Inter-rater reliability, intra-rater reliability and internal consistency of the Brisbane Evidence-Based Language Test

被引:5
|
作者
Rohde, Alexia [1 ,2 ]
McCracken, Molly [2 ]
Worrall, Linda [2 ]
Farrell, Anna [3 ]
O'Halloran, Robyn [4 ]
Godecke, Erin [5 ]
David, Michael [6 ]
Doi, Suhail A. [7 ]
机构
[1] Southern Cross Univ, Speech Pathol Dept, Bilinga, Qld 4225, Australia
[2] Univ Queensland, Speech Pathol Dept, Brisbane, Qld, Australia
[3] Royal Brisbane & Womens Hosp, Dept Speech Pathol, Brisbane, Qld, Australia
[4] La Trobe Univ, Dept Community & Clin Allied Hlth, Melbourne, Vic, Australia
[5] Edith Cowan Univ, Dept Speech Pathol, Joondalup, Australia
[6] Univ Queensland, Sch Publ Hlth, Brisbane, Qld, Australia
[7] Qatar Univ, Dept Populat Med, Doha, Qatar
关键词
Aphasia; test; stroke; reliability; psychometric properties; outcome measures; AGREEMENT;
D O I
10.1080/09638288.2020.1776774
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Purpose:To examine the inter-rater reliability, intra-rater reliability, internal consistency and practice effects associated with a new test, the Brisbane Evidence-Based Language Test. Methods:Reliability estimates were obtained in a repeated-measures design through analysis of clinician video ratings of stroke participants completing the Brisbane Evidence-Based Language Test. Inter-rater reliability was determined by comparing 15 independent clinicians' scores of 15 randomly selected videos. Intra-rater reliability was determined by comparing two clinicians' scores of 35 videos when re-scored after a two-week interval. Results:Intraclass correlation coefficient (ICC) analysis demonstrated almost perfect inter-rater reliability (0.995; 95% confidence interval: 0.990-0.998), intra-rater reliability (0.994; 95% confidence interval: 0.989-0.997) and internal consistency (Cronbach's alpha = 0.940 (95% confidence interval: 0.920-1.0)). Almost perfect correlations (0.998; 95% confidence interval: 0.995-0.999) between face-to-face and video ratings were obtained. Conclusion:The Brisbane Evidence-Based Language Test demonstrates almost perfect inter-rater reliability, intra-rater reliability and internal consistency. High correlation coefficients and narrow confidence intervals demonstrated minimal practice effects with scoring or influence of years of clinical experience on test scores. Almost perfect correlations between face-to-face and video scoring methods indicate these reliability estimates have direct application to everyday practice. The test is available from brisbanetest.org.
引用
收藏
页码:637 / 645
页数:9
相关论文
共 50 条
  • [1] Inter-rater and intra-rater reliability of the extended TUG test in elderly participants
    Bedoya-Belmonte, Juan Jose
    Rodriguez-Gonzalez, Maria del Mar
    Gonzalez-Sanchez, Manuel
    Pitarch, Jose Miguel Barreda
    Galan-Mercant, Alejandro
    Cuesta-Vargas, Antonio I.
    [J]. BMC GERIATRICS, 2020, 20 (01)
  • [2] Measuring Essay Assessment: Intra-rater and Inter-rater Reliability
    Kayapinar, Ulas
    [J]. EURASIAN JOURNAL OF EDUCATIONAL RESEARCH, 2014, (57): : 113 - 135
  • [3] Intra-rater and inter-rater reliability of robotic arthrometer DYNEELAX®
    Mihalinec, Katja
    Martinez-Cepa, Carmen B.
    Zuil-Escobar, Juan C.
    Kejzar, Natasa
    Vauhnik, Renata
    [J]. JOURNAL OF EXPERIMENTAL ORTHOPAEDICS, 2024, 11 (03)
  • [4] Optoelectronic plethysmography: Intra-rater and inter-rater reliability in healthy subjects
    Vieira, Danielle S. R.
    Hoffman, Mariana
    Pereira, Danielle A. G.
    Britto, Raquel R.
    Parreira, Veronica F.
    [J]. RESPIRATORY PHYSIOLOGY & NEUROBIOLOGY, 2013, 189 (03) : 473 - 476
  • [5] INTER-RATER AND INTRA-RATER RELIABILITY OF UROFLOWMETRY INTERPRETATION IN ADULT WOMEN
    Rickey, Leslie M.
    Mueller, Elizabeth R.
    Newman, Diane K.
    Markland, Alayne D.
    Falke, Chloe
    Rudser, Kyle
    Lukacz, Emily S.
    [J]. JOURNAL OF UROLOGY, 2023, 209 : E519 - E519
  • [6] Inter-rater and intra-rater reliability of the airway diameter measured by sonography
    Gómez-Tamayo J.C.
    Puerta-Guarín J.I.
    Rojas-Camejo C.M.
    Caicedo J.P.
    Calvache J.A.
    [J]. Journal of Ultrasound, 2018, 21 (1) : 35 - 40
  • [7] INTER-RATER AND INTRA-RATER RELIABILITY OF BRIEF PSYCHIATRIC RATING SCALE
    FLEMENBAUM, A
    ZIMMERMANN, RL
    [J]. PSYCHOLOGICAL REPORTS, 1973, 32 (03) : 783 - 792
  • [8] Inter-Rater Reliability and Intra-Rater Reliability of Assessing the 2-Minute Push-Up Test
    Fielitz, Lynn
    Coelho, Jeffrey
    Horne, Thomas
    Brechue, William
    [J]. MILITARY MEDICINE, 2016, 181 (02) : 167 - 172
  • [9] Intra-rater and inter-rater reliability of 3D facial measurements
    Hobbs-Murphy, Kayna
    Olmedo-Nockideneh, Isabel
    Brazile, William J.
    Morris, Kristen
    Rosecrance, John
    [J]. APPLIED ERGONOMICS, 2024, 116
  • [10] Inter-rater and Intra-rater Reliability of the Videofluoroscopic Dysphagia Scale with the Standardized Protocol
    Min, Ingi
    Woo, Hyeonseong
    Kim, Jae Yoon
    Kim, Tae-Lim
    Lee, Yookyung
    Chang, Won Kee
    Jung, Se Hee
    Lee, Woo Hyung
    Oh, Byung-Mo
    Han, Tai Ryoon
    Seo, Han Gil
    [J]. DYSPHAGIA, 2024, 39 (01) : 43 - 51