Dose verification for rotating multileaf collimator IMRT

被引:0
|
作者
Schmuland, M
Otto, K
机构
[1] Univ British Columbia, Vancouver, BC V5Z 1M9, Canada
[2] British Columbia Canc Agcy, Vancouver, BC V5Z 4E6, Canada
关键词
D O I
10.1118/1.2031055
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A new method of delivering IMRT has been proposed in which the entire MLC is rotated between each segment. Current linacs were not designed for IMRT delivery with collimator rotation and extensive quality assurance testing must be done before it can be used clinically. This work describes the different areas of testing that need to be considered, namely (1) the commissioning and QA of the Dynamic Beam Delivery (DBD) Toolbox (Varian Medical Systems, Palo Alto) required for collimator rotation control on a Varian CL21EX linac, (2) accurate fluence modeling of rotated apertures, and (3) dosimetric verification of full IMRT treatments delivered with a rotating MLC (RMLC). The DBD toolbox was tested and the collimator rotation angle was found to be accurate and reproducible to within 0.5 degrees. Fluence distributions of varying complexity were generated using the RMLC algorithm and the accuracy of the fluence modeling was validated using film based verification methods. IMRT treatment plans for a prostate, nasopharynx, and c‐shape target were generated with the RMLC segmentation algorithm and were delivered to a phantom. Measured and calculated dose distributions were compared using dose difference, distance‐to‐agreement, gamma factor maps and two‐dimensional profiles. The level of agreement was comparable to clinically accepted plans. Our results show that we can accurately control collimator rotation and precisely model fluence distributions generated from rotating MLC apertures. We also show that the RMLC technique is capable of delivering 3D clinical dose distributions accurately and reproducibly. This work was supported in part by Varian Medical Systems. © 2005, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2425 / 2425
页数:1
相关论文
共 50 条
  • [1] Effects of MLC setting on dose distributions and on multileaf collimator parameters for treatments with IMRT
    Chauvet, I
    Petitfils, A
    Brunet, Y
    Lembrez, R
    Lehobey, C
    Kristner, JY
    Zefkili, S
    Gaboriaud, G
    Mazal, A
    Rosenwald, JC
    RADIOTHERAPY AND ONCOLOGY, 2003, 68 : S36 - S37
  • [2] IMRT delivery performance with a varian multileaf collimator
    Losasso, Thomas
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 71 (01): : S85 - S88
  • [3] The impact of multileaf collimator rotation in IMRT planning
    Roedersheimer, K
    Chen, DZ
    Luan, S
    Xing, L
    MEDICAL PHYSICS, 2005, 32 (06) : 1973 - 1974
  • [4] Multileaf collimator characteristics and reliability requirements for IMRT Elekta system
    Liu, Chihray
    Simon, Thomas A.
    Fox, Christopher
    Li, Jonathan
    Palta, Jatinder R.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 71 (01): : S89 - S92
  • [5] Optimal Multileaf Collimator Leaf Sequencing in IMRT Treatment Planning
    Taskin, Z. Caner
    Smith, J. Cole
    Romeijn, H. Edwin
    Dempsey, James F.
    OPERATIONS RESEARCH, 2010, 58 (03) : 674 - 690
  • [6] Dose computation for a one dimensional multileaf collimator
    Balog, J
    Angelos, L
    Mackie, TR
    Reckwerdt, P
    PROCEEDINGS OF THE XIITH INTERNATIONAL CONFERENCE ON THE USE OF COMPUTERS IN RADIATION THERAPY, 1997, : 434 - 436
  • [7] Dose volume benefits and delivery accuracy of a novel rotating collimator precision IMRT technique
    Otto, K
    Schmuland, M
    RADIOTHERAPY AND ONCOLOGY, 2005, 76 : S106 - S106
  • [8] Monte Carlo dose verification for IMRT plan delivered using micro-multileaf collimators
    Li, JS
    Wang, L
    Chen, L
    Yang, J
    Ma, CM
    MEDICAL PHYSICS, 2004, 31 (06) : 1844 - 1844
  • [9] Communication and sampling rate limitations in IMRT delivery with a dynamic multileaf collimator system
    Xia, P
    Chuang, CF
    Verhey, LJ
    MEDICAL PHYSICS, 2002, 29 (03) : 412 - 423
  • [10] Multileaf collimator end leaf leakage: implications for wide-field IMRT
    Hardcastle, N.
    Metcalfe, P.
    Ceylan, A.
    Williams, M. J.
    PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (21): : N493 - N504