Nitrite amperometric sensor for gunshot residue screening

被引:35
|
作者
Promsuwan, Kiattisak [1 ,2 ,3 ]
Kanatharana, Proespichaya [1 ,2 ,3 ]
Thavarungkul, Panote [1 ,2 ,4 ]
Limbut, Warakorn [1 ,2 ,5 ]
机构
[1] Prince Songkla Univ, Ctr Excellence Trace Anal & Biosensor, Hat Yai 90112, Songkhla, Thailand
[2] Prince Songkla Univ, Fac Sci, Ctr Excellence Innovat Chem, Hat Yai 90112, Songkhla, Thailand
[3] Prince Songkla Univ, Fac Sci, Dept Chem, Hat Yai 90112, Songkhla, Thailand
[4] Prince Songkla Univ, Fac Sci, Dept Phys, Hat Yai 90112, Songkhla, Thailand
[5] Prince Songkla Univ, Fac Sci, Dept Appl Sci, Hat Yai 90112, Songkhla, Thailand
关键词
Pd particle-glassy carbon microspheres (Pd-GCMs); Nitrite; Gunshot residue; Flow injection amperometric detection; GLASSY-CARBON ELECTRODE; FLOW-INJECTION ANALYSIS; REDUCED GRAPHENE OXIDE; ELECTROCHEMICAL SENSOR; SENSITIVE DETECTION; HYDROGEN-PEROXIDE; QUANTUM DOTS; NANOPARTICLES; PALLADIUM; NITRATE;
D O I
10.1016/j.electacta.2019.135309
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
A novel electrochemical sensor comprising a glassy carbon electrode modified with a composite of palladium (Pd) particles and glassy carbon microspheres (GCMs), has been developed to detect gunshot residue via nitrite determination. Pd-GCMs was synthesized through a simple electroless deposition method and characterized by scanning electron microscopy and energy-dispersive X-ray spectroscopy. The electrocatalytic response of nitrite on the Pd-GCMs/GCE is greatly enhanced relative to that on a GCMs/GCE and bare GCE. The applied potential, flow rate and sample volume of flow injection amperometric detection were optimized. The sensor displayed a linear response to nitrite between 0.10 mmol L-1 and 4.0 mmol L-1, with a limit of detection and quantification of 0.030 and 0.11 mmol L-1, respectively. It exhibited very good performance with excellent electrocatalytic activity and high sensitivity (500 +/- 5 mA mM(-1) cm(-2)). In addition, the electrochemical sensor presented good repeatability (RSD < 1.5%, n = 20), reproducibility (RSD = 1.4%, n = 6), and operational stability (RSD = 2.8%, n = 268), along with high sample throughput (165 samples h(-1)). The results of detecting nitrite in gunshot residue with this sensor were in good agreement with those obtained by the Griess method (P>0.05). With its good performance this sensor could be a viable alternative method for detecting nitrite to identify gunshot residue in forensic evaluations via nitrite detection. (c) 2019 Elsevier Ltd. All rights reserved.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Development of a novel nitrite amperometric sensor based on poly(toluidine blue) film electrode
    Chunhai Yang
    Junhui Xu
    Shengshui Hu
    Journal of Solid State Electrochemistry, 2007, 11 : 514 - 520
  • [22] Evaluation of Total Nitrite Pattern Visualization as an Improved Method for Gunshot Residue Detection and its Application to Casework Samples
    Berger, Jason
    Upton, Colin
    Springer, Elyah
    JOURNAL OF FORENSIC SCIENCES, 2019, 64 (01) : 218 - 222
  • [23] Identification of gunshot residue: a critical review
    Romolo, FS
    Margot, P
    FORENSIC SCIENCE INTERNATIONAL, 2001, 119 (02) : 195 - 211
  • [24] GUNSHOT RESIDUE AND RANGE OF FIRE - REPLY
    WILBER, CG
    AMERICAN JOURNAL OF FORENSIC MEDICINE AND PATHOLOGY, 1992, 13 (02): : 176 - 177
  • [25] A survey of gunshot residue analysis methods
    Singer, RL
    Davis, D
    Houck, MM
    JOURNAL OF FORENSIC SCIENCES, 1996, 41 (02) : 195 - 198
  • [26] TEM-study of gunshot residue
    Kijek, M
    Bloeck, U
    Su, D
    Giersig, M
    EUROPEAN JOURNAL OF CELL BIOLOGY, 1997, 74 : 121 - 121
  • [27] GUNSHOT RESIDUE, 10 YEARS LATER
    GUILEYARDO, JM
    STONE, IC
    ODOM, CB
    AMERICAN JOURNAL OF FORENSIC MEDICINE AND PATHOLOGY, 1992, 13 (01): : 88 - 88
  • [28] GUNSHOT RESIDUE, 10 YEARS LATER
    WILBER, CG
    LANTZ, RK
    SULIK, PL
    AMERICAN JOURNAL OF FORENSIC MEDICINE AND PATHOLOGY, 1991, 12 (03): : 204 - 206
  • [29] FEI DEBUTS SEMs FOR GUNSHOT RESIDUE
    Arnaud, Celia H.
    Thayer, Ann M.
    CHEMICAL & ENGINEERING NEWS, 2009, 87 (39) : 68 - 68
  • [30] The persistence of gunshot residue on shooters' hands
    Jalanti, T
    Henchoz, P
    Gallusser, A
    Bonfanti, MS
    SCIENCE & JUSTICE, 1999, 39 (01) : 48 - 52