Thermally driven adsorption cooling and desalination employing multi-bed dual-evaporator system

被引:24
|
作者
Ali, Syed Muztuza [1 ]
Haider, Patrick [2 ]
Sidhu, Dalminder S. [2 ]
Chakraborty, Anutosh [1 ]
机构
[1] Nanyang Technol Univ, Sch Mech & Aerosp Engn, 50 Nanyang Ave, Singapore 639798, Singapore
[2] Tech Univ Munich, Dept Chem, Lichtenbergstr 4, D-85748 Garching, Germany
基金
新加坡国家研究基金会;
关键词
Adsorption; Cooling; Desalination; Dual evaporator; Mass recovery; Multi-bed adsorption; AIR-CONDITIONING SYSTEM; LIFE-CYCLE COST; SILICA-GEL; WATER; PERFORMANCE; CHILLER; SIMULATION; HYBRID; HEAT; PUMP;
D O I
10.1016/j.applthermaleng.2016.06.045
中图分类号
O414.1 [热力学];
学科分类号
摘要
In this paper, an advanced adsorption cooling cum desalination system comprising four adsorption beds and two evaporators is, presented. The proposed system continuously produces desalinated water in the condenser and chilled water at two different temperature levels. It employs silica gel as adsorbent and water as adsorbate pair. One evaporator is operated at low pressure for low temperature cooling (approximate to 10 degrees C) while the pressure of the other evaporator is set higher for sufficient desalination and cooling water production at high temperature (approximate to 120 degrees C). The proposed system is simulated with two different configurations. In the first configuration each evaporator is connected to only two beds, whereas in the second configuration, all beds are connected to both evaporators for consecutive low pressure and high pressure adsorption. Both configurations are compared with conventional system in regards of specific cooling power for the two temperature levels (SCP-L and SCP-H), specific daily water production (SDWP), performance ratio (PR), coefficient of performance (COP) and overall conversion ratio (OCR). It is found that the proposed system with the second configuration outperforms the conventional 4 bed system by 45% and 40% in terms of SDWP and OCR. Further, the flexibility of the system is proven by the variation of timing schemes, leading to an adjustment in SCP and SDWP depending on the fresh water and cooling energy demands. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1136 / 1147
页数:12
相关论文
共 36 条
  • [1] Numerical simulation and theoretical investigation of a multi-cycle dual-evaporator adsorption desalination and cooling system
    Naeimi, Ali
    Nowee, Seyed Mostafa
    Amiri, Hossein Ali Akhlaghi
    [J]. CHEMICAL ENGINEERING RESEARCH & DESIGN, 2020, 156 : 402 - 413
  • [2] Performance analysis of a continuous multi-bed adsorption rotary cooling system
    Yong, L
    Sumathy, K
    [J]. APPLIED THERMAL ENGINEERING, 2005, 25 (2-3) : 393 - 407
  • [3] Waste heat driven dual-mode, multi-stage, multi-bed regenerative adsorption system
    Saha, BB
    Koyama, S
    Kashiwagi, T
    Akisawa, A
    Ng, KC
    Chua, HT
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2003, 26 (07): : 749 - 757
  • [4] Modeling study of two-stage, multi-bed air cooled silica gel plus water adsorption cooling cum desalination system
    Mitra, Sourav
    Thu, Kyaw
    Saha, Bidyut Baran
    Srinivasan, Kandadai
    Dutta, Pradip
    [J]. APPLIED THERMAL ENGINEERING, 2017, 114 : 704 - 712
  • [5] Analysis of selected designs of a multi-bed adsorption refrigeration system
    Neska, Miroslaw
    Opara, Tadeusz
    Majcher, Andrzej
    [J]. PRZEMYSL CHEMICZNY, 2024, 103 (01): : 73 - 78
  • [6] Performance investigation of a waste heat-driven 3-bed 2-evaporator adsorption cycle for cooling and desalination
    Thu, Kyaw
    Saha, Bidyut Baran
    Chua, Kian Jon
    Ng, Kim Choon
    [J]. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2016, 101 : 1111 - 1122
  • [7] Adsorption desalination-cooling system employing copper sulfate driven by low grade heat sources
    Ali, Ehab S.
    Askalany, Ahmed A.
    Harby, K.
    Diab, Mohamed Refaat
    Alsaman, Ahmed S.
    [J]. APPLIED THERMAL ENGINEERING, 2018, 136 : 169 - 176
  • [8] Study on a dual-mode, multi-stage, multi-bed regenerative adsorption chiller
    Saha, Bidyut B.
    Koyama, Shigeru
    Ng, Kim Choon
    Hamamoto, Yoshinori
    Akisawa, Atsushi
    Kashiwagi, Takao
    [J]. RENEWABLE ENERGY, 2006, 31 (13) : 2076 - 2090
  • [9] Study on solar/waste heat driven multi-bed adsorption chiller with mass recovery
    Khan, M. Z. I.
    Saha, B. B.
    Alam, K. C. A.
    Akisawa, A.
    Kashiwagi, T.
    [J]. RENEWABLE ENERGY, 2007, 32 (03) : 365 - 381
  • [10] Performance evaluation of multi-stage, multi-bed adsorption chiller employing re-heat scheme
    Khan, M. Z. I.
    Alam, K. C. A.
    Saha, B. B.
    Akisawa, A.
    Kashiwagi, T.
    [J]. RENEWABLE ENERGY, 2008, 33 (01) : 88 - 98