review
    Wang, Panxue
    Sun, Yan
    Li, Xiang
    Wang, Li
    Xu, Ying
    He, Lili
    Li, Guoliang
    ANALYTICA CHIMICA ACTA, 2021, 1157
  • [38] Silver nanorod arrays as a surface-enhanced Raman scattering substrate for foodborne pathogenic bacteria detection
    Chu, Hsiaoyun
    Huang, Yaowen
    Zhao, Yiping
    APPLIED SPECTROSCOPY, 2008, 62 (08) : 922 - 931
  • [39] Visual Detection and Avoidance of Pathogenic Bacteria by Aphids
    Hendry, Tory A.
    Ligon, Russell A.
    Besler, Kevin R.
    Fay, Rachel L.
    Smee, Melanie R.
    CURRENT BIOLOGY, 2018, 28 (19) : 3158 - +
  • [40] Advances in Portable Visual Detection of Pathogenic Bacteria
    Wang, Kuiyu
    Wang, Zhenhao
    Zeng, Hui
    Luo, Xiliang
    Yang, Tao
    ACS APPLIED BIO MATERIALS, 2020, 3 (11): : 7291 - 7305