Correction of ambient temperature measurement by thermocouple

被引:0
|
作者
Moisson, M [1 ]
Trombe, A [1 ]
机构
[1] Complexe Sci Rangueil, Dept Civil Engn, Thermal & Mech Lab, INSA,UPS, F-31077 Toulouse, France
关键词
D O I
10.1080/08916159808946567
中图分类号
O414.1 [热力学];
学科分类号
摘要
This aim of this study is to assess the error caused by solar radiation in real-site ambient temperature measurements obtained with a thermocouple and to determine a correction method. The results show that the high values of solar radiation that may occur in highly glazed spaces can have a significant influence on thermocouple measurements. The authors therefore decided to validate and develop a corrective model of the measurement error based on an energy balance of the sensor The influence of the various parameters was studied and the most important error was found to occur when solar fluxes were neglected. They therefore propose a simplified equation to correct the error measurement.
引用
收藏
页码:299 / 315
页数:17
相关论文
共 50 条
  • [21] Temperature measurement system based on thermocouple with controlled temperature field
    Kochan, O.
    Kochan, R.
    Bojko, O.
    Chyrka, M.
    IDAACS 2007: PROCEEDINGS OF THE 4TH IEEE WORKSHOP ON INTELLIGENT DATA ACQUISITION AND ADVANCED COMPUTING SYSTEMS: TECHNOLOGY AND APPLICATIONS, 2007, : 47 - +
  • [22] Analysis of surrounding gas temperature influence on thermocouple measurement temperature
    Liu, Budong
    Huang, Qinhuang
    Wang, Peiyong
    10TH ASIAN-PACIFIC CONFERENCE ON AEROSPACE TECHNOLOGY AND SCIENCE & THE 4TH ASIAN JOINT SYMPOSIUM ON AEROSPACE ENGINEERING (APCATS'2019 /AJSAE'2019), 2020, 1509
  • [23] Temperature measurement by thermocouple probe: influences of variable fluid velocity on the dynamic characteristics of thermocouple
    Yang, Zhaoxin
    Meng, Xiaofeng
    PROCEEDINGS OF THE 2ND INTERNATIONAL CONFERENCE ON ELECTRONIC & MECHANICAL ENGINEERING AND INFORMATION TECHNOLOGY (EMEIT-2012), 2012, 23
  • [24] Thermocouple for temperature measurement of the pressured fluidized bed (PFB)
    Jiang, Shouguo
    Li, Hongshou
    Yibiao Jishu Yu Chuanganqi/Instrument Technique and Sensor, (02): : 31 - 33
  • [25] MEASUREMENT OF FLAME TEMPERATURE WITH A MULTI-ELEMENT THERMOCOUPLE
    DE, DS
    JOURNAL OF THE INSTITUTE OF ENERGY, 1981, 54 (419): : 113 - 116
  • [26] Decreasing of thermocouple inhomogeneity impact on temperature measurement error
    Institute of Compute Science, Yangtze University, Nanhuan Road No.1, Jingzhou, Hubei, 434023, China
    不详
    不详
    Sensors Transducers, 2013, 12 (509-513):
  • [27] Effects of thermocouple electrical insulation on the measurement of surface temperature
    AlWaaly, Ahmed A. Y.
    Paul, Manosh C.
    Dobson, Phillip S.
    APPLIED THERMAL ENGINEERING, 2015, 89 : 421 - 431
  • [28] Influence of thermocouple angles and wire distance on temperature measurement
    Li, Xingyou
    Li, Luqiang
    Huang, Qinghuang
    Wang, Peiyong
    CASE STUDIES IN THERMAL ENGINEERING, 2023, 49
  • [29] MEASUREMENT OF DRILLING TEMPERATURE BY GARTER SPRING THERMOCOUPLE METHOD
    DEVRIES, MF
    WU, SM
    MITCHELL, JW
    MICROTECNIC, 1967, 21 (06): : 583 - &
  • [30] Mathematical Study of Temperature Measurement by Thermocouple in Chemical Processes
    Iskandarov, Nabi
    ORIENTAL JOURNAL OF CHEMISTRY, 2022, 38 (03) : 547 - 554