Usefulness of two-point Dixon fat-water separation technique in gadoxetic acid-enhanced liver magnetic resonance imaging

被引:11
|
作者
Ding, Ying [1 ]
Rao, Sheng-Xiang [1 ]
Chen, Cai-Zhong [1 ]
Li, Ren-Chen [1 ]
Zeng, Meng-Su [1 ]
机构
[1] Fudan Univ, Zhongshan Hosp, Shanghai Inst Med Imaging, Dept Radiol, Shanghai 200032, Peoples R China
基金
中国国家自然科学基金;
关键词
Dixon-volumetric interpolated breath-hold examination; Fat saturation-volumetric interpolated breath-hold examination; Gadoxetic acid; Volumetric interpolated breath-hold examination; Magnetic resonance imaging; GD-EOB-DTPA; TIME INVERSION-RECOVERY; SUPPRESSION; CONTRAST; PHASE; PULSE; LESIONS; SYSTEM; MRI;
D O I
10.3748/wjg.v21.i16.5017
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
AIM: To compare differences between volumetric interpolated breath-hold examination (VIBE) using two-point Dixon fat-water separation (Dixon-VIBE) and chemically selective fat saturation (FS-VIBE) with magnetic resonance imaging examination. METHODS: Forty-nine patients were included, who were scanned with two VIBE sequences (Dixon-VIBE and FS-VIBE) in hepatobiliary phase after gadoxetic acid administration. Subjective evaluations including sharpness of tumor, sharpness of vessels, strength and homogeneity of fat suppression, and artifacts that were scored using a 4-point scale. The liver-to-lesion contrast was also calculated and compared. RESULTS: Dixon-VIBE with water reconstruction had significantly higher subjective scores than FS-VIBE in strength and homogeneity of fat suppression (< 0.0001) but lower scores in sharpness of tumor (P < 0.0001), sharpness of vessels (P = 0.0001), and artifacts (P = 0.034). The liver-to-lesion contrast on Dixon-VIBE images was significantly lower than that on FS-VIBE (16.6% +/- 9.4% vs 23.9% +/- 12.1%, P = 0.0001). CONCLUSION: Dixon-VIBE provides stronger and more homogenous fat suppression than FS-VIBE, while has lower clarity of focal liver lesions in hepatobiliary phase after gadoxetic acid administration.
引用
收藏
页码:5017 / 5022
页数:6
相关论文
共 50 条
  • [21] Role of gadoxetic acid-enhanced liver magnetic resonance imaging in the evaluation of hepatocellular carcinoma after locoregional treatment
    Marco Gatti
    Cesare Maino
    Fatemeh Darvizeh
    Alessandro Serafini
    Eleonora Tricarico
    Alessia Guarneri
    Riccardo Inchingolo
    Davide Ippolito
    Umberto Ricardi
    Paolo Fonio
    Riccardo Faletti
    World Journal of Gastroenterology, 2022, 28 (26) : 3116 - 3131
  • [22] Prediction of postoperative liver failure using gadoxetic acid-enhanced magnetic resonance imaging in patients with hepatocellular carcinoma
    Jin, Young-Joo
    Lee, Seung Ho
    Cho, Soon Gu
    Kim, Jun Ho
    Lee, Jin-Woo
    Lee, Kun Young
    Shin, Woo Young
    JOURNAL OF GASTROENTEROLOGY AND HEPATOLOGY, 2016, 31 (07) : 1349 - 1356
  • [23] Liver-specific gadoxetic acid-enhanced magnetic resonance for focal lesion evaluation
    Cossio-Torrico, P. E.
    Ramirez-Carmona, C. R.
    Stoopen-Rometti, M.
    Perochena-Gonzalez, A.
    Sosa-Lozano, L. A.
    Kimura-Hayama, E.
    REVISTA DE GASTROENTEROLOGIA DE MEXICO, 2015, 80 (04): : 267 - 275
  • [24] Role of gadoxetic acid-enhanced liver magnetic resonance imaging in the evaluation of hepatocellular carcinoma after locoregional treatment
    Gatti, Marco
    Maino, Cesare
    Darvizeh, Fatemeh
    Serafini, Alessandro
    Tricarico, Eleonora
    Guarneri, Alessia
    Inchingolo, Riccardo
    Ippolito, Davide
    Ricardi, Umberto
    Fonio, Paolo
    Faletti, Riccardo
    WORLD JOURNAL OF GASTROENTEROLOGY, 2022, 28 (26) : 3116 - 3131
  • [25] Optimization of hepatobiliary phase imaging in gadoxetic acid-enhanced magnetic resonance imaging: a narrative review
    Wang, Chao
    Yuan, Xiao-Dong
    Wu, Ning
    Sun, Wei-Rong
    Tian, Yuan
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2023, 13 (03) : 1972 - 1982
  • [26] Gadoxetic acid-enhanced magnetic resonance imaging significantly influences the clinical course in patients with colorectal liver metastases
    Mulder, B. G. Sibinga
    Visser, K.
    Feshtali, S.
    Vahrmeijer, A. L.
    Swijnenburg, R. J.
    Hartgrink, H. H.
    van den Boom, R.
    Burgmans, M. C.
    Mieog, J. S. D.
    BMC MEDICAL IMAGING, 2018, 18
  • [27] A Case of Hyperintense Liver Metastases of Breast Cancer in the Hepatobiliary Phase on Gadoxetic Acid-Enhanced Magnetic Resonance Imaging
    Yamaguchi, Tomoyuki
    Oura, Shoji
    Honda, Mariko
    Makimoto, Shinichiro
    CASE REPORTS IN ONCOLOGY, 2020, 13 (02): : 973 - 978
  • [28] Gadoxetic acid-enhanced magnetic resonance imaging significantly influences the clinical course in patients with colorectal liver metastases
    B. G. Sibinga Mulder
    K. Visser
    S. Feshtali
    A. L. Vahrmeijer
    R. J. Swijnenburg
    H. H. Hartgrink
    R. van den Boom
    M. C. Burgmans
    J. S. D. Mieog
    BMC Medical Imaging, 18
  • [29] Can gadoxetic acid-enhanced magnetic resonance imaging be used to avoid liver biopsy in patients with nonalcoholic fatty liver disease?
    Amorim, Viviane Brandao
    Parente, Daniella Braz
    Paiva, Fernando Fernandes
    Oliveira Neto, Jaime Araujo
    Miranda, Amanda Almeida
    Moreira, Claudia Cravo
    Fernandes, Flavia Ferreira
    Ferreira Campos, Carlos Frederico
    Leite, Nathalie Carvalho
    Perez, Renata de Mello
    Rodrigues, Rosana Souza
    WORLD JOURNAL OF HEPATOLOGY, 2020, 12 (09) : 661 - 671
  • [30] Gadoxetic acid-enhanced dynamic magnetic resonance imaging using optimized integrated combination of compressed sensing and parallel imaging technique
    Kawai, Nobuyuki
    Goshim, Satoshi
    Noda, Yoshifumi
    Kajita, Kimihiro
    Kawada, Hiroshi
    Tanahashi, Yukichi
    Nagata, Shoma
    Matsuo, Masayuki
    MAGNETIC RESONANCE IMAGING, 2019, 57 : 111 - 117