Clinical Inferences of Cardiovascular Implantable Electronic Device Analysis at Autopsy

被引:22
|
作者
Sinha, Sunil K. [1 ]
Crain, Barbara [2 ]
Flickinger, Katie [2 ]
Calkins, Hugh [1 ]
Rickard, John [3 ]
Cheng, Alan [1 ,4 ]
Berger, Ronald [1 ]
Tomaselli, Gordon [1 ]
Marine, Joseph E. [1 ]
机构
[1] Johns Hopkins Univ, Sch Med, Div Cardiol, Baltimore, MD USA
[2] Johns Hopkins Univ, Sch Med, Dept Pathol, Baltimore, MD 21205 USA
[3] Cleveland Clin, Dept Cardiovasc Med, Cleveland, OH 44106 USA
[4] Medtronic, Dublin, Ireland
关键词
defibrillator; nonsudden death; pacemaker; post-mortem; sudden death; SUDDEN CARDIAC DEATH; HEART-FAILURE; PACEMAKERS; DEFIBRILLATORS; GUIDELINES;
D O I
10.1016/j.jacc.2016.06.052
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND Cardiovascular implantable electronic device (CIED) removal and interrogation are recommended at autopsy in suspected cases of sudden cardiac death, but data on the role of nonselective post-mortem CIED (pacemaker or defibrillator) analysis in this setting are lacking. OBJECTIVES This study undertook an institutional registry analysis to determine the utility of systematic routine CIED removal, interrogation, and analysis at autopsy. METHODS From May 19, 2009, to May 18, 2015, autopsy subjects with a CIED at a Johns Hopkins University medical institution (Baltimore, Maryland) underwent CIED removal and interrogation by an electrophysiologist for clinical alerts. The CIED was then submitted for technical analysis by the manufacturer. The CIED interrogation, the manufacturer's technical analysis, and the final autopsy report were all cataloged in the Johns Hopkins Post-mortem CIED Registry. RESULTS A total of 2,025 autopsies were performed; 84 subjects had CIEDs removed and analyzed. These devices included 37 pacemakers and 47 defibrillators. Overall, 43 subjects had died suddenly, and 41 had not died suddenly. Significant clinical alerts (sustained tachyarrhythmias or an elevated fluid index value) were seen in 62.8% cases of sudden deaths. In the nonsudden death cohort, 19.5% displayed a significant clinical alert. Significant association of CIED alerts were noted when comparing sudden deaths versus nonsudden deaths (p < 0.001), defibrillators versus pacemakers (p < 0.005), and cardiac versus noncardiac causes of death (p < 0.001). Manufacturer analyses revealed a case of premature pacemaker battery depletion, as well as a hard reset in a defibrillator as a result of cold exposure. CONCLUSIONS Post-mortem CIED analysis was clinically useful in assisting with determination of the timing, mechanism, and cause of death in the majority of sudden deaths and in almost 20% of nonsudden deaths. The authors advocate CIED removal with analysis as an important diagnostic tool in all autopsies and to assist manufacturers in identifying potentially fatal device failures. (C) 2016 by the American College of Cardiology Foundation.
引用
收藏
页码:1255 / 1264
页数:10
相关论文
共 50 条
  • [11] Cardiovascular Implantable Electronic Device Infections A Contemporary Review
    Bielick, Catherine G.
    Arnold, Christopher J.
    Chu, Vivian H.
    INFECTIOUS DISEASE CLINICS OF NORTH AMERICA, 2024, 38 (04) : 673 - 691
  • [12] DAPTOMYCIN IN CARDIOVASCULAR IMPLANTABLE ELECTRONIC DEVICE (CIED) ENDOCARDITIS
    Tekce, A. Y. Tezer
    Erbay, A.
    Sen, S.
    Gul, M.
    Erbay, A. R.
    INTERNATIONAL JOURNAL OF ANTIMICROBIAL AGENTS, 2013, 41 : S28 - S28
  • [13] Microbiology and Pathogenesis of Cardiovascular Implantable Electronic Device Infections
    Nagpal, Avish
    Baddour, Larry M.
    Sohail, Muhammad R.
    CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2012, 5 (02): : 433 - 441
  • [14] Cardiovascular Implantable Electronic Device Service as an Anesthesia Service
    Berris, Joshua R.
    ANESTHESIOLOGY, 2016, 124 (05) : 1194 - 1195
  • [15] Contemporary management of cardiovascular implantable electronic device infections
    Sohail, Muhammad R.
    Sultan, Omer W.
    Raza, Sania S.
    EXPERT REVIEW OF ANTI-INFECTIVE THERAPY, 2010, 8 (07) : 831 - 839
  • [16] Clinical Features and Outcomes of Cardiovascular Implantable Electronic Device Infections Due to Staphylococcal Species
    Le, Katherine Y.
    Sohail, Muhammad R.
    Friedman, Paul A.
    Uslan, Daniel Z.
    Cha, Stephen S.
    Hayes, David L.
    Wilson, Walter R.
    Steckelberg, James M.
    Baddour, Larry M.
    AMERICAN JOURNAL OF CARDIOLOGY, 2012, 110 (08): : 1143 - 1149
  • [17] Impact of prior aspirin therapy on clinical manifestations of cardiovascular implantable electronic device infections
    Habib, Ammar
    Irfan, Muna
    Baddour, Larry M.
    Le, Katherine Y.
    Anavekar, Nandan S.
    Lohse, Christine M.
    Friedman, Paul A.
    Hayes, David L.
    Wilson, Walter R.
    Steckelberg, James M.
    Sohail, M. Rizwan
    EUROPACE, 2013, 15 (02): : 227 - 235
  • [18] Anesthetic Choice for Cardiovascular Implantable Electronic Device Placement and Lead Removal: A National Anesthesia Clinical Outcomes Registry Analysis
    Mcguire, Joseph A.
    Hayanga, J. W. Awori
    Thibault, Dylan
    Zukowski, Anna
    Grose, Brian
    Woods, Kaitlin
    Schwartzman, David
    Hayanga, Heather K.
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2023, 37 (12) : 2461 - 2469
  • [19] Method for preclinical pathology evaluation and analysis of cardiovascular implantable electronic device implant sites
    Jessen, Staci L.
    O'Brien, Maureen T.
    Lancon, Trevor W.
    Smith, Harrison R.
    Suarez, Leslie L.
    Wilcox, Matthew D.
    Miller, Matthew
    Weeks, Brad R.
    Clubb, Fred J., Jr.
    CARDIOVASCULAR PATHOLOGY, 2018, 36 : 44 - 52
  • [20] Clinical Significance of Collateral Superficial Vein Across Clavicle in Patients With Cardiovascular Implantable Electronic Device
    Hosoda, Junya
    Ishikawa, Toshiyuki
    Matsushita, Kohei
    Matsumoto, Katsumi
    Sugano, Teruyasu
    Ishigami, Tomoaki
    Kimura, Kazuo
    Umemura, Satoshi
    CIRCULATION JOURNAL, 2014, 78 (08) : 1846 - 1850