Blind separation of cardiac components and extraction of input function from H215O dynamic myocardial PET using independent component analysis

被引:0
|
作者
Lee, JS
Lee, DS
Ahn, JY
Cheon, GJ
Kim, SK
Yeo, JS
Seo, K
Park, KS
Chung, JK
Lee, MC
机构
[1] Seoul Natl Univ, Coll Med, Dept Nucl Med, Chongno Ku, Seoul 110799, South Korea
[2] Seoul Natl Univ, Coll Med, Dept Biomed Engn, Seoul 110799, South Korea
关键词
PET; independent component analysis; myocardial blood flow;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The independent component analysis (ICA) method is suggested to be useful for separation of the ventricles and the myocardium and for extraction of the left ventricular input function from the dynamic (H2O)-O-15 myocardial PET. The ICA-generated input function was validated with the sampling method, and the myocardial blood flow (MBF) calculated with this input function was compared with the microsphere results. Methods: We assumed that the elementary activities of the ventricular pools and the myocardium were spatially independent and that the mixture of them composed dynamic PET image frames. The independent components were estimated by recursively minimizing the mutual information (measure of dependence) between the components. The ICA-generated input functions were compared with invasively derived arterial blood samples. Moreover, the regional MBF calculated using the ICA-generated input functions and single-compartment model was correlated with the results obtained from the radiolabeled microspheres. Results: The ventricles and the myocardium were successfully separated in all cases within a short computation time (<15 s). The ICA-generated input functions displayed shapes similar to those obtained by arterial sampling except that they had a smoother tail than those obtained by sampling, which meant that ICA removed the statistical noise from the time-activity curves. The ICA-generated input function showed a longer time delay of peaks than those obtained by arterial sampling. MBFs estimated using the ICA-generated input functions ranged from 1.10 to approximately 2.52 mL/min/g at rest and from 1.69 to approximately 8.00 mL/min/g after stress and correlated well with those calculated with microspheres (y = 0.45 + 0.98x; r = 0.95, P < 0.000). Conclusion: ICA, a rapid and reliable method for extraction of the pure physiologic components, was a valid and useful method for quantification of the regional MBF using (H2O)-O-15 PET.
引用
收藏
页码:938 / 943
页数:6
相关论文
共 48 条
  • [1] Blind separation of cardiac components and extraction of input function from H215O dynamic myocardial PET using independent component analysis:: A validation study.
    Lee, JS
    Ahn, JY
    Lee, DS
    Kim, SK
    Chun, GJ
    Kang, KW
    Jang, MJ
    Lee, TW
    Park, KS
    Chung, JK
    Lee, MC
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2000, 41 (05) : 98P - 98P
  • [2] Robust extraction of input function from H215O dynamic myocardial positron emission tomography using independent component analysis
    Lee, JS
    Ahn, JY
    Lee, DS
    Han, J
    Jang, MJ
    Chung, JK
    Lee, MC
    Park, KS
    [J]. 1999 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1-3, 1999, : 990 - 994
  • [3] Extraction of input function from H215O PET imaging of rat heart
    Kudomi, N.
    Sipila, H.
    Autio, A.
    Oikonen, V.
    Liljenback, H.
    Tarkia, M.
    Laivola, J.
    Johansson, J.
    Teras, M.
    Roivainen, A.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2011, 38 : S266 - S266
  • [4] Parametric image of RMBF using factor analysis and cluster analysis on H215O dynamic myocardial PET.
    Lee, JS
    Ahn, JY
    Lee, DS
    Kim, SK
    Park, KS
    Chung, JK
    Lee, MC
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2000, 41 (05) : 98P - 98P
  • [5] Parametric image of myocardial blood flow generated from dynamic H215O PET using factor analysis and cluster analysis
    J. S. Lee
    D. S. Lee
    J. Y. Ahn
    G. J. Cheon
    S. -K. Kim
    J. S. Yeo
    K. S. Park
    J. -K. Chung
    M. C. Lee
    [J]. Medical and Biological Engineering and Computing, 2005, 43 : 678 - 685
  • [6] ICA Based Automatic Segmentation of Dynamic H215O Cardiac PET Images
    Margadan-Mendez, Margarita
    Juslin, Anu
    Nesterov, Sergey V.
    Kalliokoski, Kari
    Knuuti, Juhani
    Ruotsalainen, Ulla
    [J]. IEEE TRANSACTIONS ON INFORMATION TECHNOLOGY IN BIOMEDICINE, 2010, 14 (03): : 795 - 802
  • [7] Noninvasive estimation of cerebral blood flow using image-derived carotid input function in H215O dynamic PET
    Kim, KM
    Watabe, H
    Shidahara, M
    Ahn, JY
    Choi, S
    Kudomi, N
    Hayashida, K
    Miyake, Y
    Iida, H
    [J]. 2001 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORDS, VOLS 1-4, 2002, : 1282 - 1285
  • [8] A Nonlinear Variational Method for Improved Quantification of Myocardial Blood Flow Using Dynamic H215O PET
    Benning, Martin
    Koesters, Thomas
    Wuebbeling, Frank
    Schaefers, Klaus
    Burger, Martin
    [J]. 2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 3746 - +
  • [9] Generation of MBF parametric image from H215O dynamic myocardial PET using linear least squares method.
    Lee, JS
    Ahn, JY
    Lee, DS
    Iida, H
    Kim, KM
    Yeo, JS
    Cheon, GJ
    Kim, SK
    Park, KS
    Chung, JK
    Lee, MC
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2001, 42 (05) : 59P - 59P
  • [10] Comparison of Image Segmentation and Registration Based Methods for Analysis of Misaligned Dynamic H215O Cardiac PET Images
    Juslin, Anu
    Tohka, Jussi
    Lotjonen, Jyrki
    Ruotsalainen, Ulla
    [J]. 2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 3200 - 3204