A Fully Implantable Stimulator With Wireless Power and Data Transmission for Experimental Investigation of Epidural Spinal Cord Stimulation

被引:45
|
作者
Xu, Qi [1 ,2 ]
Hu, Dingyin [1 ,2 ]
Duan, Bingyu [3 ]
He, Jiping [1 ,2 ,4 ]
机构
[1] Huazhong Univ Sci & Technol, Minist Educ, Key Lab Image Proc & Intelligent Control, Wuhan 430074, Peoples R China
[2] Huazhong Univ Sci & Technol, Sch Automat, Wuhan 430074, Peoples R China
[3] Huazhong Univ Sci & Technol, Tongji Med Coll, Dept Anat, Wuhan 430030, Peoples R China
[4] Arizona State Univ, Sch Biol & Hlth Syst Engn, Tempe, AZ 85287 USA
关键词
Epidural spinal cord stimulation (ESCS); implantable stimulator; inductive link; rat; wireless transmission; NEUROMUSCULAR STIMULATION; SYSTEM; RATS; ANIMALS; MODULATION; MOVEMENTS; DEVICE;
D O I
10.1109/TNSRE.2015.2396574
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Epidural spinal cord stimulation (ESCS) combined with partial weight-bearing therapy (PWBT) has been shown to facilitate recovery of functional walking for individuals after spinal cord injury (SCI). The investigation of neural mechanisms of recovery from SCI under this treatment has been conducted broadly in rodent models, yet a suitable ESCS system is still unavailable. This paper describes a practical, programmable, and fully implantable stimulator for laboratory research on rats to explore fundamental neurophysiological principles for functional recovery after SCI. The ESCS system is composed of a personal digital assistant (PDA), an external controller, an implantable pulse generator (IPG), lead extension, and stimulating electrodes. The stimulation parameters can be programmed and adjusted through a graphical user interface on the PDA. The external controller is placed on the rat back and communicates with the PDA via radio-frequency (RF) telemetry. An RF carrier from the class-E power amplifier in the external controller provides both data and power for the IPG through an inductive link. The IPG is built around a microcontroller unit to generate voltage-regulated pulses delivered to the bipolar electrode for ESCS in rats. The encapsulated IPG measures 22 mm x 23 mm x 7 mm with a mass of similar to 3.78 g. This fully implantable batteryless stimulator provided a simplified and efficient method to carry out chronic experiments in untethered animals for medical electro-neurological research.
引用
收藏
页码:683 / 692
页数:10
相关论文
共 47 条
  • [1] A Fully Implantable Stimulator with Wireless Power and Data Transmission for Experimental Use in Epidural Spinal Cord Stimulation
    Xu, Qi
    Li, Jun
    Han, Wenjuan
    Zhou, Houlun
    2011 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2011, : 7230 - 7233
  • [2] A fully implanted programmable stimulator based on wireless communication for epidural spinal cord stimulation in rats
    Zhou, Hui
    Xu, Qi
    He, Jiping
    Ren, Hangkong
    Zhou, Houlun
    Zheng, Kejia
    JOURNAL OF NEUROSCIENCE METHODS, 2012, 204 (02) : 341 - 348
  • [3] A Fully Implantable and Programmable Epidural Spinal Cord Stimulation System for Rats With Spinal Cord Injury
    Mao, Guangwei
    Zhou, Zhijun
    Su, Hao
    Chen, Yaozhong
    Zhang, Jianjun
    Zhang, Chiyuan
    Wang, Zhigong
    Lu, Xiaoying
    IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2023, 31 : 818 - 828
  • [4] A Fully Implantable and Programmable Epidural Spinal Cord Stimulation System for Rats With Spinal Cord Injury
    Mao, Guangwei
    Zhou, Zhijun
    Su, Hao
    Chen, Yaozhong
    Zhang, Jianjun
    Zhang, Chiyuan
    Wang, Zhigong
    Lu, Xiaoying
    IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2023, 31 : 818 - 828
  • [5] VLSI implementation of implantable wireless power and data transmission micro-stimulator for neuromuscular stimulation
    Lee, SY
    Lev, SC
    Chen, JJJ
    IEICE TRANSACTIONS ON ELECTRONICS, 2004, E87C (06) : 1062 - 1068
  • [6] A One-time Implantable Wireless Power Bidirectional Transmission Spinal Cord Stimulation System
    Wang, Chua-Chin
    Hsu, Chia-Hao
    Tseng, Shao-Bin
    Shmilovitz, Doron
    2010 INTERNATIONAL SYMPOSIUM ON VLSI DESIGN AUTOMATION AND TEST (VLSI-DAT), 2010, : 288 - 291
  • [7] A versatile microprocessor-based multichannel stimulator for experimental use in epidural spinal cord stimulation
    Xu, Q
    He, JP
    Wang, YJ
    Xu, T
    Huang, J
    2005 FIRST INTERNATIONAL CONFERENCE ON NEURAL INTERFACE AND CONTROL PROCEEDINGS, 2005, : 205 - 208
  • [8] Flexible and fully implantable upconversion device for wireless optogenetic stimulation of the spinal cord in behaving animals
    Wang, Ying
    Xie, Kai
    Yue, Haibing
    Chen, Xian
    Luo, Xuan
    Liao, Qinghai
    Liu, Ming
    Wang, Feng
    Shi, Peng
    NANOSCALE, 2020, 12 (04) : 2406 - 2414
  • [9] Patient acceptance of techniques for prolonging battery life in fully implantable spinal cord stimulator systems
    Royal, MA
    Wienecke, G
    Movva, V
    Riley, J
    ANNALS OF NEUROLOGY, 2000, 48 (03) : 431 - 431
  • [10] Wireless Data and Power Transfer of an Optogenetic Implantable Visual Cortex Stimulator
    Fattah, Nabeel
    Laha, Soumyasanta
    Sokolov, Danil
    Chester, Graeme
    Degenaar, Patrick
    2015 37TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2015, : 8006 - 8009