Evaluation of semi-automatic 3D reconstruction for studying geometry of dendritic spines

被引:8
|
作者
Al-Absi, Abdel-Rahman [1 ,2 ]
Christensen, Heidi Sogaard [2 ,3 ]
Sanchez, Connie [4 ,5 ]
Nyengaard, Jens Randel [1 ,2 ]
机构
[1] Aarhus Univ, Core Ctr Mol Morphol, Sect Stereol & Microscopy, Dept Clin Med, Aarhus, Denmark
[2] Aarhus Univ, Ctr Stochast Geometry & Adv Bioimaging, Aarhus, Denmark
[3] Aalborg Univ, Dept Math Sci, Aalborg, Denmark
[4] Alkermes, Waltham, MA USA
[5] Aarhus Univ, Dept Clin Med, Translat Neuropsychiat Unit, Aarhus, Denmark
关键词
Golgi staining; Semi-automatic method; Spine reconstruction; TOOL;
D O I
10.1016/j.jchemneu.2018.10.008
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Background: Spine geometry is considered to reflect synapse function. An accurate and fast method for 3D reconstruction of spines is considered a valuable tool for the purpose of studying spine geometry. Currently, most studies employ manual or automatic reconstruction methods, which still suffer from either poor accuracy or extreme time-consumption. The semi-automatic reconstruction method has previously been described as a time-economic and accurate tool for spine number counting. The purpose of this study is to further validate the semi-automatic method with regards to spine geometry investigation, by comparing it with the manual method as well as with the automatic method. Methods: In this study, dendritic trees of six pyramidal neurons that belong to layers II/III of mouse frontal cortex are stained using the Golgi method. Thereafter, spines from 42 dendritic branches are 3D reconstructed by manual, semi-automatic and automatic methods using Imaris software. Spine features, including spine volume, spine area, spine length and spine neck length, and the relative distribution of classified stubby, mushroom and thin spines are compared between the semi-automatic method and the two other methods. Results: Results from the semi-automatic and the manual reconstruction methods are in line with respect to all measured spine geometric features as well as spine classes. However, significant difference has been detected between the two methods and the automatic method in spine length, spine neck length and spine volume. Compared to the manual method, both the semi-automatic and the automatic methods have significantly reduced the spine reconstruction time. Conclusion: These findings suggest that the semi-automatic method may represent both a time-economic and reliable option for the purpose of studying spine geometry.
引用
收藏
页码:119 / 124
页数:6
相关论文
共 50 条
  • [21] Semi-Automatic Registration of 3D Orthodontics Models from Photographs
    Destrez, Raphael
    Treuillet, Sylvie
    Lucas, Yves
    Albouy-Kissi, Benjamin
    MEDICAL IMAGING 2013: IMAGE PROCESSING, 2013, 8669
  • [22] Semi-Automatic Assessment of Pediatric Hydronephrosis Severity in 3D Ultrasound
    Cerrolaza, Juan J.
    Otero, Hansel
    Yao, Peter
    Biggs, Elijah
    Mansoor, Awais
    Ardon, Roberto
    Jago, James
    Peters, Craig A.
    Linguraru, Marius George
    MEDICAL IMAGING 2016: COMPUTER-AIDED DIAGNOSIS, 2015, 9785
  • [23] Comparative Analysis of Terrestrial Semi-automatic and Automatic Photogrammetry in 3D Modeling Process
    Sonja Krasić
    Petar Pejić
    Nexus Network Journal, 2014, 16 : 273 - 283
  • [24] Comparative Analysis of Terrestrial Semi-automatic and Automatic Photogrammetry in 3D Modeling Process
    Krasic, Sonja
    Pejic, Petar
    NEXUS NETWORK JOURNAL, 2014, 16 (02) : 273 - 283
  • [25] From Point Clouds to Building Information Models: 3D Semi-Automatic Reconstruction of Indoors of Existing Buildings
    Macher, Helene
    Landes, Tania
    Grussenmeyer, Pierre
    APPLIED SCIENCES-BASEL, 2017, 7 (10):
  • [26] EDIT Software: A tool for the semi-automatic 3D reconstruction of bladder cancer and urinary bladder of animal models
    Andrikos, Ioannis
    Stefanou, Kostas
    Bellos, Christos
    Stergios, George
    Alchera, Elisa
    Locatelli, Irene
    Alfano, Massimo
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2023, 232
  • [27] Automatic 3D Ear Reconstruction Based on Epipolar Geometry
    Sun, Chao
    Mu, Zhi-chun
    Zeng, Hui
    PROCEEDINGS OF THE FIFTH INTERNATIONAL CONFERENCE ON IMAGE AND GRAPHICS (ICIG 2009), 2009, : 496 - 500
  • [28] A novel method for semi-automatic 2D to 3D video conversion
    Wu, Chenglei
    Er, Guihua
    Xie, Xudong
    Li, Tao
    Cao, Xun
    Dai, Qionghai
    2008 3DTV-CONFERENCE: THE TRUE VISION - CAPTURE, TRANSMISSION AND DISPLAY OF 3D VIDEO, 2008, : 45 - 48
  • [29] A Simple Semi-automatic Technique for 2D to 3D Video Conversion
    Chen, Jun
    Zhao, Jianhui
    Wang, Xiaomao
    Huang, Chuanhe
    Dong, Erqian
    Chen, Bingyu
    Yuan, Zhiyong
    ARTIFICIAL INTELLIGENCE AND COMPUTATIONAL INTELLIGENCE, PT II, 2011, 7003 : 336 - 343
  • [30] Robust 3D reconstruction and identification of dendritic spines from optical microscopy imaging
    Janoos, Firdaus
    Mosaliganti, Kishore
    Xu, Xiaoyin
    Machiraju, Raghu
    Huang, Kun
    Wong, Stephen T. C.
    MEDICAL IMAGE ANALYSIS, 2009, 13 (01) : 167 - 179