Parametric image of myocardial blood flow generated from dynamic H215O PET using factor analysis and cluster analysis

被引:0
|
作者
J. S. Lee
D. S. Lee
J. Y. Ahn
G. J. Cheon
S. -K. Kim
J. S. Yeo
K. S. Park
J. -K. Chung
M. C. Lee
机构
[1] Seoul National University College of Medicine,Department of Nuclear Medicine
[2] Seoul National University College of Medicine,Department of Biomedical Engineering
关键词
PET; H; O; Myocardial blood flow; Parametric image; Cluster analysis;
D O I
暂无
中图分类号
学科分类号
摘要
Algorithm-based parametric imaging of myocardial blood flow (MBF), as measured by H215O PET, has been the goal of many research efforts. A method for generating parametric images of regional MBF by factor and cluster analysis on H215O dynamic myocardial PET was validated by its comparison with gold-standard MBF values determined invasively using radiolabelled microspheres. Right and left ventricular blood pool activities and their factor images were obtained by the application of factor analysis to dynamic frames. By subtraction of the factor images multiplied by their corresponding values on the factors from the original dynamic images for each frame, pure tissue dynamic images were obtained, from which arterial blood activities were excluded. Cluster analysis that averaged pixels having time-activity curves with the same shape was applied to pure tissue images to generate parametric MBF images. The usefulness of this method for quantifying regional MBF was evaluated using canine experiment data. H215O PET scans and microsphere studies were performed on seven dogs at rest and after pharmacological stress. The image qualities and the contrast of parametric images obtained using the proposed method were significantly improved over either the tissue factor images or the parametric images obtained using a conventional method. Regional MBFs obtained using the proposed method correlated well with those obtained by the region of interest method (r=0.94) and by the microsphere technique (r=0.90). A non-invasive method is presented for generating parametric images of MBF from H215O PET, using factor and cluster analysis.
引用
收藏
页码:678 / 685
页数:7
相关论文
共 50 条
  • [1] Parametric image of RMBF using factor analysis and cluster analysis on H215O dynamic myocardial PET.
    Lee, JS
    Ahn, JY
    Lee, DS
    Kim, SK
    Park, KS
    Chung, JK
    Lee, MC
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2000, 41 (05) : 98P - 98P
  • [2] Parametric image of myocardial blood flow generated from dynamic H215OPET using factor analysis and cluster analysis
    Lee, JS
    Lee, DS
    Ahn, JY
    Cheon, GJ
    Kim, SK
    Yeo, JS
    Park, KS
    Chung, JK
    Lee, MC
    [J]. MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2005, 43 (05) : 678 - 685
  • [3] Generation of parametric image of regional myocardial blood flow using H215O dynamic PET and a linear least-squares method
    Lee, JS
    Lee, DS
    Ahn, JY
    Yeo, JS
    Cheon, GJ
    Kim, SK
    Park, KS
    Chung, JK
    Lee, MC
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2005, 46 (10) : 1687 - 1695
  • [4] Improved parametric images of blood flow and vascular volume by cluster analysis in H215O brain PET study
    Kim, KM
    Watabe, H
    Hayashi, T
    Iida, H
    [J]. QUANTITATION IN BIOMEDICAL IMAGING WITH PET AND MRI, 2004, (1265): : 79 - 83
  • [5] Noise reduction of parametric images of myocardial blood flow by filtering H215O dynamic PET images using wavelet transform
    Chung, SH
    Lee, JS
    Lee, DS
    Park, KS
    [J]. 2002 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-3, 2003, : 1341 - 1343
  • [6] A Nonlinear Variational Method for Improved Quantification of Myocardial Blood Flow Using Dynamic H215O PET
    Benning, Martin
    Koesters, Thomas
    Wuebbeling, Frank
    Schaefers, Klaus
    Burger, Martin
    [J]. 2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 3746 - +
  • [7] Generation of MBF parametric image from H215O dynamic myocardial PET using linear least squares method.
    Lee, JS
    Ahn, JY
    Lee, DS
    Iida, H
    Kim, KM
    Yeo, JS
    Cheon, GJ
    Kim, SK
    Park, KS
    Chung, JK
    Lee, MC
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2001, 42 (05) : 59P - 59P
  • [8] Mapping of local renal blood flow with PET and H215O
    Alpert, NM
    Rabito, CA
    Correia, DJA
    Babich, JW
    Littman, BH
    Tompkins, RG
    Rubin, NT
    Rubin, RH
    Fischman, AJ
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2002, 43 (04) : 470 - 475
  • [9] Imaging myocardial viability and blood flow using a single H215O PET-CT scan
    Harms, H. J.
    Knaapen, P.
    De Haan, S.
    Lammertsma, A. A.
    Lubberink, M.
    [J]. EUROPEAN HEART JOURNAL SUPPLEMENTS, 2011, 13 (0A) : A68 - A68
  • [10] Cardiac VUer: Software for semiautomatic generation of parametric myocardial blood flow images from a H215O PET-CT scan
    Harms, Hendrik
    Knaapen, Paul
    Raijmakers, Pieter
    Lammertsma, Adriaan
    Lubberink, Mark
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2010, 51