Clinical analysis of CAD-CAM milled and printed complete dentures using computerized occlusal force analyser

被引:23
|
作者
Chaturvedi, Saurabh [1 ]
Addas, Mohamed Khaled [1 ]
Alqahtani, Nasser M. [1 ]
Al Ahmari, Nasser M. [1 ]
Alfarsi, Mohammed A. [1 ]
机构
[1] King Khalid Univ, Coll Dent, Dept Prosthet Dent, Abha, Saudi Arabia
关键词
Digital dentures; T-Scan; occlusal forces; subtractive technique; additive technique milling; CAD-CAM; LINGUALIZED OCCLUSION; PROSTHESIS; MOVEMENT; TEETH;
D O I
10.3233/THC-202766
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
BACKGROUND: Digital complete dentures (CDs) by computer-aided designing and computer-aided manufacturing (CAD-CAM) techniques (milling and three-dimensional (3-D) printing) have been evaluated clinically and provided satisfactory results. But clinical studies assessing occlusal forces by digital dentures are lacking. OBJECTIVES: To compare the occlusal force parameters in complete dentures (CDs) fabricated by milling, 3-D printing and conventional techniques having 3 commonly used occlusal schemes, using computerized occlusal force analysis system (Tech-Scan III- T-Scan III). METHODS: A total of 45 CDs were fabricated for 5 patients. Nine sets of CDs were made for each patient and were divided into 3 groups: Conventional CDs (CCD), Milled CDs (MCD), and 3-D printed CDs (3-DP CD). The CDs in each group were further divided into 3 sub-groups based on occlusion schemes - bilateral balanced (BBO), lingualized (LO) and mono plane (MP). Occlusal force analysis [percentage (%) of occlusal force applied on the right and left sides of the arch difference between them, centralization of forces and % of maximum occlusal/bite force] was done using computerized occlusal analysis system (T-Scan III) at the time of denture insertion. Univariate regression analysis and logistic regression analysis were performed (p < 0.05). RESULTS: The intergroup comparison of force distribution on right and left side in CDs fabricated by various techniques showed insignificant differences (p > 0.05) but statistically significant differences (p < 0.01) were found in right-left side force difference, maximum bite force % and centralization of forces. The maximum force difference on right and left side was observed CCD with MO (37.48 +/- 1.03 N) and maximum occlusal-bite force % was observed for 3-DPCD with LO (95.40 +/- 1.30 N). In comparison to 3-DP CD, the chances of centre of force out of ellipse (centralization of forces) was 3.36 and 2.15 times more in CCD and MCD techniques made CDs respectively. CONCLUSIONS: The occlusal parameters in CDs were affected by the fabrication techniques and occlusal schemes of CDs. The digital CDs retain adjusted occlusal schemes better and 3-DP CDs with BBO and LO occlusal schemes provided centralization of forces, better distribution and high maximum occlusal force % respectively.
引用
收藏
页码:797 / 811
页数:15
相关论文
共 50 条
  • [31] A method to improve positioning of denture teeth on denture bases for CAD-CAM complete dentures: A dental technique
    Feng, Yue
    Ma, Sai
    Zhong, Sheng
    Niu, Lina
    Feng, Zhihong
    JOURNAL OF PROSTHETIC DENTISTRY, 2024, 132 (01): : 46 - 50
  • [32] Effect of Duplication Techniques on the Fitting Accuracy of CAD-CAM Milled, 3D-Printed, and Injection-Molded Mandibular Complete Denture Bases
    Emam, Abdel-Naser M.
    El-Esawy, Ahmed Ayman
    Alyami, Mohammed Hamad
    Baraka, Yasser
    Gad, Mohammed M.
    Helal, Mohamed Ahmed
    DENTISTRY JOURNAL, 2024, 12 (02)
  • [33] Immediately loaded CAD-CAM manufactured fixed complete dentures using flapless implant placement procedures: A cohort study of consecutive patients
    Sanna, Anna M.
    Molly, Liene
    van Steenberghe, Daniel
    JOURNAL OF PROSTHETIC DENTISTRY, 2007, 97 (06): : 331 - 339
  • [34] Letter to the Editor regarding "A method of fabricating a stackable CAD-CAM custom record tray for complete dentures" by Liao and Budsabong
    Zhang, Huicong
    Wang, Wang
    JOURNAL OF PROSTHETIC DENTISTRY, 2024, 132 (05): : 1090 - 1092
  • [35] Comparison of retentive force and wear pattern of Locator® and ADD-TOC attachments combined with CAD-CAM milled bar
    Chae, Sung-Ki
    Cho, Won-Tak
    Choi, Jae-Won
    Bae, Eun-Bin
    Bae, Ji-Hyeon
    Bae, Gang-Ho
    Huh, Jung-Bo
    JOURNAL OF ADVANCED PROSTHODONTICS, 2022, 14 (01): : 12 - 21
  • [36] In vitro analysis of the fracture resistance of CAD-CAM monolithic zirconia molar crowns with different occlusal thickness
    Sorrentino, Roberto
    Triulzio, Clementina
    Tricarico, Maria Gabriella
    Bonadeo, Giovanni
    Gherlone, Enrico Felice
    Ferrari, Marco
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2016, 61 : 328 - 333
  • [37] CAD/CAM FABRICATED COMPLETE DENTURES: CONCEPTS AND CLINICAL METHODS OF OBTAINING REQUIRED MORPHOLOGICAL DATA
    Goodacre, Charles J.
    Garbacea, Antoanela
    Naylor, W. Patrick
    Daher, Tony
    Marchack, Christopher B.
    Lowry, Jean
    JOURNAL OF PROSTHETIC DENTISTRY, 2012, 107 (01): : 34 - 46
  • [38] Clinical performance of CAD-CAM-fabricated complete dentures: A cross-sectional study
    Saponaro, Paola C.
    Yilmaz, Burak
    Heshmati, Reza H.
    McGlumphy, Edwin A.
    JOURNAL OF PROSTHETIC DENTISTRY, 2016, 116 (03): : 431 - 435
  • [39] Physical, Mechanical, and Anti-Biofilm Formation Properties of CAD-CAM Milled or 3D Printed Denture Base Resins: In Vitro Analysis
    Carvalho Porto de Freitas, Rodrigo Falcao
    Duarte, Simone
    Feitosa, Sabrina
    Dutra, Vinicius
    Lin, Wei-Shao
    Dias Panariello, Beatriz Helena
    Porto Carreiro, Adriana da Fonte
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2023, 32 : 38 - 44
  • [40] Occlusal Pressure Analysis of Complete Dentures after Microwave Disinfection: A Clinical Study
    Manzolli Basso, Michael Frederico
    Giampaolo, Eunice Teresinha
    Vergani, Carlos Eduardo
    Pavarina, Ana Claudia
    Machado, Ana Lucia
    Jorge, Janaina Habib
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2017, 26 (07): : 606 - 610