Implementation of an early rule-out pathway for myocardial infarction using a high-sensitivity cardiac troponin T assay

被引:6
|
作者
Sandeman, Dennis [1 ]
Syed, Maaz B. J. [2 ]
Kimenai, Dorien M. [3 ]
Lee, Kuan Ken [3 ]
Anand, Atul [3 ]
Joshi, Shruti S. [3 ]
Dinnel, Lorraine [1 ]
Wenham, Philip R. [4 ]
Campbell, Ken [4 ]
Jarvie, Mary [4 ]
Galloway, Donna [4 ]
Anderson, Mhairi [4 ]
Roy, Bappa [5 ]
Andrews, Jack P. M. [3 ]
Strachan, Fiona E. [3 ]
Ferry, Amy, V [3 ]
Chapman, Andrew R. [3 ]
Elsby, Sarah [6 ]
Francis, Mark [1 ]
Cargill, Robert [1 ]
Shah, Anoop S., V [7 ]
Mills, Nicholas L. [3 ,8 ]
机构
[1] NHS Fife, Cardiol Dept, Kirkcaldy, Scotland
[2] Univ Edinburgh, Div Clin & Surg Sci, Edinburgh, Midlothian, Scotland
[3] Univ Edinburgh, British Heart Fdn, Ctr Cardiovasc Sci, Edinburgh, Midlothian, Scotland
[4] NHS Fife, Biochem Dept, Kirkcaldy, Scotland
[5] NHS Fife, Emergency Dept, Kirkcaldy, Scotland
[6] NHS Fife, Informat Serv, Dunfermline, Fife, Scotland
[7] London Sch Hyg & Trop Med, London, England
[8] Univ Edinburgh, Usher Inst, Edinburgh, Midlothian, Scotland
来源
OPEN HEART | 2021年 / 8卷 / 02期
基金
英国医学研究理事会; 英国工程与自然科学研究理事会; 英国惠康基金; 英国经济与社会研究理事会;
关键词
EARLY-DIAGNOSIS; ALGORITHM;
D O I
10.1136/openhrt-2021-001769
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives Patients with suspected acute coronary syndrome and high-sensitivity cardiac troponin (hs-cTn) concentrations below the limit of detection at presentation are low risk. We aim to determine whether implementing this approach facilitates the safe early discharge of patients. Methods In a prospective single-centre cohort study, consecutive patients with suspected acute coronary syndrome were included before (standard care) and after (intervention) implementation of an early rule-out pathway. During standard care, myocardial infarction was ruled out if hs-cTnT concentrations were <99th centile (14 ng/L) at presentation and at 6-12 hours after symptom onset. In the intervention, patients were ruled out if hs-cTnT concentrations were <5 ng/L at presentation and symptoms present for >= 3 hours or were >= 5 ng/L and unchanged within the reference range at 3 hours. We compared duration of stay (efficacy) and all-cause death at 1 year (safety) before and after implementation. Results We included 10 315 consecutive patients (64 +/- 16 years, 46% women) with 6642 (64%) and 3673 (36%) in the standard care and intervention groups, respectively. Duration of stay was reduced from 534 (IQR, 220-2279) to 390 (IQR, 218-1910) min (p<0.001) after implementation. At 1 year, all-cause death occurred in 10.9% (721 of 6642) and 10.4% (381 of 3673) of patients in the standard care group (referent) and intervention group, respectively (adjusted OR 1.02, 95% CI 0.88 to 1.18). Conclusion In patients with suspected acute coronary syndrome, implementing an early rule-out pathway using hs-cTnT concentrations <5 ng/L at presentation reduced the duration of stay in hospital without compromising safety.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] Validation of presentation and 3 h high-sensitivity troponin to rule-in and rule-out acute myocardial infarction
    Pickering, John W.
    Greenslade, Jaimi H.
    Cullen, Louise
    Flaws, Dylan
    Parsonage, William
    George, Peter
    Worster, Andrew
    Kavsak, Peter A.
    Than, Martin P.
    HEART, 2016, 102 (16) : 1270 - 1278
  • [32] Rapid Rule-Out of Acute Myocardial Injury Using a Single High-Sensitivity Cardiac Troponin I Measurement
    Sandoval, Yader
    Smith, Stephen W.
    Shah, Anoop. S. V.
    Anand, Atul
    Chapman, Andrew R.
    Love, Sara A.
    Schulz, Karen
    Cao, Jing
    Mills, Nicholas L.
