Palliation Plus Ventricular Assist Device Insertion in 15 Neonates and Infants With Functionally Univentricular Circulation

被引:10
|
作者
Bleiweis, Mark S. [1 ]
Philip, Joseph [1 ]
Peek, Giles J. [1 ]
Fudge, James C. [1 ]
Sullivan, Kevin J. [1 ]
Co-Vu, Jennifer [1 ]
Gupta, Dipankar [1 ]
Shih, Renata [1 ]
Pietra, Biagio 'Bill' A. [1 ]
Fricker, Frederick Jay [1 ]
Vyas, Himesh V. [1 ]
Hernandez-Rivera, Jose F. [1 ]
Powers, Emma R. [1 ]
Nixon, Connie S. [1 ]
Falasa, Matheus [1 ]
Jacobs, Jeffrey Phillip [1 ]
机构
[1] Univ Florida, Congenital Heart Ctr, Gainesville, FL USA
来源
ANNALS OF THORACIC SURGERY | 2022年 / 114卷 / 04期
关键词
D O I
10.1016/j.athoracsur.2022.02.051
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND We report 15 high-risk neonates and infants with functionally univentricular circulation stabilized with initial surgical palliation plus ventricular assist device (VAD) insertion (PALLIATION+VAD) in preparation for transplantation.METHODS Fifteen functionally univentricular patients with ductal-dependent systemic circulation (8 hypoplastic left heart syndrome, 1 hypoplastic left heart syndrome-related malformation: 7 neonates, 2 infants) or ductal-dependent pulmonary circulation (6 hypoplastic right heart syndrome: 5 neonates, 1 infant) presented with anatomical and/or physiological features associated with increased risk for conventional univentricular palliation (large coronary sinusoids with ventricular-dependent coronary circulation, severe systemic atrioventricular valvar regurgitation, cardiogenic shock, or restrictive atrial septum). PALLIATION+VAD for patients with ductal-dependent systemic circulation was: VAD insertion plus application of bilateral pulmonary bands, stent placement in the arterial duct, and atrial septectomy, if needed. PALLIATION+VAD for patients with ductal-dependent pulmonary circulation was: VAD insertion plus stent placement in the arterial duct or systemic-to-pulmonary artery shunt with pulmonary arterioplasty, if needed.RESULTS At PALLIATION+VAD, median age was 20 days (range, 4-143 days) and median weight was 3.47 kg (range, 2.43-4.86 kg). Ten patients (67%) survived and 5 patients (33%) died. All ten survivors are at home doing well after successful transplantation. Only 2 of 10 survivors (20%) required intubation > 10 days after PALLIATION+VAD. Median length of VAD support for all 15 patients was 138 days (range, 56-226 days).CONCLUSIONS High-risk neonates with functionally univentricular hearts who are suboptimal candidates for conventional palliation can be successfully stabilized with pulsatile VAD insertion along with initial palliation while awaiting cardiac transplantation; these patients may be extubated, enterally nourished, and optimized for transplantation while on VAD. (Ann Thorac Surg 2022;114:1412-8) (c) 2022 by The Society of Thoracic Surgeons
引用
下载
收藏
页码:1412 / 1418
页数:7
相关论文
共 50 条
  • [21] Timing of Temporary Right Ventricular Assist Device Insertion for Severe Right Heart Failure After Left Ventricular Assist Device Implantation
    Takeda, Koji
    Naka, Yoshifumi
    Yang, Jonathan A.
    Uriel, Nir
    Colombo, Paolo C.
    Jorde, Ulrich P.
    Takayama, Hiroo
    ASAIO JOURNAL, 2013, 59 (06) : 564 - 569
  • [22] Unplanned left ventricular assist device insertion for dissecting intramyocardial hematoma during biventricular assist device explantation
    Dimarakis, Ioannis
    Hayes, Tim
    Venkateswaran, Rajamiyer
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2018, 155 (02): : E63 - E65
  • [23] A minimally invasive right ventricular assist device insertion late after a continuous-flow left ventricular assist device implantation
    Ando, Masahiko
    Hiroo, Takayama
    Naka, Yoshifumi
    Takeda, Koji
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2018, 155 (01): : E41 - E43
  • [24] Insertion of durable left ventricular assist device with repair of ischemic ventricular septal rupture
    Hirani, Rahim
    Ohira, Suguru
    Spielvogel, David
    De La Pena, Corazon
    Kai, Masashi
    JOURNAL OF CARDIAC SURGERY, 2022, 37 (11) : 3896 - 3898
  • [25] The Effect of Standardization of Insertion and Removal of Percutaneous Left Ventricular Assist Device
    Lee, J.
    Matsukage, H.
    Gondi, S.
    Gifft, K.
    Wang, J.
    Bhattad, V.
    Bavishi, C.
    Karuparthi, P. R.
    Kumar, A.
    Chan, A.
    Hirai, T.
    JACC-CARDIOVASCULAR INTERVENTIONS, 2024, 17 (04) : S62 - S62
  • [26] Rectus-Sparing Technique for Driveline Insertion of Ventricular Assist Device
    Asaki, S. Yukiko
    McKenzie, E. Dean
    Elias, Barbara
    Adachi, Iki
    ANNALS OF THORACIC SURGERY, 2015, 100 (05): : 1920 - 1922
  • [27] PROSTHETIC ABDOMINAL FASCIAL CLOSURE AFTER VENTRICULAR ASSIST DEVICE INSERTION
    DOWNEY, RJ
    OZ, MC
    PEPINO, P
    ROSE, EA
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 1995, 14 (04): : 788 - 789
  • [28] Management of Vasoplegic Shock in Left Ventricular Assist Device Insertion Procedures
    Chatterjee, Subhasis
    TEXAS HEART INSTITUTE JOURNAL, 2023, 50 (04)
  • [29] Technique for insertion of the inflow cannula of the INCOR left ventricular assist device
    Komoda, Takeshi
    Weng, Yuguo
    Hetzer, Roland
    ANNALS OF THORACIC SURGERY, 2008, 85 (04): : 1466 - 1467
  • [30] Tricuspid Valve Repair during Left Ventricular Assist Device Insertion
    Koeckert, M.
    Comas, G.
    Yang, J.
    Lippel, M.
    Uriel, N.
    Takayama, H.
    Naka, Y.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2011, 30 (04): : S43 - S44