Engineering an integrated system with a high pressure polymeric microfluidic chip coupled to liquid chromatography-mass spectrometry (LC-MS) for the analysis of abused drugs

被引:15
|
作者
Chen, Pin-Chuan [1 ,2 ]
Zhang, Wei-Zhe [1 ]
Chen, Wei-Ru [3 ]
Jair, Yung-Cheng [3 ]
Wu, Yi-Hsin [3 ]
Liu, Yi-Hsin [4 ]
Chen, Pei-Zhen [1 ]
Chen, Lian-Yu [5 ,6 ]
Chen, Pai-Shan [3 ]
机构
[1] Natl Taiwan Univ Scinece & Technol, Dept Mech Engn, Taipei, Taiwan
[2] Natl Taiwan Univ Scinece & Technol, High Speed 3D Printing Res Ctr, Taipei, Taiwan
[3] Natl Taiwan Univ, Inst Toxicol, Coll Med, Taipei, Taiwan
[4] Natl Taiwan Normal Univ, Dept Chem, Taipei, Taiwan
[5] Taipei City Hosp, Kunming Prevent & Control Ctr, Taipei, Taiwan
[6] Natl Taiwan Univ, Inst Epidemiol & Prevent Med, Taipei, Taiwan
关键词
Integrating microfluidics chip; Chromatography; LC-MS; Addictive polymeric; One-piece; Drugs of abuse; ON-A-CHIP; CONDUCTIVITY DETECTION; LAB; METABOLITES; SEPARATION; HPLC;
D O I
10.1016/j.snb.2021.130888
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A microfluidic chip coupled to a liquid chromatography-mass spectrometry (LC-MS) system is a powerful tool to determine components of interest in tracing biological samples. However, producing a reusable and robust chip having chromatographic separation for LC-MS systems remains analytically challenging due to the high back pressure generally occurring when microfluidic channels are packed particles. In this study, a one-piece and high-pressure-resistant polymeric microfluidic chip was fabricated by commercial stereolithographic 3D printing with an inner diameter of 1 mm, packed with 5 mu m diameter fluorophenyl propyl particles, and coupled to a regular LC-MS. The maximum pressure occurred up to 134 bar with a variation of 1 bar when using 70% methanol at a flow rate of 0.035 mL min(-1). Ten drugs and two drug metabolites were analyzed in 15 min under continuous pressure change by LC-MS. The limit of detection was between 2 and 20 ng mL(-1) in human urine. The coefficient of determination (R-2) was > 0.991. The shift of retention time of each peak was maintained at < 2%. After a chip was eluted with a high organic solvent composition (90% methanol/water and 90% acetonitrile/water mixture) and a high back pressure for continuously 45 h, the cross-sectional areas were investigated and results showed that the microfluidic chip remained intact. The overall experiment results showed that this platform had significant reproducibility, robustness and stability without contamination, demonstrating that this 3D printing microfluidic chip coupled with LC-MS is an efficient and precise tool for bioanalysis.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] Miniaturization of liquid chromatography coupled to mass spectrometry. 3. Achievements on chip-based LC-MS devices
    Vargas Medina, Deyber Arley
    Soares Maciel, Edvaldo Vasconcelos
    Lancas, Fernando Mauro
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2020, 131
  • [32] Detection of pacific ciguatoxins using liquid chromatography coupled to either low or high resolution mass spectrometry (LC-MS/MS)
    Sibat, Manoella
    Herrenknecht, Christine
    Darius, Helene Taiana
    Roue, Melanie
    Chinain, Mireille
    Hess, Philipp
    JOURNAL OF CHROMATOGRAPHY A, 2018, 1571 : 16 - 28
  • [33] SIMULTANEOUS DETECTION OF MULTICYTOTOXIC DRUGS ON OCCUPATIONAL ENVIRONMENT BY LIQUID CHROMATOGRAPHY-TANDEM MASS SPECTROMETRY (LC-MS/MS) ANALYSIS
    Ogawa, T.
    Yonemura, M.
    Kawasumi, K.
    Aoyagi, Y.
    Ueno, S.
    Ichida, Y.
    Ohe, Y.
    Endo, K.
    Izumi, K.
    ANNALS OF ONCOLOGY, 2012, 23 : 164 - 165
  • [34] Liquid chromatography and liquid chromatography-mass spectrometry/time of flight (LC-MS/TOF) studies on simvastatin and its degradation products
    Shah, R. P.
    Kumar, V.
    Singh, S.
    JOURNAL OF PHARMACY AND PHARMACOLOGY, 2008, 60 : A9 - A10
  • [35] Determination of free amino acids in plants by liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS)
    Dziagwa-Becker, Magdalena M.
    Marin Ramos, Jose M.
    Topolski, Jakub K.
    Oleszek, Wieslaw A.
    ANALYTICAL METHODS, 2015, 7 (18) : 7574 - 7581
  • [36] Determination of melatonin in bakery products using liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS)
    Zielinski, Henryk
    Szawara-Nowak, Dorota
    Wiczkowski, Wieslaw
    CHEMICAL PAPERS, 2017, 71 (06) : 1083 - 1089
  • [37] Liquid chromatography-mass spectrometry (LC-MS) investigation of the thiobarbituric acid reactive substances (TBARS) reaction
    Jardine, D
    Antolovich, M
    Prenzler, PD
    Robards, K
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2002, 50 (06) : 1720 - 1724
  • [38] Determination of organic pollutants in Anguilla anguilla by liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS)
    Vitale, Dyana
    Pico, Yolanda
    Alvarez-Ruiz, Rodrigo
    METHODSX, 2021, 8
  • [39] A tandem liquid chromatography-mass spectrometry (LC-MS) method for profiling small molecules in complex samples
    Pyke, James S.
    Callahan, Damien L.
    Kanojia, Komal
    Bowne, Jairus
    Sahani, Sheena
    Tull, Dedreia
    Bacic, Antony
    McConville, Malcolm J.
    Roessner, Ute
    METABOLOMICS, 2015, 11 (06) : 1552 - 1562
  • [40] Quantification of surfactant protein D (SPD) in human serum by liquid chromatography-mass spectrometry (LC-MS)
    Klont, Frank
    Pouwels, Simon D.
    Bults, Peter
    van de Merbel, Nico C.
    ten Hacken, Nick H. T.
    Horvatovich, Peter
    Bischof, Rainer
    TALANTA, 2019, 202 : 507 - 513