Dose verification for rotating multileaf collimator IMRT

被引:0
|
作者
Schmuland, M
Otto, K
机构
[1] Univ British Columbia, Vancouver, BC V5Z 1M9, Canada
[2] British Columbia Canc Agcy, Vancouver, BC V5Z 4E6, Canada
关键词
D O I
10.1118/1.2031055
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A new method of delivering IMRT has been proposed in which the entire MLC is rotated between each segment. Current linacs were not designed for IMRT delivery with collimator rotation and extensive quality assurance testing must be done before it can be used clinically. This work describes the different areas of testing that need to be considered, namely (1) the commissioning and QA of the Dynamic Beam Delivery (DBD) Toolbox (Varian Medical Systems, Palo Alto) required for collimator rotation control on a Varian CL21EX linac, (2) accurate fluence modeling of rotated apertures, and (3) dosimetric verification of full IMRT treatments delivered with a rotating MLC (RMLC). The DBD toolbox was tested and the collimator rotation angle was found to be accurate and reproducible to within 0.5 degrees. Fluence distributions of varying complexity were generated using the RMLC algorithm and the accuracy of the fluence modeling was validated using film based verification methods. IMRT treatment plans for a prostate, nasopharynx, and c‐shape target were generated with the RMLC segmentation algorithm and were delivered to a phantom. Measured and calculated dose distributions were compared using dose difference, distance‐to‐agreement, gamma factor maps and two‐dimensional profiles. The level of agreement was comparable to clinically accepted plans. Our results show that we can accurately control collimator rotation and precisely model fluence distributions generated from rotating MLC apertures. We also show that the RMLC technique is capable of delivering 3D clinical dose distributions accurately and reproducibly. This work was supported in part by Varian Medical Systems. © 2005, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2425 / 2425
页数:1
相关论文
共 50 条
  • [21] A new concept of multileaf collimator (the shuttling MLC) - an interpreter for high-efficiency IMRT
    Webb, S
    PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (11): : 3343 - 3358
  • [22] Sensitivity of 3D Dose Verification to Multileaf Collimator Misalignments in Stereotactic Body Radiation Therapy of Spinal Tumor
    Ni Xin-ye
    Ren, Lei
    Yan, Hui
    Yin, Fang-Fang
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2016, 15 (06) : NP25 - NP34
  • [23] Dose Verification in IMRT and VMAT
    Feygelman, Vladimir
    Nelms, Benjamin E.
    CONCEPTS AND TRENDS IN MEDICAL RADIATION DOSIMETRY, 2011, 1345 : 145 - +
  • [24] Monte Carlo Modeling of the Siemens® ARTISTE™ 160 Multi-leaf Collimator for IMRT dose verification
    Dayyani, M.
    Hoseinian-Azghadi, E.
    Rafat-Motavalli, L.
    Miri-Hakimabad, H.
    Tugrul, T.
    Sobhkhiz-Sabet, L.
    RADIOTHERAPY AND ONCOLOGY, 2023, 182 : S1526 - S1526
  • [25] Dosimetric Verification of Modulated Electron Radiotherapy Delivery Using Photon Multileaf Collimator
    Jin, L.
    Ma, C.
    Eldib, A.
    Fan, J.
    Chi, Z.
    Li, J.
    MEDICAL PHYSICS, 2008, 35 (06)
  • [26] Dose compensation for photon field matching using a multileaf collimator (MLC)
    Alcibar-Arechuluaga, C.
    Pinza-Molina, C.
    Fernandez, S.
    Garcia, Cerezo S.
    Morillas-Perez, M.
    Jimenez, J.
    Chapel, M.
    Tato, F.
    Gonzalez, M.
    RADIOTHERAPY AND ONCOLOGY, 2007, 84 : S285 - S285
  • [27] Verification of multileaf collimator leaf positions using an electronic portal imaging device
    Samant, SS
    Zheng, W
    Parra, NA
    Chandler, J
    Gopal, A
    Wu, J
    Jain, J
    Zhu, YP
    Sontag, M
    MEDICAL PHYSICS, 2002, 29 (12) : 2900 - 2912
  • [28] validation of Monte Carlo dose calculation algorithm for CyberKnife multileaf collimator
    Gondre, M.
    Marsolat, F.
    Bourhis, J.
    Bochud, F.
    Moeckli, R.
    RADIOTHERAPY AND ONCOLOGY, 2021, 161 : S1362 - S1363
  • [29] Validation of Monte Carlo dose calculation algorithm for CyberKnife multileaf collimator
    Gondre, Maude
    Marsolat, Fanny
    Bourhis, Jean
    Bochud, Francois
    Moeckli, Raphael
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2022, 23 (02):
  • [30] Influence of Collimator Rotation on the Dose Verifications in IMRT Fields
    Kumazaki, Y.
    Kato, A.
    Takamatsu, S.
    Tsukamoto, N.
    Sekine, H.
    MEDICAL PHYSICS, 2011, 38 (06) : 3588 - +