Effect of alloy type and casting technique on the fracture strength of implant-cemented structures

被引:10
|
作者
Castillo-de Oyaguee, Raquel [1 ]
Osorio, Raquel [2 ]
Lynch, Christopher [3 ]
Gilmour, Alan [3 ]
Toledano, Manuel [2 ]
机构
[1] Univ Complutense Madrid, Dept Prosthodont, Fac Dent, UCM, E-28040 Madrid, Spain
[2] Univ Granada UGR, Dept Dent, Sch Dent, Granada 18071, Spain
[3] Cardiff Univ, Dept Adult Dent Hlth, Sch Dent, Cardiff CF14 4XY, S Glam, Wales
来源
关键词
Metallic framework; titanium; cobalt-chromium; casting technique; fracture strength; CERAMIC RESTORATIONS; SUPPORTED PROSTHESES; DENTURE FRAMEWORKS; COMMERCIALLY PURE; TITANIUM; CASTABILITY; RESISTANCE; DESIGNS;
D O I
10.4317/medoral.16.e619
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: To evaluate the influence of alloy type and casting procedure on the fracture strength (FS) of metallic frameworks for implant-supported fixed prostheses. Study design: Thirty three-unit structures for lower posterior bridges were waxed-up and randomly assigned to two groups (n=15) according to alloy type and casting technique: Group 1 (C): cobalt-chromium cast in a centrifugal machine (TS1, Degussa-Huls); Group 2 (T): titanium cast in a pressure-differential device (Cyclarc II, Morita). Each structure was cemented onto two prefabricated abutments under a constant seating pressure. After 6 months of water aging, samples were loaded in a static universal testing machine (EFH/5/FR, Microtest) until fracture. Axial compressive loads were applied at the central fossa of the pontics. FS data were recorded and surface topography of the fractured connectors was SEM-analyzed. A Chi-Square test was performed to assess the dependence of pores on the alloy type and casting procedure. ANOVA and Student-Newman-Keuls (SNK) tests were run for FS comparisons (p<0.05). Results: One third of the C structures showed pores inside the fractured connectors. T frameworks demonstrated higher FS than that of C specimens exhibiting pores (p=0.025). C samples containing no pores recorded the greatest mean FS (p<0.001). Conclusions: Fracture strength of metallic frameworks depended on the alloy type and casting procedure. Cobalt-chromium casts often registered pores inside the connectors, which strongly decreased the fracture resistance. An accurate casting of titanium with a pressure-differential system may result in the most predictable technique under the tested experimental conditions.
引用
收藏
页码:E619 / E625
页数:7
相关论文
共 50 条
  • [21] The effect of nickel on the structure, mechanical and casting properties of aluminium alloy of 7075 type
    Belov, NA
    Zolotorevskiy, VS
    ALUMINUM ALLOYS 2002: THEIR PHYSICAL AND MECHANICAL PROPERTIES PTS 1-3, 2002, 396-4 : 935 - 940
  • [22] COMPARISON OF EFFECT OF CAVITY DESIGN ON FRACTURE STRENGTH OF 3 DENTAL ALLOY SYSTEMS
    YATES, JL
    HEMBREE, JH
    MCKNIGHT, JP
    JOURNAL OF DENTISTRY FOR CHILDREN, 1976, 43 (03): : 51 - 55
  • [23] Effects of binder type and dosage on the mode I fracture toughness of cemented paste backfill-related structures
    Huang, Shaoping
    Yan, Echuan
    Fang, Kun
    Li, Xingming
    CONSTRUCTION AND BUILDING MATERIALS, 2021, 270
  • [24] Study of melting-casting process of a new type ultra-high strength aluminum alloy
    Lu, Zheng
    Yang, Shou-jie
    Jiang, Hai-feng
    Lu, Jian
    Hangkong Cailiao Xuebao/Journal of Aeronautical Materials, 2000, 20 (04): : 30 - 33
  • [25] Effect of electric current pulse on tensile strength and elongation of casting ZA27 alloy
    Gao, M
    He, GH
    Yang, F
    Guo, JD
    Yuan, ZX
    Zhou, BL
    MATERIALS SCIENCE AND ENGINEERING A-STRUCTURAL MATERIALS PROPERTIES MICROSTRUCTURE AND PROCESSING, 2002, 337 (1-2): : 110 - 114
  • [26] Effect of fatigue loading on the fracture strength and failure mode of lithium disilicate and zirconia implant abutments
    Elsayed, Adham
    Wille, Sebastian
    Al-Akhali, Majed
    Kern, Matthias
    CLINICAL ORAL IMPLANTS RESEARCH, 2018, 29 (01) : 20 - 27
  • [27] Effect of Fabrication Method on Fracture Strength of Provisional Implant-Supported Fixed Dental Prostheses
    Suralik, Kelly M.
    Sun, Jie
    Chen, Chia-Yu
    Lee, Sang J.
    PROSTHESIS, 2020, 2 (04): : 325 - 332
  • [28] Effect of type of coarse aggregate on the strength properties and fracture energy of normal and high strength concrete
    Vishalakshi, K. P.
    Revathi, V.
    Reddy, S. Sivamurthy
    ENGINEERING FRACTURE MECHANICS, 2018, 194 : 52 - 60
  • [29] EFFECT OF IRRADIATION ON THE ULTIMATE FRACTURE STRENGTH OF THE ALLOY ZR-2.5-PERCENT NB
    SHATSKAYA, OA
    RIVKIN, EY
    VASNIN, AM
    KLYUSHIN, VV
    KOZLOV, AV
    NALESNIK, VM
    RODIN, ME
    SOVIET ATOMIC ENERGY, 1979, 47 (01): : 519 - 522
  • [30] Effect of metal type and surface treatment on in vitro tensile strength of copings cemented to minimally retentive preparations
    Abreu, Amara
    Loza, Maria A.
    Elias, Augusto
    Mukhopadhyay, Siuli
    Rueggeberg, Frederick A.
    JOURNAL OF PROSTHETIC DENTISTRY, 2007, 98 (03): : 199 - 207