Shaking table tests on the multi-dimensional seismic response of long-span grid structure with base-isolation

被引:20
|
作者
Xu, Weizhi [1 ]
Du, Dongsheng [1 ]
Wang, Shuguang [1 ]
Liu, Weiqing [1 ]
Li, Weiwei [1 ]
机构
[1] Nanjing Tech Univ, Coll Civil Engn, Nanjing 211816, Jiangsu, Peoples R China
基金
国家重点研发计划; 中国国家自然科学基金;
关键词
Shaking table test; Long-span; Base isolation; Dynamic characteristics; Multi-dimensional seismic response; ISOLATION DEVICE;
D O I
10.1016/j.engstruct.2019.109802
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Seismic isolation technology is being applied in large long-span-structured public buildings more and more often worldwide. Aimed to investigate the horizontal and vertical dynamic response of long-span gird structure, the shaking table tests of 1/20 scale long-span grid structures with and without base-isolation considering horizontal two-dimensional (2D) and three-dimensional (3D) seismic excitations were conducted. The test model was designed as ordinary long-span spatial grid structure, but with lead rubber bearings. Data on the acceleration, displacement, strain, and shear force of the base-isolation model and fixed-base model were collected and compared. The dynamic responses of the structure subjected to the horizontal and vertical ground motions with different intensities were studied. The experimental results showed that compared with the fixed-base model, the horizontal period and damping ratio of the base-isolation model can be significantly improved, reducing the horizontal dynamic response of the superstructure, and the horizontal isolation effect was improved with the increase of the seismic excitation intensity. The horizontal acceleration of the roof layer for the base-isolation model was amplified in 3D excitation compared to horizontal input due to horizontal-vertical coupling. Meanwhile, significant vertical acceleration and displacement responses of long-span roof for fixed-base structure were induced by horizontal seismic excitation. Although base isolation could not provide protection against vertical excitation, vertical isolation effect under 3D input could be achieved by effectively suppressing the vertical dynamic response of grid roof induced by the horizontal seismic component.
引用
收藏
页数:16
相关论文
共 50 条
  • [41] Seismic Protection of the Goddess of Morgantina Statue Through an Innovative Base-Isolation Device: Validation by Shake-Table Tests
    Alberti, Elena
    Ausenda, Giovanni
    Castino, Maria Chiara
    Lo Iacono, Francesco
    Navarra, Giacomo
    SEISMIC ISOLATION, ENERGY DISSIPATION AND ACTIVE VIBRATION CONTROL OF STRUCTURES, 17WCSI 2022, 2023, 309 : 717 - 725
  • [42] Shaking Table Tests Examining Seismic Response of Suspended Ceilings Attached to Large-Span Spatial Structures
    Lu, Yan
    Mosqueda, Gilberto
    Han, Qinghua
    Zhao, Yifeng
    JOURNAL OF STRUCTURAL ENGINEERING, 2018, 144 (09)
  • [43] Non-stationary random seismic analysis of long-span spatial structures under multi-dimensional and multi-support earthquake excitations
    Ding, Yang
    Lin, Wei
    Li, Zhong-Xian
    Advances in Structural Engineering:Theory and Applications Vols 1 and 2, 2006, : 167 - 173
  • [44] Vertical pseudo-dynamic experimental study on long-span reticulated structures with multi-dimensional earthquake isolation and mitigation devices
    Xu, Zhao-Dong
    Wang, Xu-Dong
    Wang, Shao-An
    JOURNAL OF VIBRATION AND CONTROL, 2014, 20 (15) : 2326 - 2337
  • [45] Vertical seismic response analysis of long-span composite open-web grid floor
    Yang, Qizhu
    Ma, Kejian
    Zhang, Huagang
    Wei, Yanhui
    Xiang, Ze
    INTERNATIONAL JOURNAL OF STRUCTURAL INTEGRITY, 2021, 12 (02) : 340 - 355
  • [46] Non-stationary random seismic analysis of long-span spatial structures under multi-support and multi-dimensional earthquake excitations
    School of Civil Engineering, Tianjin University, Tianjin 300072, China
    Gongcheng Lixue, 2007, 3 (97-103):
  • [47] Horizontal pseudo-dynamic experimental study on long-span reticulated structures with multi-dimensional earthquake isolation and mitigation devices
    Xu, Zhao-Dong
    Shi, Chun-Fang
    Guo, Yi-Feng
    JOURNAL OF VIBRATION AND CONTROL, 2015, 21 (06) : 1086 - 1099
  • [48] Shaking table test for the structure with three-dimensional base isolation and overturn resistance devices
    Yan, Xue-Yuan
    Zhang, Yong-Shan
    Wang, Huan-Ding
    Wei, Lu-Shun
    Gongcheng Lixue/Engineering Mechanics, 2010, 27 (05): : 91 - 96
  • [49] Rocking dynamic model of three-dimensional isolation structure and validation of shaking table tests
    Liu W.-G.
    Li J.-L.
    Xu H.
    He W.-F.
    Zhendong Gongcheng Xuebao/Journal of Vibration Engineering, 2022, 35 (05): : 1200 - 1210
  • [50] Dynamic analysis of three-directional vibration isolation and mitigation for long-span grid structure
    Xu, Zhao-Dong
    Zhang, Tian
    Huang, Xing-Huai
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2023, 202