Sampling and analysis of airborne particulate matter and aerosols using in-needle trap and SPME fiber devices

被引:162
|
作者
Koziel, JA
Odziemkowski, M
Pawliszyn, J [1 ]
机构
[1] Univ Waterloo, Dept Chem, Waterloo, ON N2L 3G1, Canada
[2] Univ Waterloo, Dept Earth Sci, Waterloo, ON N2L 3G1, Canada
关键词
D O I
10.1021/ac000835s
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A needle trap device (NTD) and commercial poly(dimethylsiloxane) (PDMS) 7-mum film thickness solid-phase microextraction (SPME) fibers were used for the sampling and analysis of aerosols and airborne particulate matter (PM) from an inhaler-administered drag, spray insect repellant, and tailpipe diesel exhaust. The NTD consisted of a 0.53-mm o.d. stainless steel needle having 5 mm of quartz wool packing section near the needle tip. Samples were collected by drawing air across the NTD with a Luer-tip syringe or via direct exposure of the SPME fiber. The mass loading of PM was varied by adjusting the volume of air pulled through the NTD or by varying the sampling time for the SPME fiber. The air volumes ranged from 0.1 to 50 mt, and sampling times varied from 10 s to 16 min; Particulates were either trapped on the needle packing or sorbed onto the SPME fiber, The devices were introduced to a chromatograph/mass spectrometer (GC/MS) injector for 5 min desorption, In the case of the NTD, 10 muL of clean air was delivered by a gas-tight syringe to aid the introduction of desorbed analytes. The compounds sorbed onto particles extracted by the SPME fiber or trapped in the needle device were desorbed in the injector and no carry-over was observed, Both devices performed well in extracting airborne polycyclic aromatic hydrocarbons: (PAHs) in diesel exhaust, triamcinolone acetonide in a dose of asthma drug and BEET in a dose of insect repellant spray, Results suggest that the NTDs and PDMS 7-mum fibers can be used for airborne particulate sampling and analysis, providing a simple, fast, reusable, and cost-effective screening tool, The advantage of the SPME fiber is the open-bed geometry allowing spectroscopic investigations of particulates; for example, with Raman microspectroscopy.
引用
收藏
页码:47 / 54
页数:8
相关论文
共 50 条
  • [31] Flow Injection Analysis Technique for Online Preconcentration of Lead Ions in Airborne Particulate Matter Using Imprinted Polymer as the Sorbent
    Muhammad Bachri Amran
    Novita Ambarsari
    Muhammad Ali Zulfikar
    Asri Indrawati
    Rusnadi Rusnadi
    Saipul Hamdi
    [J]. Journal of Analysis and Testing, 2024, 8 : 180 - 190
  • [32] Flow Injection Analysis Technique for Online Preconcentration of Lead Ions in Airborne Particulate Matter Using Imprinted Polymer as the Sorbent
    Muhammad Bachri Amran
    Novita Ambarsari
    Muhammad Ali Zulfikar
    Asri Indrawati
    Rusnadi Rusnadi
    Saipul Hamdi
    [J]. Journal of Analysis and Testing, 2024, 8 (02) : 180 - 190
  • [33] Speciation of antimony in airborne particulate matter using ultrasound probe fast extraction and analysis by HPLC-HG-AFS
    Bellido-Martin, A.
    Gomez-Ariza, J. L.
    Smichowsky, P.
    Sanchez-Rodas, D.
    [J]. ANALYTICA CHIMICA ACTA, 2009, 649 (02) : 191 - 195
  • [34] Flow Injection Analysis Technique for Online Preconcentration of Lead Ions in Airborne Particulate Matter Using Imprinted Polymer as the Sorbent
    Amran, Muhammad Bachri
    Ambarsari, Novita
    Zulfikar, Muhammad Ali
    Indrawati, Asri
    Rusnadi, Rusnadi
    Hamdi, Saipul
    [J]. JOURNAL OF ANALYSIS AND TESTING, 2024, 8 (02) : 180 - 190
  • [35] Simultaneous sampling and analysis for vapor mercury in ambient air using needle trap coupled with gas chromatography-mass spectrometry
    Cai, Jibao
    Ouyang, Gangfeng
    Gong, Ying
    Pawliszyn, Janusz
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2008, 1213 (01) : 19 - 24
  • [36] Direct Analysis of Low-Volatile Molecular Marker Extract from Airborne Particulate Matter Using Sensitivity Correction Method
    Irei, Satoshi
    [J]. INTERNATIONAL JOURNAL OF ANALYTICAL CHEMISTRY, 2016, 2016
  • [37] Environmental analysis of polar and non-polar Polycyclic Aromatic Compounds in airborne particulate matter, settled dust and soot: Part I: Sampling and sample preparation
    Galmiche, Mathieu
    Delhomme, Olivier
    Francois, Yannis-Nicolas
    Millet, Maurice
    [J]. TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2021, 134
  • [38] Analysis of Odor-Causing VOCs and Semi-VOCs Associated with Particulate Matter in Swine Barns Using SPME-GC-MS-Olfactometry
    Cai, Lingshuang
    Koziel, Jacek A.
    Lo, Yin-Cheung
    Hoff, Steven J.
    [J]. OLFACTION AND ELECTRONIC NOSE, PROCEEDINGS, 2009, 1137 : 411 - 412
  • [39] Assessment of occupational exposure and contamination by means of airborne particulate matter and biomonitors using k0 instrumental neutron activation analysis
    Menezes, MABC
    Maia, ECP
    Filho, SS
    Albinati, C
    [J]. JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2002, 254 (03) : 499 - 507
  • [40] Determination of antimony in airborne particulate matter collected on filters using direct solid sampling and high-resolution continuum source graphite furnace atomic absorption spectrometry
    Araujo, Rennan G. O.
    Welz, Bernhard
    Castilho, Ivan N. B.
    Vale, Maria Goreti R.
    Smichowski, Patricia
    Ferreira, Sergio L. C.
    Becker-Ross, Helmut
    [J]. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2010, 25 (04) : 580 - 584