Label-Free Quartz Crystal Microbalance Biosensor Based on Aptamer-Capped Gold Nanocages Loaded with Polyamidoamine for Thrombin Detection

被引:16
|
作者
Xi, Xinge [1 ]
Niyonshuti, Isabelle I. [2 ]
Yu, Ningxiang [3 ,4 ]
Yao, Lan [3 ]
Fu, Ying [3 ]
Chen, Jingyi [2 ]
Li, Yanbin [1 ,3 ]
机构
[1] Univ Arkansas, Dept Biol & Agr Engn, Fayetteville, AR 72701 USA
[2] Univ Arkansas, Dept Chem & Biochem, Fayetteville, AR 72701 USA
[3] Univ Arkansas, Ctr Excellence Poultry Sci, Fayetteville, AR 72701 USA
[4] Zhejiang Univ Technol, Coll Food Sci & Technol, Hangzhou 310014, Peoples R China
关键词
QCM biosensor; thrombin detection; gold nanocages; thrombin aptamers; target-triggered release; ULTRASENSITIVE DETECTION; CONTROLLED-RELEASE; ELECTROCHEMICAL APTASENSOR; AU NANOCAGES; NANOPARTICLES; RESONANCE; QCM;
D O I
10.1021/acsanm.1c01350
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Thrombin is an important biomarker, and its detection is of great significance for diagnosis and prevention of related diseases. Conventional methods such as enzyme-linked immunosorbent assay are sensitive but require multiple steps. In this work, a label-free biosensor that only required one step of incubation was developed based on target-triggered release of the cargo molecules from gold nanocages, which achieved highly sensitive and specific detection of thrombin. The proposed biosensor consists of an array of gold nanocages loaded with molecules in their interiors and the DNA probes immobilized on their surface for hybridization with thrombin-specific aptamers to seal their pores. Upon interaction with thrombin, the surface aptamers were lifted off the gold nanocages, resulting in release of the cargo molecules. The loss of cargo molecules was detected by quartz crystal microbalance (QCM). The signal could be amplified by the choice of cargo molecules. The use of polyamidoamine as cargo molecules allowed us to achieve a label-free biosensor with a linear detection range of 0.0086-86 nM and a limit of detection of 7.7 pM. The biosensor was also tested with spiked human serum samples with a limit of detection of 1.2 nM. The detection could be carried out within 1.5 h with only one incubation step of 45 min. The specificity of the biosensor was confirmed by testing against bovine serum albumin and lysozyme at 1 mu M.
引用
收藏
页码:10047 / 10054
页数:8
相关论文
共 50 条
  • [11] Label-free aptamer biosensor for thrombin detection on a nanocomposite of graphene and plasma polymerized allylamine
    Zhang, Zhihong
    Liu, Shunli
    Shi, Yu
    Zhang, Yuanchang
    Peacock, Dave
    Yan, Fufeng
    Wang, Peiyuan
    He, Linghao
    Feng, Xiaozhong
    Fang, Shaoming
    [J]. JOURNAL OF MATERIALS CHEMISTRY B, 2014, 2 (11) : 1530 - 1538
  • [12] Sensitive label-free immunoglobulin G detection using a MEMS quartz crystal microbalance biosensor with a 125 MHz wireless quartz resonator
    Zhou, Lianjie
    Kato, Fumihito
    Ogi, Hirotsugu
    [J]. JAPANESE JOURNAL OF APPLIED PHYSICS, 2021, 60 (SD)
  • [13] Electrochemical aptamer biosensor for DNA detection based on label-free aptamers
    Li, Li
    Chen, Zhengbo
    [J]. BIOELECTROCHEMISTRY, 2023, 153
  • [14] Aptamer-Based Label-Free Impedimetric Biosensor for Detection of Progesterone
    Jimenez, Gaston Contreras
    Eissa, Shimaa
    Ng, Andy
    Alhadrami, Hani
    Zourob, Mohammed
    Siaj, Mohamed
    [J]. ANALYTICAL CHEMISTRY, 2015, 87 (02) : 1075 - 1082
  • [15] Development of label-free fluorescent biosensor for the detection of kanamycin based on aptamer capped metal-organic framework
    Liu, Shanshan
    Chen, Yanmei
    Ruan, Zhijun
    Lin, Junqi
    Kong, Wen
    [J]. ENVIRONMENTAL RESEARCH, 2022, 206
  • [16] An aptamer-based quartz crystal microbalance biosensor for sensitive and selective detection of leukemia cells using silver-enhanced gold nanoparticle label
    Shan, Wenqian
    Pan, Yuliang
    Fang, Heting
    Guo, Manli
    Nie, Zhou
    Huang, Yan
    Yao, Shouzhuo
    [J]. TALANTA, 2014, 126 : 130 - 135
  • [17] Label-free impedimetric biosensor for thrombin using the thrombin-binding aptamer as receptor
    Frense, D.
    Kang, S.
    Schieke, K.
    Reich, P.
    Barthel, A.
    Pliquett, U.
    Nacke, T.
    Brian, C.
    Beckmann, D.
    [J]. XV INTERNATIONAL CONFERENCE ON ELECTRICAL BIO-IMPEDANCE (ICEBI) & XIV CONFERENCE ON ELECTRICAL IMPEDANCE TOMOGRAPHY (EIT), 2013, 434
  • [18] Sensitive and Label-free Detection of Cartilage Oligomeric Matrix Protein on Quartz Crystal Microbalance
    Shen, C. Y.
    Wu, C. L.
    Lin, Y. M.
    Hwang, R. C.
    [J]. INTERNATIONAL CONFERENCE ON COMPUTER SCIENCE AND ENVIRONMENTAL ENGINEERING (CSEE 2015), 2015, : 920 - 926
  • [19] Aptamer-capped nanocrystal quantum dots: A new method for label free protein detection
    Choi, Jong Hyun
    Chen, Kok Hao
    Strano, Michael S.
    [J]. ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2007, 233
  • [20] Label-Free Real-Time Detection of DNA Methylation Based on Quartz Crystal Microbalance Measurement
    Wang, Jie
    Zhu, Zhiqiang
    Ma, Hongwei
    [J]. ANALYTICAL CHEMISTRY, 2013, 85 (04) : 2096 - 2101