    Apple, Fred S.
    CLINICAL CHEMISTRY, 2017, 63 (01) : 369 - 376
  • [33] Single High-Sensitivity Cardiac Troponin I to Rule Out Acute Myocardial Infarction
    Sandoval, Yader
    Smith, Stephen W.
    Love, Sara A.
    Sexter, Anne
    Schulz, Karen
    Apple, Fred S.
    AMERICAN JOURNAL OF MEDICINE, 2017, 130 (09): : 1076 - +
  • [34] Prognostic impact of stepwise 0/1/3h rule-out of myocardial infarction using high-sensitivity troponin T
    Lehmacher, J.
    Guo, L.
    Toprak, B.
    Soerensen, N. A.
    Haller, P. M.
    Schock, A.
    Hartikainen, T. S.
    Westermann, D.
    Zeller, T.
    Blankenberg, S.
    Neumann, J. T.
    Twerenbold, R.
    EUROPEAN HEART JOURNAL, 2023, 44
  • [35] Early Rule-Out Strategies in the Emergency Department Utilizing High-Sensitivity Cardiac Troponin Assays
    Lopez-Ayala, Pedro
    Boeddinghaus, Jasper
    Koechlin, Luca
    Nestelberger, Thomas
    Mueller, Christian
    CLINICAL CHEMISTRY, 2021, 67 (01) : 114 - 123
  • [36] Combined testing of copeptin and high-sensitivity cardiac troponin T at presentation in comparison to other algorithms for rapid rule-out of acute myocardial infarction
    Mueller-Hennessen, Matthias
    Lindahl, Bertil
    Giannitsis, Evangelos
    Vafaie, Mehrshad
    Biener, Moritz
    Haushofer, Alexander C.
    Seier, Josef
    Christ, Michael
    Alquezar-Arbe, Aitor
    DeFilippi, Christopher R.
    McCord, James
    Body, Richard
    Panteghini, Mauro
    Jernberg, Tomas
    Plebani, Mario
    Verschuren, Franck
    French, John K.
    Christenson, Robert H.
    Dinkel, Carina
    Katus, Hugo A.
    Mueller, Christian
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2019, 276 : 261 - 267
  • [37] A single high-sensitivity cardiac troponin T compared to the HEART score for a rapid rule-out of acute myocardial infarction at a prehospital emergency clinic
    Johannessen, T. R.
    Atar, D.
    Vallersnes, O. M.
    Larstorp, A. C. K.
    Mdala, I
    Halvorsen, S.
    EUROPEAN HEART JOURNAL, 2020, 41 : 1680 - 1680
  • [38] Rapid rule out of acute myocardial infarction using undetectable levels of high-sensitivity cardiac troponin
    Gimenez, Maria Rubini
    Hoeller, Rebeca
    Reichlin, Tobias
    Zellweger, Christa
    Twerenbold, Raphael
    Reiter, Miriam
    Moehring, Berit
    Wildi, Karin
    Mosimann, Tamina
    Mueller, Mira
    Meller, Bernadette
    Hochgruber, Thomas
    Ziller, Ronny
    Sou, Seoung Mann
    Murray, Karsten
    Sakarikos, Konstantin
    Ernst, Susanne
    Gea, Joaquim
    Campodarve, Isabel
    Vilaplana, Carles
    Haaf, Philip
    Steuer, Stephan
    Minners, Jan
    Osswald, Stefan
    Mueller, Christian
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2013, 168 (04) : 3896 - 3901
  • [39] Acceptable Analytical Variation May Exceed High-Sensitivity Cardiac Troponin I Cutoffs in Early Rule-Out and Rule-In Acute Myocardial Infarction Algorithms
    Kavsak, Peter A.
    Don-Wauchope, Andrew C.
    Hill, Stephen A.
    Worster, Andrew
    CLINICAL CHEMISTRY, 2016, 62 (06) : 887 - 889
  • [40] Sex-Specific High-Sensitivity Cardiac Troponin Thresholds for Rule-Out of Non-ST-Elevation Myocardial Infarction
    Restan, Ingar Ziad
    Steiro, Ole-Thomas
    Tjora, Hilde L.
    Langoergen, Joerund
    Omland, Torbjorn
    Collinson, Paul O.
    Bjoerneklett, Rune
    Vikenes, Kjell
    Steinsvik, Trude
    Skadberg, Oyvind
    CIRCULATION, 2023, 148