Implementation of New Cable Condition-Monitoring Technology at Oyster Creek Nuclear Generating Station

被引:2
|
作者
Kiger, C. J. [1 ]
Sexton, C. D. [1 ]
Hashemian, H. M. [1 ]
O'Hagan, R. D. [1 ]
Dormann, L. [2 ]
Wasfy, W. [2 ]
机构
[1] Anal & Measurement Serv Corp, AMS 9119 Cross Pk Dr, Knoxville, TN 37923 USA
[2] Exelon Generat Co, Oyster Creek Nucl Generating Stn, Lanoka Harbor, NJ 08734 USA
关键词
Instrumentation and control; cable condition monitoring; cable-aging management;
D O I
10.1080/00295450.2017.1360716
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
This paper reports the results of in situ cable testing performed at the Oyster Creek Nuclear Generating Station in September 2016 to assess the aging condition of a number of cables as installed in the plant. Despite having been in service for over 40 years, our results found that these cables still met their qualification criteria, were in good working condition, and could continue to serve the plant for the foreseeable future. Some degradation in the cable insulation was noted but not as much as one would expect after more than 40 years of service in a nuclear power plant. Specifically, test results revealed that 10% of cables exhibited a noticeable degree of degradation, 30% were only slightly degraded, and the remaining 60% were essentially unaffected by aging. In the case of jacketed cables, which were assessed using walkdowns performed by the plant's personnel, almost all aging and degradation were limited to the jacket material while the underlying cable insulation was largely unaffected. This is consistent with laboratory test results, which have shown that jacket material, especially Neoprene and Hypalon, degrade much faster than cross-linked polyethylene (XLPE) and other materials that are used for primary cable insulation.
引用
收藏
页码:93 / 105
页数:13
相关论文
共 41 条
  • [31] Research on Condition Monitoring Technology for Nuclear Power Plant Equipment Based on Kernel Principal Component Analysis
    Wu, Tianhao
    Liu, Tao
    Shi, Haining
    Zhang, Tao
    Tang, Tang
    [J]. Hedongli Gongcheng/Nuclear Power Engineering, 2020, 41 (05): : 132 - 137
  • [32] Condition monitoring as a key technology - An analysis of requirements for new business models for remote services
    Voigt, Kai-Ingo
    Steinmann, Florian
    Bauer, Joerg
    Dremel, Alexander
    [J]. VORAUSSCHAU UND TECHNOLOGIEPLANUNG, 2013, 318 : 369 - 395
  • [33] Research on Monitoring Technology of Unprotected Cross-Area Access Behavior in New Energy Station
    Li, Qiang
    Liu, Bo
    Qiu, Tian
    Guo, Qian
    [J]. 2019 INTERNATIONAL CONFERENCE ON INTERNET OF THINGS (ITHINGS) AND IEEE GREEN COMPUTING AND COMMUNICATIONS (GREENCOM) AND IEEE CYBER, PHYSICAL AND SOCIAL COMPUTING (CPSCOM) AND IEEE SMART DATA (SMARTDATA), 2019, : 441 - 449
  • [34] BIG-BROWN-GENERATING-STATION - NEW-TECHNOLOGY FABRIC FILTER IS CHOICE AT LIGNITE-FIRED PLANT
    PAFIMENI, SR
    MCKENNA, TA
    [J]. POWER, 1994, 138 (04) : 93 - 95
  • [35] "Proryv" project: Inherent safety principles implementation in a new technology platform of the nuclear power industry
    Adamov, Evgeniy
    Rachkov, Valeriy
    [J]. NUCLEAR ENGINEERING AND DESIGN, 2021, 384
  • [36] Implementation of new monitoring tools and optimisation of maintenance through the use of web-based technology
    Jung, T
    Tenbohlen, S
    Altwegg, J
    Roussel, P
    Harfouch, C
    [J]. 2004 IEEE/PES TRANSMISSION & DISTRIBUTION CONFERENCE & EXPOSITION: LATIN AMERICA, 2004, : 902 - 907
  • [37] EXPERIENCE WITH THE IMPLEMENTATION OF NUREG-0292, NUCLEAR-POWER PLANT LICENSING - OPPORTUNITIES FOR IMPROVEMENT ON THE REPLICATION OF PALO-VERDE-NUCLEAR-GENERATING-STATION, UNITS 1,2, AND 3
    ALLEN, JM
    KARNER, DB
    [J]. TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1979, 32 (JUN): : 606 - 606
  • [38] A High-Efficiency Security Monitoring Technology for New Energy Plant Station Network Border with Flow Characteristics Design
    Zhao, Jinxiong
    Bai, Jing
    Li, Zhiru
    Zhang, Xun
    Zhu, Xiaoqin
    Bai, Runqing
    [J]. 2018 4TH INTERNATIONAL CONFERENCE ON ENVIRONMENTAL SCIENCE AND MATERIAL APPLICATION, 2019, 252
  • [39] Implementation of Non-Destructive Condition Monitoring Techniques on Low-Voltage Nuclear Cables: II. Thermal Aging of EPR/CSPE Cables
    Mustafa, Ehtasham
    Afia, Ramy S. A.
    Nawaz, Aamir
    Nouini, Oumaima
    Tamus, Zoltan Adam
    [J]. ENERGIES, 2022, 15 (09)
  • [40] Implementation of Non-Destructive Electrical Condition Monitoring Techniques on Low-Voltage Nuclear Cables: I. Irradiation Aging of EPR/CSPE Cables
    Mustafa, Ehtasham
    Afia, Ramy S. A.
    Nouini, Oumaima
    Tamus, Zoltan Adam
    [J]. ENERGIES, 2021, 14 (16)