Study on a dual-mode, multi-stage, multi-bed regenerative adsorption chiller

被引:58
|
作者
Saha, Bidyut B.
Koyama, Shigeru
Ng, Kim Choon
Hamamoto, Yoshinori
Akisawa, Atsushi
Kashiwagi, Takao
机构
[1] Kyushu Univ, Inst Mat Chem & Engn, Kasuga, Fukuoka 8168580, Japan
[2] Natl Univ Singapore, Dept Mech Engn, Singapore 119260, Singapore
[3] Tokyo Univ Agr & Technol, Bio Applicat & Syst Engn, Koganei, Tokyo 1848588, Japan
关键词
adsorption; dual-mode; multi-bed; parametric study; silica gel-water; solar energy utilization;
D O I
10.1016/j.renene.2005.10.003
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In this paper, a detailed parametric study on a dual-mode silica gel-water adsorption chiller is performed. This advanced adsorption chiller utilizes effectively low-temperature solar or waste heat sources of temperature between 40 and 95 degrees C. Two operation modes are possible for the advanced chiller. The first operation mode will be to work as a highly efficient conventional chiller where the driving source temperature is between 60 and 95 degrees C. The second operation mode will be to work as an advanced three-stage adsorption chiller where the available driving source temperature is very low (between 40 and 60 degrees C). With this very low driving source temperature in combination with a coolant at 30 degrees C, no other cycle except an advanced adsorption cycle with staged regeneration will be operational. In this paper, the effect of chilled-water inlet temperature, heat transfer fluid flow rates and adsorption-desorption cycle time effect on cooling capacity and COP of the dual-mode chiller is performed. Simulation results show that both cooling capacity and COP values increase with the increase of chilled water inlet temperature with driving source temperature at 50 and 80 degrees C in three-stage mode, and single-stage multi-bed mode, respectively. However, the delivered chilled-water temperature increases with chilled-water inlet temperature in both modes. (c) 2005 Elsevier Ltd. All rights reserved.
引用
收藏
页码:2076 / 2090
页数:15
相关论文
共 50 条
  • [1] Waste heat driven dual-mode, multi-stage, multi-bed regenerative adsorption system
    Saha, BB
    Koyama, S
    Kashiwagi, T
    Akisawa, A
    Ng, KC
    Chua, HT
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2003, 26 (07): : 749 - 757
  • [2] Performance evaluation of multi-stage, multi-bed adsorption chiller employing re-heat scheme
    Khan, M. Z. I.
    Alam, K. C. A.
    Saha, B. B.
    Akisawa, A.
    Kashiwagi, T.
    [J]. RENEWABLE ENERGY, 2008, 33 (01) : 88 - 98
  • [3] Study on solar/waste heat driven multi-bed adsorption chiller with mass recovery
    Khan, M. Z. I.
    Saha, B. B.
    Alam, K. C. A.
    Akisawa, A.
    Kashiwagi, T.
    [J]. RENEWABLE ENERGY, 2007, 32 (03) : 365 - 381
  • [4] Multi-bed regenerative adsorption chiller - improving the utilization of waste heat and reducing the chilled water outlet temperature fluctuation
    Chua, HT
    Ng, KC
    Malek, A
    Kashiwagi, T
    Akisawa, A
    Saha, BB
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2001, 24 (02): : 124 - 136
  • [5] Study on a solar heat driven dual-mode adsorption chiller
    Habib, Khairul
    Choudhury, Biplab
    Chatterjee, Pradip Kumar
    Saha, Bidyut Baran
    [J]. ENERGY, 2013, 63 : 133 - 141
  • [6] Waste heat driven multi-bed adsorption chiller: Heat exchangers overall thermal conductance on chiller performance
    Saha, BB
    El-Sharkawy, II
    Koyama, S
    Lee, JB
    Kuwahara, K
    [J]. HEAT TRANSFER ENGINEERING, 2006, 27 (05) : 80 - 87
  • [7] Performance evaluation of a low-temperature waste heat driven multi-bed adsorption chiller
    Saha, BB
    Koyama, S
    Lee, JB
    Kuwahara, K
    Alam, KCA
    Hamamoto, Y
    Akisawa, A
    Kashiwagi, T
    [J]. INTERNATIONAL JOURNAL OF MULTIPHASE FLOW, 2003, 29 (08) : 1249 - 1263
  • [8] Multi-stage dual-mode cross-slotted superconducting filters for telecommunication application
    Cassinese, A
    Barra, A
    Panariello, G
    Vaglio, R
    [J]. 2001 IEEE MTT-S INTERNATIONAL MICROWAVE SYMPOSIUM DIGEST, VOLS 1-3, 2001, : 491 - 494
  • [9] Multi-bed regenerative adsorption chiller - Improving the utilization of waste heat and reducing the chilled water outlet temperature fluctuation (vol 24, pg 124, 2001)
    Chua, H. T.
    Ng, K. C.
    Malek, A.
    Kashiwagi, T.
    Akisawa, A.
    Saha, B. B.
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2007, 30 (07): : 1290 - 1290
  • [10] Multi-stage fluidized bed column: Hydrodynamic study
    Singh, Abhinandan
    Verma, Rupesh
    Kishore, Kaushal
    Verma, Nishith
    [J]. CHEMICAL ENGINEERING AND PROCESSING-PROCESS INTENSIFICATION, 2008, 47 (05) : 957 - 970