Helium-3 diffusion MR imaging of the human lung over multiple time scales

被引:15
|
作者
Mugler, John P., III [1 ,2 ]
Wang, Chengbo [3 ]
Miller, G. Wilson [1 ]
Cates, Gordon D., Jr. [1 ,4 ]
Mata, Jaime F. [1 ]
Brookeman, James R. [1 ,2 ]
de lange, Eduard E. [1 ]
Altes, Talissa A. [1 ,3 ]
机构
[1] Univ Virginia, Sch Med, Dept Radiol, Ctr In Vivo Hyperpolarized Gas MR Imaging, Charlottesville, VA 22908 USA
[2] Univ Virginia, Sch Med, Dept Biomed Engn, Charlottesville, VA 22908 USA
[3] Childrens Hosp Philadelphia, Dept Radiol, Philadelphia, PA 19104 USA
[4] Univ Virginia, Dept Phys, Charlottesville, VA 22901 USA
关键词
MRI of lung; diffusion MRI; hyperpolarized helium;
D O I
10.1016/j.acra.2007.10.009
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives. Diffusion magnetic resonance imaging (MRI) with hyperpolarized He-3 gas is a powerful technique for probing the characteristics of the lung microstructure. A key parameter for this technique is the diffusion time, which is the period during which the atoms are allowed to diffuse within the lung for measurement of the signal attenuation. The relationship between diffusion time and the length scales that can be explored is discussed, and representative, preliminary results are presented from ongoing studies of the human lung for diffusion times ranging from milliseconds to several seconds. Materials and Methods. He-3 diffusion MRI of the human lung was performed on a 1.5T Siemens Sonata scanner. Using gradient echo-based and stimulated echo-based techniques for short and medium-to-long diffusion times, respectively, measurements were performed for times ranging from 2 milliseconds to 6.5 seconds in two healthy subjects, a subject with subclinical chronic obstructive pulmonary disease and a subject with bronchopulmonary dysplasia. Results. In healthy subjects, the apparent diffusion coefficient decreased by about 10-fold, from approximately 0.2 to 0.02 cm(2)/second, as the diffusion time increased from approximately 1 millisecond to 1 second. Results in subjects with disease suggest that measurements made at diffusion times substantially longer than 1 millisecond may provide improved sensitivity for detecting certain pathologic changes in the lung microstructure. Conclusions. With appropriately designed pulse sequences it is possible to explore the diffusion of hyperpolarized 3He in the human lung over more than a 1,000-fold variation of the diffusion time. Such measurements provide a new opportunity for exploring and characterizing the microstructure of the healthy and diseased lung.
引用
收藏
页码:693 / 701
页数:9
相关论文
共 50 条
  • [21] Assessment of in vitro vs. in vivo lung structure using hyperpolarized helium-3 diffusion magnetic resonance imaging
    Mata, Jaime F.
    Altes, Talissa A.
    Ruppert, Kai
    Hagspiel, Klaus D.
    Miller, Grady W.
    Brookeman, James R.
    Mugler, John P., III
    MAGNETIC RESONANCE IMAGING, 2009, 27 (06) : 845 - 851
  • [22] Measurement of Large Airways Using Dynamic 3D Hyperpolarized Helium-3 MR Imaging
    Peterson, E. T.
    Holmes, J. H.
    Dattawadkar, A.
    Agrawal, G.
    Dai, J.
    Jarjour, N. N.
    Fain, S. B.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2009, 179
  • [23] Regional Anisotropy of Airspace Orientation in the Lung as Assessed With Hyperpolarized Helium-3 Diffusion MRI
    Komlosi, Peter
    Altes, Talissa A.
    Qing, Kun
    Mooney, Karen E.
    Miller, G. Wilson
    Mata, Jaime F.
    de lange, Eduard E.
    Tobias, William A.
    Cates, Gordon D., Jr.
    Brookeman, James R.
    Mugler, John P., III
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2015, 42 (06) : 1777 - 1782
  • [24] Real time imaging of air trapping in COPD with hyperpolarized helium-3 MRI
    Wild, JM
    Swift, AJ
    Woodhouse, N
    Fichele, S
    Mills, GH
    Lawson, R
    Paley, MNJ
    Van Beek, EJR
    THORAX, 2003, 58 : 73 - 73
  • [25] Hyperpolarized Helium-3 Diffusion-weighted Magnetic Resonance Imaging Detects Abnormalities of Lung Structure in Children With Bronchopulmonary Dysplasia
    Flors, Lucia
    Mugler, John P., III
    Paget-Brown, Alix
    Froh, Deborah K.
    de Lange, Eduard E.
    Patrie, James T.
    Altes, Talissa A.
    JOURNAL OF THORACIC IMAGING, 2017, 32 (05) : 323 - 332
  • [26] Acinar determinants of the apparent diffusion coefficient for helium-3
    Verbanck, Sylvia
    Paiva, Manuel
    JOURNAL OF APPLIED PHYSIOLOGY, 2010, 108 (04) : 793 - 799
  • [27] Hyperpolarized helium-3 nuclear magnetic resonance imaging of human lungs.
    Bachert, P
    Schad, LR
    Bock, M
    Knopp, MV
    Ebert, M
    Grossmann, T
    Heil, W
    Hofmann, D
    Otten, EW
    Surkau, R
    vanKaick, G
    Lorenz, WJ
    JOURNAL OF NUCLEAR MEDICINE, 1996, 37 (05) : 1320 - 1320
  • [28] NMR imaging of thermally polarized helium-3 gas
    Kober, F
    Koenigsberg, B
    Belle, V
    Viallon, M
    Leviel, JL
    Delon, A
    Ziegler, A
    Décorps, M
    JOURNAL OF MAGNETIC RESONANCE, 1999, 138 (02) : 308 - 312
  • [29] Diffusion-Weighted Hyperpolarized Helium-3 Magnetic Resonance Imaging In Adult Cystic Fibrosis
    Kirby, M.
    Villemaire, L.
    Ahmed, H.
    Paterson, N. A.
    McCormack, D. G.
    Lewis, J. F.
    Parraga, G.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2013, 187
  • [30] Nuclear magnetic resonance imaging with hyperpolarised helium-3
    Ebert, M
    Grossmann, T
    Heil, W
    Otten, WE
    Surkau, R
    Leduc, M
    Bachert, P
    Knopp, MV
    Schad, LR
    Thelen, M
    LANCET, 1996, 347 (9011): : 1297 - 1299