Nitrite amperometric sensor for gunshot residue screening

被引:35
|
作者
Promsuwan, Kiattisak [1 ,2 ,3 ]
Kanatharana, Proespichaya [1 ,2 ,3 ]
Thavarungkul, Panote [1 ,2 ,4 ]
Limbut, Warakorn [1 ,2 ,5 ]
机构
[1] Prince Songkla Univ, Ctr Excellence Trace Anal & Biosensor, Hat Yai 90112, Songkhla, Thailand
[2] Prince Songkla Univ, Fac Sci, Ctr Excellence Innovat Chem, Hat Yai 90112, Songkhla, Thailand
[3] Prince Songkla Univ, Fac Sci, Dept Chem, Hat Yai 90112, Songkhla, Thailand
[4] Prince Songkla Univ, Fac Sci, Dept Phys, Hat Yai 90112, Songkhla, Thailand
[5] Prince Songkla Univ, Fac Sci, Dept Appl Sci, Hat Yai 90112, Songkhla, Thailand
关键词
Pd particle-glassy carbon microspheres (Pd-GCMs); Nitrite; Gunshot residue; Flow injection amperometric detection; GLASSY-CARBON ELECTRODE; FLOW-INJECTION ANALYSIS; REDUCED GRAPHENE OXIDE; ELECTROCHEMICAL SENSOR; SENSITIVE DETECTION; HYDROGEN-PEROXIDE; QUANTUM DOTS; NANOPARTICLES; PALLADIUM; NITRATE;
D O I
10.1016/j.electacta.2019.135309
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
A novel electrochemical sensor comprising a glassy carbon electrode modified with a composite of palladium (Pd) particles and glassy carbon microspheres (GCMs), has been developed to detect gunshot residue via nitrite determination. Pd-GCMs was synthesized through a simple electroless deposition method and characterized by scanning electron microscopy and energy-dispersive X-ray spectroscopy. The electrocatalytic response of nitrite on the Pd-GCMs/GCE is greatly enhanced relative to that on a GCMs/GCE and bare GCE. The applied potential, flow rate and sample volume of flow injection amperometric detection were optimized. The sensor displayed a linear response to nitrite between 0.10 mmol L-1 and 4.0 mmol L-1, with a limit of detection and quantification of 0.030 and 0.11 mmol L-1, respectively. It exhibited very good performance with excellent electrocatalytic activity and high sensitivity (500 +/- 5 mA mM(-1) cm(-2)). In addition, the electrochemical sensor presented good repeatability (RSD < 1.5%, n = 20), reproducibility (RSD = 1.4%, n = 6), and operational stability (RSD = 2.8%, n = 268), along with high sample throughput (165 samples h(-1)). The results of detecting nitrite in gunshot residue with this sensor were in good agreement with those obtained by the Griess method (P>0.05). With its good performance this sensor could be a viable alternative method for detecting nitrite to identify gunshot residue in forensic evaluations via nitrite detection. (c) 2019 Elsevier Ltd. All rights reserved.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] A REVIEW OF THE METHODS FOR NITRITE DETERMINATION IN GUNSHOT RESIDUE
    SWARNER, S
    JOURNAL OF THE FORENSIC SCIENCE SOCIETY, 1988, 28 (04): : 268 - 268
  • [2] A SENSITIVE ELECTROCHEMICAL METHOD FOR THE ANALYSIS OF NITRITE ION AND METALS IN GUNSHOT RESIDUE
    BOHANNAN, EW
    VANGALEN, DA
    JOURNAL OF FORENSIC SCIENCES, 1991, 36 (03) : 886 - 893
  • [3] Rapid, selective and quantitative determination of nitrite and nitrate ions with capillary electrophoresis:: A new screening tool for gunshot residue detection
    Romolo, FS
    Trettene, M
    Bortolotti, F
    Schütz, F
    Tagliaro, F
    FORENSIC SCIENCE INTERNATIONAL, 2003, 136 : 147 - 147
  • [4] AMPEROMETRIC DETERMINATION OF SODIUM-NITRITE BY A MICROBIAL SENSOR
    KARUBE, I
    OKADA, T
    SUZUKI, S
    SUZUKI, H
    HIKUMA, M
    YASUDA, T
    EUROPEAN JOURNAL OF APPLIED MICROBIOLOGY AND BIOTECHNOLOGY, 1982, 15 (02): : 127 - 132
  • [5] Fabrication of a Disposable Amperometric Sensor for the Determination of Nitrite in Food
    Liu, Chao
    Chen, Daoming
    Zhu, Chunnan
    Liu, Xiaojun
    Wang, Yu
    Lu, Yuepeng
    Zheng, Dongyun
    Fu, Baorong
    MICROMACHINES, 2023, 14 (03)
  • [6] A novel nitrite amperometric sensor and its application in food analysis
    Yang, Chunhai
    Lu, Qing
    Hu, Shengshui
    ELECTROANALYSIS, 2006, 18 (22) : 2188 - 2193
  • [7] Nitrate and Nitrite Determination in Gunshot Residue Samples by Capillary Electrophoresis in Acidic Run Buffer
    Erol, Ozge O.
    Erdogan, Behice Y.
    Onar, Atiye N.
    JOURNAL OF FORENSIC SCIENCES, 2017, 62 (02) : 423 - 427
  • [8] A nitrite sensor based on a highly sensitive nitrite reductase mediator-coupled amperometric detection
    Strehlitz, B
    Grundig, B
    Schumacher, W
    Kroneck, PMH
    Vorlop, KD
    Kotte, H
    ANALYTICAL CHEMISTRY, 1996, 68 (05) : 807 - 816
  • [9] STUDIES OF GUNSHOT RESIDUE
    GISLASON, J
    PATE, BD
    JOURNAL OF RADIOANALYTICAL CHEMISTRY, 1973, 15 (01): : 103 - 113
  • [10] A Case Report of Hypotension and Methemoglobinemia Associated With Gunshot Residue Poisoning: Nitrite-Induced Methemoglobinemia
    Pugh, David B.
    Saxena, Aakash
    Barta, Lauren E.
    Pinkerton, Carolyn
    Bajic, Jurica
    Boettcher, Brent T.
    Woehlck, Harvey J.
    A & A PRACTICE, 2022, 16 (10): : E01631