Independent external validation of predictive models for urinary dysfunction following external beam radiotherapy of the prostate: Issues in model development and reporting

被引:5
|
作者
Yahya, Noorazrul [1 ,2 ]
Ebert, Martin A. [1 ,3 ]
Bulsara, Max [4 ]
Kennedy, Angel [3 ]
Joseph, David J. [3 ,5 ]
Denham, James W. [6 ]
机构
[1] Univ Western Australia, Sch Phys, Crawley, WA 6009, Australia
[2] Natl Univ Malaysia, Sch Hlth Sci, Bangi, Malaysia
[3] Sir Charles Gairdner Hosp, Dept Radiat Oncol, Nedlands, WA, Australia
[4] Univ Notre Dame, Inst Hlth Res, Fremantle, WA, Australia
[5] Univ Western Australia, Sch Surg, Nedlands, WA 6009, Australia
[6] Univ Newcastle, Sch Med & Publ Hlth, Callaghan, NSW 2308, Australia
基金
英国医学研究理事会;
关键词
Independent external validation; Predictive model; Prostate radiotherapy; Normal tissue complications; Urinary symptoms; TROG; 03.04; RADAR; INTENSITY-MODULATED RADIOTHERAPY; SINGLE NUCLEOTIDE POLYMORPHISMS; GENOME-WIDE ASSOCIATION; RADIATION-THERAPY; CANCER PATIENTS; GASTROINTESTINAL TOXICITY; MULTIVARIABLE MODELS; ANDROGEN SUPPRESSION; CLINICAL FACTORS;
D O I
10.1016/j.radonc.2016.05.010
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background and purpose: Most predictive models are not sufficiently validated for prospective use. We performed independent external validation of published predictive models for urinary dysfunctions following radiotherapy of the prostate. Materials/methods: Multivariable models developed to predict atomised and generalised urinary symptoms, both acute and late, were considered for validation using a dataset representing 754 participants from the TROG 03.04-RADAR trial. Endpoints and features were harmonised to match the predictive models. The overall performance, calibration and discrimination were assessed. Results: 14 models from four publications were validated. The discrimination of the predictive models in an independent external validation cohort, measured using the area under the receiver operating characteristic (ROC) curve, ranged from 0.473 to 0.695, generally lower than in internal validation. 4 models had ROC >0.6. Shrinkage was required for all predictive models' coefficients ranging from -0.309 (prediction probability was inverse to observed proportion) to 0.823. Predictive models which include baseline symptoms as a feature produced the highest discrimination. Two models produced a predicted probability of 0 and 1 for all patients. Conclusions: Predictive models vary in performance and transferability illustrating the need for improvements in model development and reporting. Several models showed reasonable potential but efforts should be increased to improve performance. Baseline symptoms should always be considered as potential features for predictive models. (C) 2016 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:339 / 345
页数:7
相关论文
共 50 条
  • [41] Risk of mesothelioma following external beam radiotherapy for prostate cancer: a cohort analysis of SEER database
    Farioli, Andrea
    Violante, Francesco Saverio
    Mattioli, Stefano
    Curti, Stefania
    Kriebel, David
    CANCER CAUSES & CONTROL, 2013, 24 (08) : 1535 - 1545
  • [42] Recurrent prostate cancer following external beam radiotherapy: Follow-up strategies and management
    Catton, C
    Milosevic, M
    Warde, P
    Bayley, A
    Crook, J
    Bristow, R
    Gospodarowicz, M
    UROLOGIC CLINICS OF NORTH AMERICA, 2003, 30 (04) : 751 - +
  • [43] Lower urinary tract symptoms and urodynamic changes after external beam radiotherapy for localized prostate carcinoma
    Herschorn, S
    Choo, R
    Do, V
    Danjoux, C
    Deboer, G
    Preiner, J
    Morton, G
    Chen, CH
    Barak, I
    JOURNAL OF UROLOGY, 2002, 167 (04): : 199 - 200
  • [44] Development and external validation of a predictive nomogram model of posttraumatic epilepsy: A retrospective analysis
    Wang, Xue-Ping
    Zhong, Jie
    Lei, Ting
    Wang, Hai-Jiao
    Zhu, Li-Na
    Chu, Shanshan
    Chen, Deng
    Liu, Ling
    SEIZURE-EUROPEAN JOURNAL OF EPILEPSY, 2021, 88 : 36 - 44
  • [45] Patient-Reported Outcomes through Five Years following External Beam Radiotherapy or External Beam Radiotherapy with Low-Dose-Rate Brachytherapy Boost for Localized Prostate Cancer
    Pasalic, D.
    Barocas, D. A.
    Zhao, Z.
    Huang, L. C.
    Koyama, T.
    Tang, C.
    Penson, D. F.
    Hoffman, K. E.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2020, 108 (03): : S68 - S68
  • [46] Salvage helical tomotherapy for prostate cancer recurrence following definitive external beam radiotherapy: A case report
    Lee, Sang Hyub
    Jung, Jinhong
    Chang, Sung-Goo
    ONCOLOGY LETTERS, 2015, 10 (02) : 1044 - 1046
  • [47] Modification and validation of an analytical source model for external beam radiotherapy Monte Carlo dose calculations
    Davidson, Scott E.
    Cui, Jing
    Kry, Stephen
    Deasy, Joseph O.
    Ibbott, Geoffrey S.
    Vicic, Milos
    White, R. Allen
    Followill, David S.
    MEDICAL PHYSICS, 2016, 43 (08) : 4842 - 4853
  • [48] External Beam Radiotherapy for Prostate Cancer: Urinary Outcomes for Men With High International Prostate Symptom Scores (IPSS) Editorial Comment
    Walsh, Patrick C.
    JOURNAL OF UROLOGY, 2011, 185 (03): : 896 - 896
  • [49] External Validation of a Predictive Model of Urethral Strictures for Prostate Patients Treated With HDR Brachytherapy Boost
    Panettieri, Vanessa
    Rancati, Tiziana
    Onjukka, Eva
    Ebert, Martin A.
    Joseph, David J.
    Denham, James W.
    Steigler, Allison
    Millar, Jeremy L.
    FRONTIERS IN ONCOLOGY, 2020, 10
  • [50] Optimal radiotherapy for prostate cancer: Predictions for conventional external beam, IMRT, and brachytherapy from radiobiologic models
    King, CR
    DiPetrillo, TA
    Wazer, DE
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2000, 46 (01): : 165 - 172