A Fully Implantable Stimulator With Wireless Power and Data Transmission for Experimental Investigation of Epidural Spinal Cord Stimulation

被引:45
|
作者
Xu, Qi [1 ,2 ]
Hu, Dingyin [1 ,2 ]
Duan, Bingyu [3 ]
He, Jiping [1 ,2 ,4 ]
机构
[1] Huazhong Univ Sci & Technol, Minist Educ, Key Lab Image Proc & Intelligent Control, Wuhan 430074, Peoples R China
[2] Huazhong Univ Sci & Technol, Sch Automat, Wuhan 430074, Peoples R China
[3] Huazhong Univ Sci & Technol, Tongji Med Coll, Dept Anat, Wuhan 430030, Peoples R China
[4] Arizona State Univ, Sch Biol & Hlth Syst Engn, Tempe, AZ 85287 USA
关键词
Epidural spinal cord stimulation (ESCS); implantable stimulator; inductive link; rat; wireless transmission; NEUROMUSCULAR STIMULATION; SYSTEM; RATS; ANIMALS; MODULATION; MOVEMENTS; DEVICE;
D O I
10.1109/TNSRE.2015.2396574
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Epidural spinal cord stimulation (ESCS) combined with partial weight-bearing therapy (PWBT) has been shown to facilitate recovery of functional walking for individuals after spinal cord injury (SCI). The investigation of neural mechanisms of recovery from SCI under this treatment has been conducted broadly in rodent models, yet a suitable ESCS system is still unavailable. This paper describes a practical, programmable, and fully implantable stimulator for laboratory research on rats to explore fundamental neurophysiological principles for functional recovery after SCI. The ESCS system is composed of a personal digital assistant (PDA), an external controller, an implantable pulse generator (IPG), lead extension, and stimulating electrodes. The stimulation parameters can be programmed and adjusted through a graphical user interface on the PDA. The external controller is placed on the rat back and communicates with the PDA via radio-frequency (RF) telemetry. An RF carrier from the class-E power amplifier in the external controller provides both data and power for the IPG through an inductive link. The IPG is built around a microcontroller unit to generate voltage-regulated pulses delivered to the bipolar electrode for ESCS in rats. The encapsulated IPG measures 22 mm x 23 mm x 7 mm with a mass of similar to 3.78 g. This fully implantable batteryless stimulator provided a simplified and efficient method to carry out chronic experiments in untethered animals for medical electro-neurological research.
引用
收藏
页码:683 / 692
页数:10
相关论文
共 47 条
  • [11] Magnet Free Inductive Wireless Power and Data Transmission System for Fully Implantable Cochlear Implants
    Dogan, Mert
    Turkyilmaz, Ayse Beyhan
    Engur, Yasemin
    Kulah, Haluk
    PROCEEDINGS OF THE 29TH ACM/IEEE INTERNATIONAL SYMPOSIUM ON LOW POWER ELECTRONICS AND DESIGN, ISLPED 2024, 2024,
  • [12] A Fully Implantable Miniaturized Liquid Crystal Polymer (LCP)-Based Spinal Cord Stimulator for Pain Control
    Yun, Seunghyeon
    Koh, Chin Su
    Seo, Jungmin
    Shim, Shinyong
    Park, Minkyung
    Jung, Hyun Ho
    Eom, Kyungsik
    Chang, Jin Woo
    Kim, Sung June
    SENSORS, 2022, 22 (02)
  • [13] Studies of the influence of the degradation of the capacitances of an inductively coupled oscillator circuit on the characteristics of the wireless power supply module of an implantable spinal cord stimulator
    Mindubaev, E. A.
    BIOMEDICAL ENGINEERING, 2024, 58 (02) : 115 - 118
  • [14] Design of wireless power and data transmission circuits for implantable biomicrosystem
    Laboratory of Electronics and Technology of Information , Department of Electrical Engineering, National Engineers School of Sfax, B.P. W, Sfax, Tunisia 3038, Tunisia
    Biotechnology, 2007, 2 (153-164)
  • [15] Electronic Design for An Implantable Wireless Power and Data Transmission System
    Zou, Kui
    Li, Xiuhan
    Hu, Jinbin
    Zhang, Haixia
    2008 9TH INTERNATIONAL CONFERENCE ON SOLID-STATE AND INTEGRATED-CIRCUIT TECHNOLOGY, VOLS 1-4, 2008, : 2581 - +
  • [16] A microcontroller-based implantable neuromuscular stimulation system with wireless power and data transmission for animal experiments
    Liang, CK
    Young, GS
    Chen, JJJ
    Chen, CK
    JOURNAL OF THE CHINESE INSTITUTE OF ENGINEERS, 2003, 26 (04) : 493 - 501
  • [17] Studies of the influence of implantation depth on the output characteristics of the wireless energy supply module of an implantable spinal cord stimulator
    Mindubaev, E. A.
    BIOMEDICAL ENGINEERING, 2024, 58 (03) : 189 - 191
  • [18] Chronic, Battery-Free, Fully Implantable Multimodal Spinal Cord Stimulator for Pain Modulation in Small Animal Models
    Widman, Allie J.
    Bashar, Taron
    Burton, Alex
    Clausen, David Marshall
    Gupta, Prashant
    Wolf, Drew K.
    Folarin-Hines, Jakayla
    Payne, Maria
    Rogers, John A.
    Meacham, Kathleen W.
    Gereau, Robert W.
    Gutruf, Philipp
    ADVANCED SCIENCE, 2025,
  • [19] Micro Scale Implantable Bioelectronic Interfaces for Targeted Nerve Stimulation and Ultra Low Power Wireless Data Transmission
    Riley, Morgan
    Tala, Fnu
    Bandali, Mehdi
    Johnson, Katherine J.
    Johnson, Benjamin C.
    2024 IEEE WORKSHOP ON MICROELECTRONICS AND ELECTRON DEVICES, WMED, 2024, : 21 - 21
  • [20] VLSI implementation of wireless power and data transmission circuits for micro-stimulator
    Lee, SY
    Lee, SC
    Chen, JJJ
    2003 INTERNATIONAL SYMPOSIUM ON VLSI TECHNOLOGY, SYSTEMS, AND APPLICATIONS, PROCEEDINGS OF TECHNICAL PAPERS, 2003, : 164 - 167