Evaluation of the Sysmex UF-1000i® urine flow cytometer in the diagnostic work-up of suspected urinary tract infection in a Dutch general hospital

被引:38
|
作者
van der Zwet, Wil C. [1 ]
Hessels, Jan [2 ]
Canbolat, Fatih [1 ]
Deckers, Martine M. L. [2 ]
机构
[1] Deventer Hosp, Dept Med Microbiol & Infect Control, NL-7400 GC Deventer, Netherlands
[2] Deventer Hosp, Dept Clin Chem, NL-7400 GC Deventer, Netherlands
关键词
flow cytometry; Sysmex UF-1000i; urinary tract infection; AUTOMATED URINALYSIS; SEDIMENT EXAMINATION; TEST STRIPS; MICROSCOPY; PERFORMANCE; ANALYZER;
D O I
10.1515/CCLM.2010.342
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: Automation and standardization of sediment analysis of urine samples by flow cytometry might serve as an alternative to labor-intensive laboratory methods, such as microscopic examination and culture. The Sysmex UF-1000i is a urine flow cytometer that uses two separate channels for counting blood cells and bacteria. Methods: In this study, 358 urine samples were analyzed with the Sysmex UF-1000i in parallel with manual microscopy, Gram stain and bacterial culture, the latter considered the gold standard. Results: Reproducibility for detection of white and red blood cells and bacteria was good, while detection of yeast proved unreliable. Depending on the definition of urinary tract infection (UTI) used, the negative predictive value and the percentage of false-negative results were 100% and 0% [UTI >= 10(5) colony forming units (CFU)/mL] and 99% and 1.3%, (UTI >= 10(4) CFU/mL), respectively. Pre-screening with the Sysmex UF-1000i would have resulted in a reduction of bacterial culture by 42%. Carry over of bacteria between consecutive samples due to the use of fixed sample needle was observed, but did not result in false-positive interpretation of Sysmex UF-1000i results. Because of the occurrence of carry over, samples that have been analyzed with the Sysmex UF-1000i cannot be used for subsequent urine culture. Conclusions: In conclusion, the Sysmex UF-1000i offers the possibility for screening high numbers of urine samples in a fast and standardized way, resulting in a reduction in workload and speeding the diagnostic process. It is not recommended for use in complicated patient populations, such as neutropenic patients and patients in whom yeast infection is suspected. Clin Chem Lab Med 2010; 48:1765-71.
引用
收藏
页码:1765 / 1771
页数:7
相关论文
共 33 条
  • [21] Evaluation of Sysmex UF-1000i® flow cytometer as a screening method for asymptomatic bacteriuria and detection of Group B Streptococcus in pregnancy
    Angulo Lopez, Itziar
    Urrutikoetxea-Gutierrez, Mikel
    Aragon-Diez, Julia
    Fraca Padilla, Mercedes
    de Tuesta Del Arco, Jose Luis Diaz
    REVISTA ESPANOLA DE QUIMIOTERAPIA, 2020, 33 (03) : 193 - 199
  • [22] Using the Sysmex UF-4000 urine flow cytometer for rapid diagnosis of urinary tract infection in the clinical microbiological laboratory
    Korsten, Koos
    de Gier, Astrid
    Leenders, Alexander
    Wever, Peter C.
    Kolwijck, Eva
    JOURNAL OF CLINICAL LABORATORY ANALYSIS, 2024, 38 (05)
  • [23] Age-Specific Cutoffs of the Sysmex UF-1000i Automated Urine Analyzer for Rapid Screening of Urinary Tract Infections in Outpatients
    Kim, Hyunji
    Kim, Hye Ryoun
    Kim, Tae-Hyoung
    Lee, Mi-Kyung
    ANNALS OF LABORATORY MEDICINE, 2019, 39 (03) : 322 - 326
  • [24] Evaluation of Sysmex UF-5000 flow cytometer flag BACT-info for Gram discrimination in urinary tract infection
    Angulo-Lopez, Itziar
    Martin-Corujo, Dario
    Luis Diaz-de-Tuesta del Arco, Jose
    Basaras-Ibarzabal, Miren
    REVISTA ESPANOLA DE QUIMIOTERAPIA, 2024, 37 (01) : 52 - 57
  • [25] Flow Cytometry Analysis Using Sysmex UF-1000i Classifies Uropathogens Based on Bacterial, Leukocyte, and Erythrocyte Counts in Urine Specimens among Patients with Urinary Tract Infections
    Monsen, Tor
    Ryden, Patrik
    JOURNAL OF CLINICAL MICROBIOLOGY, 2015, 53 (02) : 539 - 545
  • [26] High false positive rate of white blood cells in urine samples of pregnant women may be caused by epithelial cells being misclassified by the sysmex UF-1000i urine flow cytometer
    Yang, Wei
    Yu, Xiaochen
    Liu, Dan
    Guan, Xiuru
    CYTOMETRY PART B-CLINICAL CYTOMETRY, 2019, 96 (06) : 464 - 468
  • [27] Evaluation of the Sysmex UF-4000i urine analyzer as a screening test to rule out urinary tract infection and reduce urine cultures
    El Kettani, Assiya
    Housbane, Samy
    Wakit, Fatima
    Mikou, Karima Arioua
    Belabbes, Houria
    Zerouali, Khalid
    ANNALES DE BIOLOGIE CLINIQUE, 2023, 81 (02) : 156 - 161
  • [28] COMPARING THE PERFORMANCE OF THE NEW LASER FLOW CYTOMETER UF-5000 WITH UF-1000I AND GRAM STAIN IN PREDICTING BACTERIA GROWTH PATTERNS IN WOMEN WITH UNCOMPLICATED URINARY TRACT INFECTIONS
    Wang, S.
    Chang, S.
    Yang, C.
    Chen, Y.
    Yang, S.
    NEUROUROLOGY AND URODYNAMICS, 2020, 39 : S434 - S435
  • [29] Evaluation and optimization of the Sysmex UF1000i system for the screening of urinary tract infection in primary health care elderly patients
    Martin-Gutierrez, Guillermo
    Porras-Gonzalez, Ana
    Martin-Perez, Carlos
    Antonio Lepe, Jose
    Aznar, Javier
    ENFERMEDADES INFECCIOSAS Y MICROBIOLOGIA CLINICA, 2015, 33 (05): : 320 - 323
  • [30] Prediction of presence of fastidious bacteria by the Fully Automated Urine Particle Analyzer UF-1000i in the case of ineffective antimicrobial therapy for urinary tract infection
    Kaido, Masako
    Yasuda, Mitsuru
    Komeda, Hisao
    Okano, Manabu
    Ito, Yasuhisa
    Ohashi, Hazuki
    Ohta, Hirotoshi
    Akai, Yasumasa