Inter-rater reliability, intra-rater reliability and internal consistency of the Brisbane Evidence-Based Language Test

被引:5
|
作者
Rohde, Alexia [1 ,2 ]
McCracken, Molly [2 ]
Worrall, Linda [2 ]
Farrell, Anna [3 ]
O'Halloran, Robyn [4 ]
Godecke, Erin [5 ]
David, Michael [6 ]
Doi, Suhail A. [7 ]
机构
[1] Southern Cross Univ, Speech Pathol Dept, Bilinga, Qld 4225, Australia
[2] Univ Queensland, Speech Pathol Dept, Brisbane, Qld, Australia
[3] Royal Brisbane & Womens Hosp, Dept Speech Pathol, Brisbane, Qld, Australia
[4] La Trobe Univ, Dept Community & Clin Allied Hlth, Melbourne, Vic, Australia
[5] Edith Cowan Univ, Dept Speech Pathol, Joondalup, Australia
[6] Univ Queensland, Sch Publ Hlth, Brisbane, Qld, Australia
[7] Qatar Univ, Dept Populat Med, Doha, Qatar
关键词
Aphasia; test; stroke; reliability; psychometric properties; outcome measures; AGREEMENT;
D O I
10.1080/09638288.2020.1776774
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Purpose:To examine the inter-rater reliability, intra-rater reliability, internal consistency and practice effects associated with a new test, the Brisbane Evidence-Based Language Test. Methods:Reliability estimates were obtained in a repeated-measures design through analysis of clinician video ratings of stroke participants completing the Brisbane Evidence-Based Language Test. Inter-rater reliability was determined by comparing 15 independent clinicians' scores of 15 randomly selected videos. Intra-rater reliability was determined by comparing two clinicians' scores of 35 videos when re-scored after a two-week interval. Results:Intraclass correlation coefficient (ICC) analysis demonstrated almost perfect inter-rater reliability (0.995; 95% confidence interval: 0.990-0.998), intra-rater reliability (0.994; 95% confidence interval: 0.989-0.997) and internal consistency (Cronbach's alpha = 0.940 (95% confidence interval: 0.920-1.0)). Almost perfect correlations (0.998; 95% confidence interval: 0.995-0.999) between face-to-face and video ratings were obtained. Conclusion:The Brisbane Evidence-Based Language Test demonstrates almost perfect inter-rater reliability, intra-rater reliability and internal consistency. High correlation coefficients and narrow confidence intervals demonstrated minimal practice effects with scoring or influence of years of clinical experience on test scores. Almost perfect correlations between face-to-face and video scoring methods indicate these reliability estimates have direct application to everyday practice. The test is available from brisbanetest.org.
引用
收藏
页码:637 / 645
页数:9
相关论文
共 50 条
  • [31] Intra-rater and inter-rater reliability of pressure pain threshold assessment in stroke patients
    Zhang, Yong-Hui
    Wang, Yu-Chen
    Hu, Gong-Wei
    Ding, Xiao-Qin
    Shen, Xiao-Hua
    Ng, Hui Ya
    Rong, Ji-Feng
    Wang, Xue-Qiang
    [J]. EUROPEAN JOURNAL OF PHYSICAL AND REHABILITATION MEDICINE, 2022, 58 (04) : 549 - 557
  • [32] Intra-rater and inter-rater reliability of the rapid entire body assessment (REBA) tool
    Schwartz, Adam H.
    Albin, Thomas J.
    Gerberich, Susan G.
    [J]. INTERNATIONAL JOURNAL OF INDUSTRIAL ERGONOMICS, 2019, 71 : 111 - 116
  • [33] An evaluation of the inter-rater and intra-rater reliability of OccuPro's functional capacity evalution
    Scheel, Carrie
    Mecham, Jim
    Zuccarello, Vic
    Mattes, Ryan
    [J]. WORK-A JOURNAL OF PREVENTION ASSESSMENT & REHABILITATION, 2018, 60 (03): : 465 - 473
  • [34] Intra-rater and inter-rater reliability of the standardized ultrasound protocol for assessing subacromial structures
    Hougs Kjaer, Birgitte
    Ellegaard, Karen
    Wieland, Ina
    Warming, Susan
    Juul-Kristensen, Birgit
    [J]. PHYSIOTHERAPY THEORY AND PRACTICE, 2017, 33 (05) : 398 - 409
  • [35] Intra-rater and Inter-rater consistency of drug induced sleep endoscopy
    Kilavuz, Ahmet Erdem
    Bayram, Ali Alper
    [J]. ENT UPDATES, 2019, 9 (02): : 138 - 143
  • [36] INTER-RATER, INTRA-RATER, AND INTER-MACHINE RELIABILITY OF QUANTITATIVE ULTRASOUND MEASUREMENTS OF THE PATELLAR TENDON
    Gellhorn, Alfred C.
    Carlson, M. Jake
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2013, 39 (05): : 791 - 796
  • [37] Inter-rater, intra-rater and inter-instrument reliability of an electrogoniometer to measure wrist range of motion
    da Silva Camassuti, Patricia Aparecida
    Marcolino, Alexandre Marcio
    Tamanini, Guilherme
    Barbosa, Rafael Inacio
    Barbosa, Amanda Matias
    Registro Fonseca, Marisa de Cassia
    [J]. HAND THERAPY, 2015, 20 (01) : 3 - 10
  • [38] Inter-rater and intra-rater reliability of an adapted Wolf motor function test for older patients with shoulder injuries
    Oberle, Corinna
    Becker, Clemens
    Schoelch, Sabine
    Lenz, Joerg-Uwe
    Studier-Fischer, Stefan
    Augat, Peter
    Schwickert, Lars
    [J]. ZEITSCHRIFT FUR GERONTOLOGIE UND GERIATRIE, 2018, 51 (03): : 293 - 300
  • [39] Assessment of the Human Factors Analysis and Classification System (HFACS): Intra-rater and inter-rater reliability
    Ergai, Awatef
    Cohen, Tara
    Sharp, Julia
    Wiegmann, Doug
    Gramopadhye, Anand
    Shappell, Scott
    [J]. SAFETY SCIENCE, 2016, 82 : 393 - 398
  • [40] Use of superpixels for improvement of inter-rater and intra-rater reliability during annotation of medical images
    Gut, Daniel
    Trombini, Marco
    Kucybala, Iwona
    Krupa, Kamil
    Rozynek, Milosz
    Dellepiane, Silvana
    Tabor, Zbislaw
    Wojciechowski, Wadim
    [J]. MEDICAL IMAGE ANALYSIS, 2024, 94