Kinetic investigation of the planar multipole resonance probe under arbitrary pressure

被引:1
|
作者
Wang, Chunjie [1 ]
Friedrichs, Michael [2 ]
Oberrath, Jens [2 ]
Brinkmann, Ralf Peter [1 ]
机构
[1] Ruhr Univ Bochum, Inst Theoret Elect Engn, D-44780 Bochum, Germany
[2] South Westphalia Univ Appl Sci, Dept Elect Power Engn, D-59494 Soest, Germany
来源
PLASMA SOURCES SCIENCE & TECHNOLOGY | 2022年 / 31卷 / 10期
关键词
planar multipole resonance probe; kinetic effects; collision-less damping; collisional damping;
D O I
10.1088/1361-6595/ac915a
中图分类号
O35 [流体力学]; O53 [等离子体物理学];
学科分类号
070204 ; 080103 ; 080704 ;
摘要
A new plasma diagnostic tool called planar multipole resonance probe (pMRP) has been proposed in the past decade. It has a minimally invasive structure and allows simultaneous measurement of electron density, temperature, and collision frequency. Previous work has investigated the behavior of the pRMP by the Drude model, which misses kinetic effects, and the collisionless kinetic model, which misses collisional damping. To further study the pMRP at arbitrary pressure, a collisional kinetic model is proposed in this paper. The electron dynamics is described by the kinetic equation, which considers the electron-neutral elastic collision. Under the electrostatic approximation, the kinetic equation is coupled to the Poisson equation. The real part of the general complex admittance is calculated to describe the spectral response of the probe-plasma system. The calculated spectra of the idealized pMRP demonstrate that this collisional kinetic model can capture both collisionless kinetic damping and collisional damping. This model overcomes the limitations of the Drude model and the collisionless kinetic model and allows discussion of the validity of simpler models.
引用
收藏
页数:13
相关论文
共 50 条
  • [31] The Multipole Resonance Probe-based controller: a technology to investigate plasma-based deposition
    Woelfel, C.
    Oberberg, M.
    Berger, B.
    Engel, D.
    Brinkmann, R. P.
    Awakowicz, P.
    Lunze, J.
    Schulze, J.
    [J]. JOURNAL OF INSTRUMENTATION, 2019, 14 (10):
  • [32] Investigation of Fano resonance in planar metamaterial with perturbed periodicity
    Pu, Mingbo
    Hu, Chenggang
    Huang, Cheng
    Wang, Changtao
    Zhao, Zeyu
    Wang, Yanqin
    Luo, Xiangang
    [J]. OPTICS EXPRESS, 2013, 21 (01): : 992 - 1001
  • [33] KINETIC-STUDY OF LOW-PRESSURE H-2 MULTIPOLE DISCHARGE
    JACQUIN, D
    BRETAGNE, J
    FERDINAND, R
    [J]. PLASMA CHEMISTRY AND PLASMA PROCESSING, 1989, 9 (02) : 165 - 188
  • [34] Planar electrochromatography in a closed system under pressure - Pressurized planar electrochromatography
    Dzido, Tadeusz H.
    Plocharz, Pawel W.
    [J]. JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2007, 30 (18) : 2651 - 2667
  • [35] KINETIC INVESTIGATION OF HYDROGENATION OF ETHYLENE ON POROUS AND NON-POROUS PLATINUM CATALYSTS UNDER PRESSURE
    BUELLA, F
    FOLKL, P
    MOGER, D
    SZAKACS, S
    [J]. MAGYAR KEMIAI FOLYOIRAT, 1978, 84 (02): : 86 - 90
  • [36] INVESTIGATION OF THE SHEATH EFFECT ON THE RESONANCE FREQUENCIES OF A CURLING PROBE
    Arshadi, Ali
    Brinkmann, Ralf Peter
    [J]. 2015 42ND IEEE INTERNATIONAL CONFERENCE ON PLASMA SCIENCES (ICOPS), 2015,
  • [37] KINETIC INVESTIGATION OF GLUTAMATE-DEHYDROGENASE SELF-ASSOCIATION UNDER HIGH-PRESSURE
    FITOS, I
    HEREMANS, K
    [J]. REACTION KINETICS AND CATALYSIS LETTERS, 1979, 12 (04): : 399 - 403
  • [38] Rarefied gas flow in a planar channel caused by arbitrary pressure and temperature drops
    Titarev, V. A.
    [J]. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2012, 55 (21-22) : 5916 - 5930
  • [39] THE POSITIVELY BIASED PLANAR LANGMUIR PROBE IN A HIGH-PRESSURE PLASMA
    CLEMENTS, RM
    SMY, PR
    [J]. JOURNAL OF PHYSICS D-APPLIED PHYSICS, 1993, 26 (11) : 1916 - 1920
  • [40] The Nuclear Magnetic Resonance Probe Based on a Printed Circuit Board Planar Microcoil
    Wu, Wei Ping
    Lu, Rong Sheng
    Zhou, Xin Long
    Ni, Zhong Hua
    [J]. 2013 IEEE International Conference on Applied Superconductivity and Electromagnetic Devices (ASEMD), 2013, : 169 - 172