Cerebral aneurysm hemodynamics modeling from 3D rotational angiography

被引:0
|
作者
Cebral, JR [1 ]
Castro, MA [1 ]
Burgess, JE [1 ]
Putman, CM [1 ]
机构
[1] George Mason Univ, Sch Computat Sci, Fairfax, VA 22030 USA
关键词
D O I
暂无
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Detailed knowledge of the hemodynamics in cerebral aneurysms is valuable not only for understanding their formation and rupture but also for clinical evaluation and treatment. However, important hemodynamic quantities are difficult to measure in vivo. In this paper a patient-specific method for modeling the hemodynamics of cerebral aneurysms from in vivo anatomical images is described, and the flow patterns in various kinds of intracranial aneurysms are presented. These models will be used to explore possible relationships between the blood flow patterns and the location, size and taxonomy of the aneurysms.
引用
收藏
页码:944 / 947
页数:4
相关论文
共 50 条
  • [31] CT angiography versus 3D rotational angiography in patients with subarachnoid hemorrhage
    R. S. Bechan
    S. B. van Rooij
    M. E. Sprengers
    J. P. Peluso
    M. Sluzewski
    C. B. Majoie
    W. J. van Rooij
    Neuroradiology, 2015, 57 : 1239 - 1246
  • [32] CT angiography versus 3D rotational angiography in patients with subarachnoid hemorrhage
    Bechan, R. S.
    van Rooij, S. B.
    Sprengers, M. E.
    Peluso, J. P.
    Sluzewski, M.
    Majoie, C. B.
    van Rooij, W. J.
    NEURORADIOLOGY, 2015, 57 (12) : 1239 - 1246
  • [33] Morphodynamic Analysis of Cerebral Aneurysm Pulsation From Time-Resolved Rotational Angiography
    Zhang, Chong
    Villa-Uriol, Maria-Cruz
    De Craene, Mathieu
    Pozo, Jose M.
    Frangi, Alejandro F.
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2009, 28 (07) : 1105 - 1116
  • [34] Evaluation of the perforators of the anterior communicating artery (AComA) using routine cerebral 3D rotational angiography
    Lescher, Stephanie
    Zimmermann, Maja
    Konczalla, Juergen
    Deller, Thomas
    Porto, Luciana
    Seifert, Volker
    Berkefeld, Joachim
    JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2016, 8 (10) : 1061 - +
  • [35] Utility of 3D rotational angiography road map in flow diverter deployment in a distal dissecting MCA aneurysm
    Rustemi, Oriela
    Di Clemente, Loris
    Raneri, Fabio
    Volpin, Lorenzo
    Iannucci, Giuseppe
    NEUROSURGICAL FOCUS, 2019, 46
  • [36] Low-Dose 3D Rotational Angiography in Measuring the Size of Intracranial Aneurysm: In Vitro Feasibility Study Using Aneurysm Phantom
    Ki, Hee Jong
    Kim, Bum-Soo
    Kim, Jun-Ki
    Choi, Jai Ho
    Shin, Yong Sam
    Choi, Yangsean
    Shin, Na-Young
    Jang, Jinhee
    Ahn, Kook-jin
    NEUROINTERVENTION, 2021, 16 (01) : 59 - 63
  • [37] Rapid prototyping airway and vascular models from 3D rotational angiography: Beans to cup 3D printing
    Zablah, Jenny E.
    Rodriguez, Salvador A.
    Jacobson, Nicholas
    Morgan, Gareth J.
    PROGRESS IN PEDIATRIC CARDIOLOGY, 2021, 63
  • [38] Anatomical variations of the anterior cerebral arterial circle visualized by multidetector computed tomography angiography: Comparison with 3D rotational angiography
    Ferre, Jean-Christophe
    Niederberger, Emilie
    Morandi, Xavier
    Raoult, Helene
    Carsin-Nicol, Beatrice
    Gauvrit, Jean-Yves
    JOURNAL OF NEURORADIOLOGY, 2013, 40 (02) : 112 - 120
  • [39] Middle cerebral artery branch occlusion mimicking a saccular aneurysm on 3D digital subtraction angiography
    Pearl, Monica Smith
    Tamargo, Rafael
    Gailloud, Philippe
    JOURNAL OF NEUROSURGERY, 2008, 109 (06) : 1123 - 1125
  • [40] Evaluation of the lenticulostriate arteries with rotational angiography and 3D reconstruction
    Kang, HS
    Han, MH
    Kwon, BJ
    Kwon, OK
    Kim, SH
    Chang, KH
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2005, 26 (02) : 306 - 312