Isotope correlation technique for Pu mass analysis of PWR UO2 spent fuel rods

被引:0
|
作者
Seo, Hee [1 ]
Ahn, Seong-Kyu [1 ]
Han, Bo-Young [1 ]
Lee, Chaehun [1 ]
Shin, Hee-Sung [1 ]
Kim, Bong Young [1 ]
Lee, Seung Kyu [1 ]
Won, Byung-Hee [1 ]
Jo, Kwang Ho [1 ]
Kim, Ho-Dong [1 ]
Park, Geun-Il [1 ]
Park, Se-Hwan [1 ]
机构
[1] Korea Atom Energy Res Inst, Daejeon, South Korea
基金
新加坡国家研究基金会;
关键词
Safeguards; nuclear material accountancy; spent fuel; isotope correlation;
D O I
10.1080/00223131.2015.1137244
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
A simple and fast method of nuclear material accountancy of pressurized water reactor (PWR) UO2 spent fuel rods for safeguards application was developed utilizing the isotope correlation between the amounts of Cs-137 and total Pu. To this end, the following steps were taken: (1) as much destructive analysis (DA) data as possible for segments taken from a PWR UO2 spent fuel rod were aggregated from publicly available data sources; (2) the DA data were corrected so as to have the same cooling time (i.e., CT = 0 y) and analyzed for outliers; (3) an equation converting the Cs-137 amount to the Pu amount was obtained by regression analysis with logarithmic curve fitting; and (4) the error in determining the Pu amount was evaluated for the imposition of a limit on the range of burnup (BU) or initial enrichment (IE). It was found that the averaged % error in calibration was determined to be 3.88% +/- 2.68% (= mean +/- 1 standard deviation) for the BU range over 30GWd/tU and falling with increasing BU range. On the other hand, there was no benefit in applying the limit of the IE range. Lastly, the Pu-mass difference between various methods was compared and it was found that the difference can be incurred up to 11.4%, according to the choice of method. In conclusion, the proposed isotope correlation technique could be used for input material accountancy with reasonable uncertainty.
引用
收藏
页码:1563 / 1572
页数:10
相关论文
共 50 条
  • [21] TRANSIENT IRRADIATION EXPERIMENTS WITH VIBRATIONALLY COMPACTED UO2 FUEL RODS IN TREAT
    GULLEY, RL
    ARMSTRON.DR
    HARRISON, LJ
    TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1968, 11 (01): : 111 - &
  • [22] DENSITY AND MICROSTRUCTURE CHANGES IN UO2 FUEL THROUGH 3 CYCLES OF PWR IRRADIATION
    RIGDON, MA
    BAIN, GM
    AMERICAN CERAMIC SOCIETY BULLETIN, 1979, 58 (03): : 389 - 389
  • [23] IRRADIATION OF ZIRCALOY-2-CLAD FUEL RODS CONTAINING DISHED PELLET UO2 FUEL
    ROWLAND, TC
    TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1968, 11 (01): : 106 - &
  • [24] Effect of external gamma irradiation on dissolution of the spent UO2 fuel matrix
    Jégou, C
    Muzeau, B
    Broudic, V
    Peuget, S
    Poulesquen, A
    Roudil, D
    Corbel, C
    JOURNAL OF NUCLEAR MATERIALS, 2005, 341 (01) : 62 - 82
  • [25] Sensitivity and uncertainty analysis for UO2 and MOX fueled PWR cells
    Foad, Basma
    Takeda, Toshikazu
    ANNALS OF NUCLEAR ENERGY, 2015, 75 : 595 - 604
  • [26] MICROSTRUCTURAL AND DENSITY CHANGES IN UO2 FUEL AFTER ONE CYCLE OF PWR OPERATION
    RIGDON, MA
    AMERICAN CERAMIC SOCIETY BULLETIN, 1977, 56 (03): : 342 - 342
  • [27] Why do UO2 secondary phases and spent nuclear fuel float?
    McNamara, BK
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2003, 225 : U646 - U647
  • [28] PRELIMINARY-STUDY OF SPENT UO2 FUEL CORROSION IN THE PRESENCE OF BENTONITE
    FORSYTH, RS
    WERME, LO
    BRUNO, J
    JOURNAL OF NUCLEAR MATERIALS, 1988, 160 (2-3) : 218 - 223
  • [29] Accelerated dissolution process of the spent fuel (UO2) under repository conditions
    Iglesias, Eduardo
    Quinones, Javier
    Rodriguez, Nieves
    ACTINIDES 2008 - BASIC SCIENCE, APPLICATIONS AND TECHNOLOGY, 2008, 1104 : 101 - 106
  • [30] Effects of α and γ radiolysis of water on alteration of the spent UO2 nuclear fuel matrix
    Jégou, C
    Broudic, V
    Poulesquen, A
    Bart, JM
    SCIENTIFIC BASIS FOR NUCLEAR WASTE MANAGEMENT XXVII, 2004, 807 : 391 - 396