Ultrasound simulation of real-time temperature estimation during radiofrequency ablation using finite element models

被引:11
|
作者
Daniels, M. J. [1 ,2 ]
Jiang, J. [1 ]
Varghese, T. [1 ]
机构
[1] Univ Wisconsin, Dept Med Phys, Madison, WI 53706 USA
[2] Univ Wisconsin, Dept Phys, Madison, WI 53706 USA
关键词
ablation; elastography; elasticity; imaging; radiofrequency ablation; strain; speed of sound; thermal strain; thermal expansion; temperature imaging; thermal imaging; ultrasound; finite element analysis;
D O I
10.1016/j.ultras.2007.10.005
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Radiofrequency ablation is the most common minimally invasive therapy used in the United States to treat hepatocellular carcinoma and liver metastases. The ability to perform real-time temperature imaging while a patient is undergoing ablation therapy may help reduce the high recurrence rates following ablation therapy. Ultrasound echo signals undergo time shifts with increasing temperature due to sound speed and thermal expansion, which are tracked using both 1D cross correlation and 2D block matching based speckle tracking methods. In this paper, we present a quantitative evaluation of the accuracy and precision of temperature estimation using the above algorithms on both simulated and experimental data. A finite element analysis simulation of radiofrequency ablation of hepatic tissue was developed. Finite element analysis provides a method to obtain the exact temperature distribution along with a mapping of the tissue displacement due to thermal expansion. These local displacement maps were combined with the displacement due to speed of sound changes and utilized to generate ultrasound radiofrequency frames at specified time increments over the entire ablation procedure. These echo signals provide an ideal test-bed to evaluate the performance of both speckle tracking methods, since the estimated temperature results can be compared directly to the exact finite element solution. Our results indicate that the 1D cross-correlation (CC) method underestimates the cumulative displacement by 0.20 mm, while the underestimation with 2D block matching (BM) is about 0.14 mm after 360 s of ablation. The 1D method also overestimates the size of the ablated region by 5.4% when compared to 2.4% with the 2D method after 720 s of ablation. Hence 2D block matching provides better tracking of temperature variations when compared to the 1D cross-correlation method over the entire duration of the ablation procedure. In addition, results obtained using 1D cross-correlation diverge from the ideal finite element results after 7 min of ablation and for temperatures greater than 65 degrees C. In a similar manner, experimental results presented using a tissue-mimicking phantom also demonstrate that the maximum percent difference with 2D block matching was 5%, when compared to 31% with the 1D method over the 700 s heating duration on the phantom. (C) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:40 / 55
页数:16
相关论文
共 50 条
  • [41] Real-time ultrasound imaging simulation
    Aiger, D
    Cohen-Or, D
    REAL-TIME IMAGING, 1998, 4 (04) : 263 - 274
  • [42] APPROACHES TO THE ESTIMATION OF FETAL WEIGHT USING REAL-TIME ULTRASOUND
    DUDLEY, NJ
    COPPING, C
    BRITISH JOURNAL OF RADIOLOGY, 1986, 59 (703): : 734 - 734
  • [43] Control of real-time MRI with a 3D-controller during radiofrequency ablation
    Zurawka, Vanessa
    Hoffmann, Ruediger
    Burgert, Oliver
    MEDICAL IMAGING 2018: IMAGE-GUIDED PROCEDURES, ROBOTIC INTERVENTIONS, AND MODELING, 2018, 10576
  • [44] Optimizing Electrode Placement Using Finite-Element Models in Radiofrequency Ablation Treatment Planning
    Chen, Chun-Cheng R.
    Miga, Michael I.
    Galloway, Robert L., Jr.
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2009, 56 (02) : 237 - 245
  • [45] Finite Volume and Finite Element Models for Real-Time Control and State Estimation of Two-Dimensional Heat Transfer Processes
    Rauh, Andreas
    Senkel, Luise
    Aschemann, Harald
    2014 19TH INTERNATIONAL CONFERENCE ON METHODS AND MODELS IN AUTOMATION AND ROBOTICS (MMAR), 2014, : 600 - 605
  • [46] Real-time FDG PET Guidance during Biopsies and Radiofrequency Ablation Using Multimodality Fusion with Electromagnetic Navigation
    Venkatesan, Aradhana M.
    Kadoury, Samuel
    Abi-Jaoudeh, Nadine
    Levy, Elliot B.
    Maass-Moreno, Roberto
    Kruecker, Jochen
    Dalal, Sandeep
    Xu, Sheng
    Glossop, Neil
    Wood, Bradford J.
    RADIOLOGY, 2011, 260 (03) : 848 - 856
  • [47] Clinical evaluation of in silico planning and real-time simulation of hepatic radiofrequency ablation (ClinicIMPPACT Trial)
    Michael Moche
    Harald Busse
    Jurgen J. Futterer
    Camila A. Hinestrosa
    Daniel Seider
    Philipp Brandmaier
    Marina Kolesnik
    Sjoerd Jenniskens
    Roberto Blanco Sequeiros
    Gaber Komar
    Mika Pollari
    Martin Eibisberger
    Horst Rupert Portugaller
    Philip Voglreiter
    Ronan Flanagan
    Panchatcharam Mariappan
    Martin Reinhardt
    European Radiology, 2020, 30 : 934 - 942
  • [48] Clinical evaluation of in silico planning and real-time simulation of hepatic radiofrequency ablation (ClinicIMPPACT Trial)
    Moche, Michael
    Busse, Harald
    Futterer, Jurgen J.
    Hinestrosa, Camila A.
    Seider, Daniel
    Brandmaier, Philipp
    Kolesnik, Marina
    Jenniskens, Sjoerd
    Blanco Sequeiros, Roberto
    Komar, Gaber
    Pollari, Mika
    Eibisberger, Martin
    Portugaller, Horst Rupert
    Voglreiter, Philip
    Flanagan, Ronan
    Mariappan, Panchatcharam
    Reinhardt, Martin
    EUROPEAN RADIOLOGY, 2020, 30 (02) : 934 - 942
  • [49] Real-time Conductivity Imaging of Temperature and Tissue Property Changes During Radiofrequency Ablation: An Ex Vivo Model Using Weighted Frequency Difference
    Wi, Hun
    McEwan, Alistair Lee
    Lam, Vincent
    Kim, Hyung Joong
    Woo, Eung Je
    Oh, Tong In
    BIOELECTROMAGNETICS, 2015, 36 (04) : 277 - 286
  • [50] GPU-Based Real-Time Approximation of the Ablation Zone for Radiofrequency Ablation
    Rieder, Christian
    Kroeger, Tim
    Schumann, Christian
    Hahn, Horst K.
    IEEE TRANSACTIONS ON VISUALIZATION AND COMPUTER GRAPHICS, 2011, 17 (12) : 1812 - 1821